Desa VSGF36PT, VSGF36NT, VSGF36PR, VSGF36NR Set flame adjustment knob to any level between HI and LO

Page 21

OPERATING FIREPLACE

Continued

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, donʼt try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fire- place screen is installed before running fireplace.

NOTICE: During initial operation of new fireplace, burning logs will give off a paper-burning smell. Open damper or window to vent smell. This will only last a few hours.

1.STOP! Read the safety information, start- ing on page 20, column 2.

2.Make sure equipment shutoff valve is fully open.

3.Set selector switch in OFF position.

WARNING: Burners will come on automatically within one minute when the selector switch is in the ON position after the pilot is lit.

4.Press in and turn control knob clockwise to the OFF position.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, page 20. If you donʼt smell gas, go to the next step.

6.Press in and turn control knob counter-

clockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 28).

Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

7.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 22.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 8.

9.Slightly push in and turn control knob coun-

terclockwise to the ON position.

10.Wait one minute and switch selector switch to the ON position to light burners.

11.Set flame adjustment knob to any level between HI and LO.

Ignitor Button

Flame Adjustment

Knob

PI

OT

OL

L

 

 

F

 

O

F

 

O

 

N

 

 

 

 

HI

Selector Switch

Control Knob

Figure 28 - Control Knob and Ignitor

Button Location (Shown as Supplied, No

Control Options)

113192-01B

www.desatech.com

21

Image 21
Contents Models VSGF36NT, VSGF36PT, VSGF36NR and VSGF36PR What to do if YOU Smell GASTable of Contents Safety Information Local Codes Product Features Product IdentificationUnpacking Product Specifications Locating FireboxPlanning Providing Adequate Ventilation AIR for Combustion VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR InstallationVentilation Air From Inside Building Ventilation Air From OutdoorsMinimum Wall and Ceiling Clearances see Figure Installation ClearancesMantel Clearances for Built-In Installation BUILT-IN Firebox InstallationRough Opening Dimensions for Built-in Installation Installing GAS Piping to Fireplace Location Installing Firebox Using Optional Accessory MantelsInstallation Items Needed Natural GasPropane/LP Removing Log Base Assembly From Fireplace Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Fireplace Gas ConnectionsTest Pressures In Excess Of 1/2 Psig KPaGroove Installing Fireplace Hood and Screen HARD-WIRING FireboxThermostat Models For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Remote Control Models For Your Safety Read Before Lighting Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationSet flame adjustment knob to any level between HI and LO Blower Operation Optional HAND-HELD Remote OperationShutting Off Heater Auto Thermostatic Mode Manual ModeAuto Shutoff Feature ON/OFF Series Model GhrcbInspecting Burners Key Pad Lock FeaturePilot Flame Pattern Main BurnerBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceSpecifications Wiring Diagram Replacement PartsTechnical Service Service HintsObserved Problem Possible Cause Remedy TroubleshootingDiagram, See Cleaning and Mainte Shut off gas supply Do not try to light any appliance Accessories Models VSGF36PT, VSGF36NT Illustrated Parts BreakdownParts List Models VSGF36PR, VSGF36NR KEY Part Number VSGF36PR VSGF36NR Description QTY Models VSGF36PT, VSGF36NT, VSGF36PR and VSGF36NR KEY Part Number Description QTY 113192-01B 113192-01B Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS Fireplace

VSGF36PR, VSGF36NR, VSGF36PT, VSGF36NT specifications

The Desa VSGF36NR, VSGF36PT, VSGF36PR, and VSGF36NT are remarkable fireplace solutions that cater to diverse heating needs and aesthetic preferences. Each model is designed to enhance the ambiance of any space while providing efficient warmth.

One of the standout features of these gas fireplaces is their efficiency. They are engineered to provide superior heat output while minimizing gas consumption, making them both eco-friendly and economical. Each unit is equipped with advanced modulation technologies that adjust the flame height based on the room temperature, ensuring optimal heating without wasting fuel.

In terms of design, the Desa models boast a sleek and contemporary aesthetic. The VSGF36NR features a traditional linear design that meshes well with modern interiors. Its large viewing window offers an unobstructed view of the flames, creating a cozy environment. Conversely, the VSGF36PT and VSGF36PR models are designed with a more classical touch, integrating ornate details that enhance the beauty of any room while still maintaining modern functionality.

A key characteristic of these fireplaces is the ease of installation. They come pre-assembled with straightforward installation instructions, allowing homeowners to set them up quickly and conveniently. Additionally, each model can be configured for either vented or vent-free operation, providing versatility based on individual preferences and home requirements.

Convenience is further amplified by remote control options, allowing users to operate the fireplace from the comfort of their seat. The user-friendly interface enables easy temperature adjustments and flame settings. Safety features have also been prioritized; built-in oxygen depletion sensors ensure that the air quality in the room remains safe while the fireplace is in operation.

Another critical aspect of the VSGF series is their ability to integrate seamlessly with smart home technologies. Homeowners can connect their fireplaces to Wi-Fi, allowing for remote monitoring and control via smartphone applications. This ensures that heating can be adjusted from anywhere, adding a layer of modern convenience.

In conclusion, the Desa VSGF36NR, VSGF36PT, VSGF36PR, and VSGF36NT models are not just fireplaces; they are efficient, stylish heating solutions equipped with advanced technology designed for comfort, safety, and convenience. With their blend of design and functionality, these models are an excellent choice for anyone looking to enhance their living space with the warmth and charm of a gas fireplace.