Desa VMH26TPB 14 Specifications, Replacement Parts, Service Hints, Technical Service

Page 23

OWNER’S MANUAL

SPECIFICATIONS

Btu (Variable)

14,000/26,000

Type Gas

Propane/LP Only

Ignition

Piezo

Pressure Regulator Setting

8" W.C.

Inlet Gas Pressure (in. of water) *

 

Maximum

14"

Minimum

11"

Dimensions, Inches (H x W x D)

 

Fireplace (including hood and screws)

25 7/8 x 26 13/16 x 9 3/8

Carton

32 5/8 x 27 3/16 x 11 5/8

Weight, pounds

 

Fireplace

44 1/2 lbs.

Shipping

48 lbs.

* For purposes of input adjustment

 

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA International’s Technical Service Department at 1-866-672-6040 for referral information.

When calling DESA International, have ready

your name

your address

• model and serial numbers of your fireplace

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burner will have delayed ignition

fireplace will not produce specified heat

propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local propane/LP gas supplier.

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-866-672-6040.

You can also visit DESA International’s technical services web site at

www.desatech.com.

• how fireplace was malfunctioning

type of gas used (propane/LP or natural

 

gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA International at 1-866-672-6040 for referral information.

When calling DESA International, have ready

model number of your fireplace

the replacement part number

107030

23

Image 23
Contents What to do if YOU Smell GAS Shown with Optional Cabinet Mantel/Hearth Base AccessoryCompact Classic Hearth Fireplace Safety InformationProduct Identification Product FeaturesUnpacking Local CodesAssembling Hood AssemblyInstalling Log Assembling FireplaceConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Locating Fireplace InstallationInstallation Items Check GAS TypeLocate fireplace where moving vehicle will not hit it BUILT-IN Fireplace InstallationAble height Mantel Clearances for Built-In InstallationOptional Mantel Raise the mantel to an acceptAssembling Brass Trim Brass trim shipped with mantel Installing Blower Accessory GA3450TRemoving Upper Louver Assembly Installing Blower AssemblyInstall the switch plate on the valve Extension Cord For Built-In InstallationThread inlet connection and the flexible gas line provided Connecting to GAS SupplyAttaching Wood Base to Solid Floor Valve should be accessible Connecting Equipment Shutoff Valve to Heater ControlInstallation Items Needed Checking GAS Connections Pressure Testing Fireplace Gas ConnectionsPressure Testing Gas Supply Piping System Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Inspecting Burner Cabinet Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Burner Flame PatternObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at TopTechnical Service SpecificationsReplacement Parts Service HintsVMH26TPB Illustrated Parts BreakdownKEY Description QTY Parts ListAccessories 107030 Warranty Information