Desa VSGF36NR, VSGF36PR installation manual Installation Items Needed, Natural Gas, Propane/LP

Page 14

INSTALLATION

Continued

WARNING: Never connect natural gas fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

external regulator for propane/LP unit only (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap (optional)

tee joint

pipe wrench

approved flexible gas line with gas connector (if allowed by local codes) (not provided)

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 31.

For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pres- sure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 13. Pointing the vent down protects it from freezing rain or sleet.

Propane/LP

Supply Tank

External

Regulator

Vent

Pointing

Down

Figure 13 - External Regulator With Vent Pointing Down

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to fireplace. If pipe is too small, undue loss of volume will occur.

Installation must include an equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 14).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Check your building codes for any special re- quirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves. Never use sealant on flare threads.

CSA Design-Certified

Equipment Shutoff Valve

With 1/8" NPT Tap*

 

Natural Gas

 

From Gas Meter

 

(5" W.C.** to 10.5"

 

W.C. Pressure)

 

Propane/LP

 

From External

 

Regulator

 

(11" W.C.** to 14"

3" Minimum

W.C. Pressure)

 

 

Cap Pipe

Tee

 

Nipple

Joint

Sediment Trap

Figure 14 - Gas Connection

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 31.

** Minimum inlet pressure for purpose of input adjustment.

14

www.desatech.com

113192-01D

Image 14
Contents What to do if YOU Smell GAS Table of Contents Safety Information Local Codes Unpacking Product FeaturesProduct Identification Planning Product SpecificationsLocating Firebox Unusually Tight Construction AIR for Combustion VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building InstallationVentilation AIR Ventilation Air From OutdoorsInstallation Clearances Minimum Wall and Ceiling Clearances see FigureBUILT-IN Firebox Installation Mantel Clearances for Built-In InstallationRough Opening Dimensions for Built-in Installation Installing Firebox Using Optional Accessory Mantels Installing GAS Piping to Fireplace LocationPropane/LP Installation Items NeededNatural Gas Connecting Fireplace to GAS Supply Removing Log Base Assembly From FireplaceTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Groove HARD-WIRING Firebox Installing Fireplace Hood and ScreenLighting Instructions Thermostat Models For Your Safety Read Before LightingOperating Fireplace To Turn OFF GAS To Appliance Manual Lighting ProcedureRemote Control Models For Your Safety Read Before Lighting Thermostat Control OperationSet flame adjustment knob to any level between HI and LO ON/OFF Series Model Ghrcb Blower OperationOptional HAND-HELD Remote Operation Shutting Off HeaterThermostat Series Model Ghrctb Manual ModeAuto Shutoff Feature TurnsPilot Flame Pattern Key Pad Lock FeatureInspecting Burners Main BurnerCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleTechnical Service Wiring Diagram Replacement PartsSpecifications Service HintsTroubleshooting Observed Problem Possible Cause RemedyDiagram, See Cleaning and Mainte Shut off gas supply Do not try to light any appliance Accessories Illustrated Parts Breakdown Models VSGF36PT, VSGF36NTParts List Models VSGF36PR, VSGF36NR KEY Part Number VSGF36PR VSGF36NR Description QTY Models VSGF36PT, VSGF36NT, VSGF36PR and VSGF36NR KEY Part Number Description QTY 113192-01D 113192-01D Limited Warranty VENT-FREE GAS Fireplace System Warranty InformationKeep this Warranty

VSGF36NR, VSGF36PR specifications

The Desa VSGF36NR and VSGF36PR are innovative electric fireplaces designed to create a cozy atmosphere while ensuring modern efficiency. These models stand out in the electric fireplace market due to their blend of aesthetic appeal and advanced technology.

One of the key features of the VSGF36NR and VSGF36PR is their realistic flame technology, which provides a lifelike fire experience. The LED flame effect is adjustable, allowing users to customize the ambiance according to their preferences. This feature, combined with a log set that mimics real wood, offers an inviting glow that transforms any space.

Energy efficiency is another significant characteristic of these models. Both fireplaces use energy-efficient LED lights, resulting in lower energy consumption compared to traditional heating methods. Furthermore, they have adjustable heat settings, enabling users to control the amount of warmth emitted, which ultimately helps in managing energy expenditure and ensuring comfort.

The VSGF36NR is designed for natural venting, making it an ideal option for homes that require the integration of a venting system. On the other hand, the VSGF36PR model features a power vent option, providing versatility for installation in various spaces, including basements or rooms without existing venting. This flexibility facilitates installation in a range of environments, creating easy access to the warmth and charm of a fireplace.

Safety is a top priority with these models. They come equipped with an automatic shut-off feature, which activates if the unit overheats, ensuring peace of mind for users. The cool-to-the-touch exterior design further enhances safety, making these electric fireplaces suitable for homes with children and pets.

Both the VSGF36NR and VSGF36PR have a sleek, modern design, allowing them to fit seamlessly into any decor style, from contemporary to traditional. Their compact size means they can easily be integrated into living rooms, dining areas, or even bedrooms, making them a versatile addition.

Overall, the Desa VSGF36NR and VSGF36PR electric fireplaces are exemplary models combining aesthetics, advanced technology, and safety. They offer a practical solution for those looking to enjoy the warmth and comfort of a fireplace without the hassle of traditional wood-burning options. With their innovative features and thoughtful design, they are an excellent choice for enhancing any home.