Desa VMH26TPC, VMH26TNC Checking GAS Connections, Pressure Testing Gas Supply Piping System

Page 18

INSTALLATION

Continued

To Fireplace

Equipment Shutoff

Gas Regulator

Valve Provided by

 

 

Installer

Flexible Gas Line

 

from Fireplace Gas

 

Regulator Provided

PROPANE/LP

with Fireplace

To External Regulator

 

 

NATURAL

 

To Gas Supply

Figure 25 - Attaching Flexible Gas Line

to Equipment Shutoff Valve

CHECKING GAS CONNECTIONS

WARNING: Test all gas pip- ing and connections, internal and external to unit, for leaks after installing or servicing. Cor- rect all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak de- tection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

CAUTION: Make sure external regulator has been installed be- tweenpropane/LPsupplyandfire- place. See guidelines under Con- necting to Gas Supply, page 16.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping. Pres- sures in excess of 1/2 psig will damage fire- place regulator.

2.Cap off open end of gas pipe where equip- ment shutoff valve was connected.

3.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve lo-

cated on or near gas meter for natural gas, or using compressed air.

4.Check all joints of gas supply piping system. Apply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 26).

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using compressed air.

3.Check all joints from gas meter for natural or propane/LP supply to equipment shutoff valve (see Figures 27 and 28, page 19). Apply a non- corrosive leak detection fluid to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Pressure Testing Fireplace Gas Connections

1.Open equipment shutoff valve (see Figure 26).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP sup- ply tank valve.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from equipment shutoff valve to thermostat gas valve (see Figures 27 and 28, page 19). Apply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light fireplace (see Operating Fireplace, pages 19 and 21). Check all other internal joints for leaks.

7.Turn off fireplace (see To Turn Off Gas to Appliance, page 20).

8.Replace front panel.

Equipment Open

Shutoff

Valve

CPOlosed

Figure 26 - Equipment Shutoff Valve

18

www.desatech.com

113111-01B

Image 18
Contents Shown with Optional Cabinet Mantel/Hearth Base Accessory What to do if YOU Smell GASTable of Contents Safety Information Local Codes Product IdentificationProduct Features AssemblyUnpacking Assembling Hood AIR for Combustion VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining FRESH-AIR Flow for Fireplace Location Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installation ItemsCheck GAS Type BUILT-IN Fireplace Installation Locating FireplaceRough Opening for Installing Wall Optional Mantel Installation Mantel Clearances for Built-In InstallationAssembling Perimeter Trim Trim Shipped with Mantel Installing Blower Accessory GA3450TRemoving Upper Louver Assembly Removing Valve Cover ShieldInstalling Blower Assembly Removing Valve Cover ShieldInstalling Switch Plate to Valve Cover Shield For Built-In InstallationConnecting to GAS Supply Attaching Wood Base to Solid FloorExtension Cord Connecting Equipment Shutoff Valve to Heater Control Installation Items NeededPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Thermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off FireplaceBurner Flame Pattern Inspecting BurnerOperating Blower Pilot Flame PatternCabinet Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole Air PassagewaysTroubleshooting Observed Problem Possible Cause RemedySee Cleaning and Mainte Residues from manufacturing Gas leak. See Warning Statement aboveTechnical Service SpecificationsService Hints Replacement PartsIllustrated Parts Breakdown Parts List Accessories Cabinet Mantel and Full Hearth Base Cleaning KIT GCKCorner Mantel with Full Hearth Base Information VideoWarranty Information Keep this WarrantyLimited Warranty VENT-FREE Compact Classic Hearth Fireplace