Desa VSGF36PT, VSGF36NT Installation, Ventilation AIR, Ventilation Air From Inside Building

Page 9

AIR FOR COMBUSTION

AND VENTILATION

Continued

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining un- confined space. When ventilating to an adjoining unconfined space, you must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 4). You can also remove door into adjoining room (see option 3, Figure 3). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

 

Outlet

Ventilated

 

Attic

 

Air

 

 

Outlet

 

 

Air

 

To Attic

 

 

 

 

To

 

 

Crawl

Inlet

 

Space

 

 

Air

 

 

 

Inlet Air

Ventilated

 

Crawl Space

 

 

Figure 5 - Ventilation Air from Outdoors

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your

Ventilation

 

Grills

 

Into Adjoining

Or

Room,

Remove

Option 1

Door into

 

 

Adjoining

 

Room,

 

Option

 

3

12"

Ventilation Grills

Into Adjoining Room,

Option 2

primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the

12"

Figure 4 - Ventilation Air from Inside

Building

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat- controlled power vent. Heated air entering the attic will activate the power vent.

house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING:Aqualifiedservice person must install fireplace. Follow all local codes.

WARNING: Never install the fireplace

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing or other flammable objects are less than 42 inches from the front, top or sides of the heater

in high traffic areas

in windy or drafty areas

113192-01B

www.desatech.com

9

Image 9
Contents Models VSGF36NT, VSGF36PT, VSGF36NR and VSGF36PR What to do if YOU Smell GASTable of Contents Safety Information Local Codes Product Features Product IdentificationUnpacking Product Specifications Locating FireboxPlanning Providing Adequate Ventilation AIR for Combustion VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR InstallationVentilation Air From Inside Building Ventilation Air From OutdoorsMinimum Wall and Ceiling Clearances see Figure Installation ClearancesMantel Clearances for Built-In Installation BUILT-IN Firebox InstallationRough Opening Dimensions for Built-in Installation Installing GAS Piping to Fireplace Location Installing Firebox Using Optional Accessory MantelsInstallation Items Needed Natural GasPropane/LP Removing Log Base Assembly From Fireplace Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Fireplace Gas ConnectionsTest Pressures In Excess Of 1/2 Psig KPaGroove Installing Fireplace Hood and Screen HARD-WIRING FireboxThermostat Models For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Remote Control Models For Your Safety Read Before Lighting Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationSet flame adjustment knob to any level between HI and LO Blower Operation Optional HAND-HELD Remote OperationShutting Off Heater Auto Thermostatic Mode Manual ModeAuto Shutoff Feature ON/OFF Series Model GhrcbInspecting Burners Key Pad Lock FeaturePilot Flame Pattern Main BurnerBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceSpecifications Wiring Diagram Replacement PartsTechnical Service Service HintsObserved Problem Possible Cause Remedy TroubleshootingDiagram, See Cleaning and Mainte Shut off gas supply Do not try to light any appliance Accessories Models VSGF36PT, VSGF36NT Illustrated Parts BreakdownParts List Models VSGF36PR, VSGF36NR KEY Part Number VSGF36PR VSGF36NR Description QTY Models VSGF36PT, VSGF36NT, VSGF36PR and VSGF36NR KEY Part Number Description QTY 113192-01B 113192-01B Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS Fireplace

VSGF36PR, VSGF36NR, VSGF36PT, VSGF36NT specifications

The Desa VSGF36NR, VSGF36PT, VSGF36PR, and VSGF36NT are remarkable fireplace solutions that cater to diverse heating needs and aesthetic preferences. Each model is designed to enhance the ambiance of any space while providing efficient warmth.

One of the standout features of these gas fireplaces is their efficiency. They are engineered to provide superior heat output while minimizing gas consumption, making them both eco-friendly and economical. Each unit is equipped with advanced modulation technologies that adjust the flame height based on the room temperature, ensuring optimal heating without wasting fuel.

In terms of design, the Desa models boast a sleek and contemporary aesthetic. The VSGF36NR features a traditional linear design that meshes well with modern interiors. Its large viewing window offers an unobstructed view of the flames, creating a cozy environment. Conversely, the VSGF36PT and VSGF36PR models are designed with a more classical touch, integrating ornate details that enhance the beauty of any room while still maintaining modern functionality.

A key characteristic of these fireplaces is the ease of installation. They come pre-assembled with straightforward installation instructions, allowing homeowners to set them up quickly and conveniently. Additionally, each model can be configured for either vented or vent-free operation, providing versatility based on individual preferences and home requirements.

Convenience is further amplified by remote control options, allowing users to operate the fireplace from the comfort of their seat. The user-friendly interface enables easy temperature adjustments and flame settings. Safety features have also been prioritized; built-in oxygen depletion sensors ensure that the air quality in the room remains safe while the fireplace is in operation.

Another critical aspect of the VSGF series is their ability to integrate seamlessly with smart home technologies. Homeowners can connect their fireplaces to Wi-Fi, allowing for remote monitoring and control via smartphone applications. This ensures that heating can be adjusted from anywhere, adding a layer of modern convenience.

In conclusion, the Desa VSGF36NR, VSGF36PT, VSGF36PR, and VSGF36NT models are not just fireplaces; they are efficient, stylish heating solutions equipped with advanced technology designed for comfort, safety, and convenience. With their blend of design and functionality, these models are an excellent choice for anyone looking to enhance their living space with the warmth and charm of a gas fireplace.