Desa VMH26TPB 14 installation manual Install the switch plate on the valve

Page 12

® VMH26TPB

COMPACT CLASSIC HEARTH® FIREPLACE

INSTALLATION

Continued

4.Carefully disconnect green and white wires at their insulated connectors.

5.In top of the heater cabinet, locate the four mounting holes on the outer cas- ing. Align these four holes with those on the blower bracket assembly. Attach blower bracket assembly to the outer casing with 4 #10 screws provided (see Figure 18).

6.Route the wire harness through the hole in left side of baffle. Pull wire harness through lower opening above where the valve shield was removed. (see Figure 18).

7.Insert the 4 wire harness into one of the round holes in the rear of the valve cover shield and through the rectangular hole in the front of shield (see Figure 18).

8.Reconnect red wire to switch position 3. Reconnect blue wire to switch posi- tion 1. Reconnect green and white wires.

9. Install the switch plate on the valve

cover shield with 2 #10 screws provided

(see Figure 18). Reinstall the valve

cover shield. Route power cord out of

the cabinet by inserting it through the

bushing on the outer casing (see Fig-

ure 18). Plug fan kit into 120-Volt

grounded power supply and test opera-

tion. Note: When switch is in the

AUTO position, the fan will start after

the heater has run for a few moments.

The fan will continue to run for several

moments after the heater has been

turned off. When switch is in the ON

Wiring Routing

Blower BracketHole in Baffle

Assembly

Screw

Baffle

Wire

SwitchHarness

position, the fan will run until turned

to OFF. Reinstall upper louver assem-

bly and hood if previously removed,

(see Figure 16, page 11). Close lower

louver door.

Valve Cover

Shield

Switch

Plate

3 2 1

Blue

Switch

Plate

Power

Cord

Red

Screw

Figure 19 - Installing Switch Plate to Valve Cover Shield

 

Wire

Valve Cover

Harness

Shield

Box Cover

 

Figure 18 - Installing Blower Bracket Assembly

12

107030

Image 12
Contents Shown with Optional Cabinet Mantel/Hearth Base Accessory What to do if YOU Smell GASSafety Information Compact Classic Hearth FireplaceProduct Features UnpackingLocal Codes Product IdentificationAssembly Installing LogAssembling Fireplace Assembling HoodAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installation ItemsCheck GAS Type Locating FireplaceBUILT-IN Fireplace Installation Locate fireplace where moving vehicle will not hit itMantel Clearances for Built-In Installation Optional MantelRaise the mantel to an accept Able heightInstalling Blower Accessory GA3450T Removing Upper Louver AssemblyInstalling Blower Assembly Assembling Brass Trim Brass trim shipped with mantelInstall the switch plate on the valve For Built-In Installation Extension CordConnecting to GAS Supply Attaching Wood Base to Solid FloorThread inlet connection and the flexible gas line provided Connecting Equipment Shutoff Valve to Heater Control Installation Items NeededValve should be accessible Pressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Inspecting Burner Cleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleBurner Flame Pattern CabinetTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Top Gas leak. See Warning statement atSpecifications Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown VMH26TPBParts List KEY Description QTYAccessories 107030 Warranty Information