Desa VSGF36NR, VSGF36PR To Turn OFF GAS To Appliance, Thermostat Control Operation

Page 20

OPERATING FIREPLACE

Continued

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This fireplace has a safety inter- lock system. Wait one (1) minute for system to reset before lighting pilot again.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

8.Turn control knob counterclockwise to desired heating level. The burners should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Ignitor Electrode

Pilot Burner

Figure 27 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

Turn control knob clockwise to the OFF position.

Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise to the PILOT position.

THERMOSTAT CONTROL

OPERATION

You can set the thermostat control knob to any comfort level between HI and LO. The thermo- stat will gradually modulate the heat output and flame height from higher to lower settings or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

Note: Selecting the HI setting will cause the burner to remain on without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, page 19.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instructions, column 1.

REMOTE CONTROL MODELS

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighborʼs phone. Follow the gas supplierʼs instructions.

If you cannot reach your gas supplier, call the fire department.

20

www.desatech.com

113192-01D

Image 20
Contents What to do if YOU Smell GAS Table of Contents Safety Information Local Codes Unpacking Product FeaturesProduct Identification Planning Product SpecificationsLocating Firebox AIR for Combustion Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceInstallation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsInstallation Clearances Minimum Wall and Ceiling Clearances see FigureBUILT-IN Firebox Installation Mantel Clearances for Built-In InstallationRough Opening Dimensions for Built-in Installation Installing Firebox Using Optional Accessory Mantels Installing GAS Piping to Fireplace LocationPropane/LP Installation Items NeededNatural Gas Connecting Fireplace to GAS Supply Removing Log Base Assembly From FireplaceTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Groove HARD-WIRING Firebox Installing Fireplace Hood and ScreenLighting Instructions Thermostat Models For Your Safety Read Before LightingOperating Fireplace Manual Lighting Procedure Remote Control Models For Your Safety Read Before LightingTo Turn OFF GAS To Appliance Thermostat Control OperationSet flame adjustment knob to any level between HI and LO Blower Operation Optional HAND-HELD Remote OperationON/OFF Series Model Ghrcb Shutting Off HeaterManual Mode Auto Shutoff FeatureThermostat Series Model Ghrctb TurnsKey Pad Lock Feature Inspecting BurnersPilot Flame Pattern Main BurnerCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleWiring Diagram Replacement Parts SpecificationsTechnical Service Service HintsTroubleshooting Observed Problem Possible Cause RemedyDiagram, See Cleaning and Mainte Shut off gas supply Do not try to light any appliance Accessories Illustrated Parts Breakdown Models VSGF36PT, VSGF36NTParts List Models VSGF36PR, VSGF36NR KEY Part Number VSGF36PR VSGF36NR Description QTY Models VSGF36PT, VSGF36NT, VSGF36PR and VSGF36NR KEY Part Number Description QTY 113192-01D 113192-01D Limited Warranty VENT-FREE GAS Fireplace System Warranty InformationKeep this Warranty

VSGF36NR, VSGF36PR specifications

The Desa VSGF36NR and VSGF36PR are innovative electric fireplaces designed to create a cozy atmosphere while ensuring modern efficiency. These models stand out in the electric fireplace market due to their blend of aesthetic appeal and advanced technology.

One of the key features of the VSGF36NR and VSGF36PR is their realistic flame technology, which provides a lifelike fire experience. The LED flame effect is adjustable, allowing users to customize the ambiance according to their preferences. This feature, combined with a log set that mimics real wood, offers an inviting glow that transforms any space.

Energy efficiency is another significant characteristic of these models. Both fireplaces use energy-efficient LED lights, resulting in lower energy consumption compared to traditional heating methods. Furthermore, they have adjustable heat settings, enabling users to control the amount of warmth emitted, which ultimately helps in managing energy expenditure and ensuring comfort.

The VSGF36NR is designed for natural venting, making it an ideal option for homes that require the integration of a venting system. On the other hand, the VSGF36PR model features a power vent option, providing versatility for installation in various spaces, including basements or rooms without existing venting. This flexibility facilitates installation in a range of environments, creating easy access to the warmth and charm of a fireplace.

Safety is a top priority with these models. They come equipped with an automatic shut-off feature, which activates if the unit overheats, ensuring peace of mind for users. The cool-to-the-touch exterior design further enhances safety, making these electric fireplaces suitable for homes with children and pets.

Both the VSGF36NR and VSGF36PR have a sleek, modern design, allowing them to fit seamlessly into any decor style, from contemporary to traditional. Their compact size means they can easily be integrated into living rooms, dining areas, or even bedrooms, making them a versatile addition.

Overall, the Desa VSGF36NR and VSGF36PR electric fireplaces are exemplary models combining aesthetics, advanced technology, and safety. They offer a practical solution for those looking to enjoy the warmth and comfort of a fireplace without the hassle of traditional wood-burning options. With their innovative features and thoughtful design, they are an excellent choice for enhancing any home.