FIREPLACE MANUFACTURERS INC.
UNVENTED PROPANE/LP GAS LOG HEATER
TROUBLESHOOTING
Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.
Note: All troubleshooting items are listed in order of operation.
 WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater.
 CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||
When ignitor button is pressed, there is no  | 1.  | Ignitor electrode not connected to igni-  | 1.  | Reconnect ignitor cable  | 
spark at ODS/pilot  | 
  | tor cable  | 
  | 
  | 
  | 2.  | Ignitor cable pinched or wet  | 2.  | Free ignitor cable if pinched by any  | 
  | 
  | 
  | 
  | metal or tubing. Keep ignitor cable dry  | 
  | 3.  | Piezo ignitor nut is loose  | 3.  | Tighten nut holding piezo ignitor to base  | 
  | 
  | 
  | 
  | panel of log set. Nut is located behind  | 
  | 
  | 
  | 
  | base panel  | 
  | 4.  | Broken ignitor cable  | 4.  | Replace ignitor cable  | 
  | 5.  | Bad piezo ignitor  | 5.  | Replace piezo ignitor  | 
  | 6.  | Ignitor electrode positioned wrong  | 6.  | Replace ignitor  | 
  | 7.  | Ignitor electrode broken  | 7.  | Replace ignitor  | 
  | 
  | 
  | 
  | 
  | 
When ignitor button is pressed, there is  | 1.  | Gas supply turned off or equipment  | 1.  | Turn on gas supply or open equipment  | 
spark at ODS/pilot but no ignition  | 
  | shutoff valve closed  | 
  | shutoff valve  | 
  | 2.  | Control knob not in PILOT position  | 2.  | Turn control knob to PILOT position  | 
  | 3.  | Control knob not pressed in while in  | 3.  | Press in control knob while in PILOT  | 
  | 
  | PILOT position  | 
  | position  | 
  | 4.  | Air in gas lines when installed  | 4.  | Continue holding down control knob.  | 
  | 
  | 
  | 
  | Repeat igniting operation until air is re-  | 
  | 
  | 
  | 
  | moved  | 
  | 5.  | Depleted gas supply  | 5.  | Contact local propane/LP gas company  | 
  | 6.  | ODS/pilot is clogged  | 6.  | Clean ODS/pilot (see Cleaning and  | 
  | 
  | 
  | 
  | Maintenance, page 17) or replace ODS/  | 
  | 
  | 
  | 
  | pilot assembly  | 
  | 7.  | Gas control setting is not correct  | 7.  | Replace gas control  | 
  | 
  | 
  | 
  | 
  | 
ODS/pilot lights but flame goes out when  | 1.  | Control knob not fully pressed in  | 1.  | Press in control knob fully  | 
control knob is released  | 2.  | Control knob not pressed in long enough  | 2.  | After ODS/pilot lights, keep control  | 
  | 
  | 
  | 
  | knob pressed in 30 seconds  | 
  | 3.  | Equipment shutoff valve not fully open  | 3.  | Fully open equipment shutoff valve  | 
  | 4.  | Pilot flame not touching thermocouple,  | 4.  | A) Contact local propane/LP gas  | 
  | 
  | which allows thermocouple to cool,  | 
  | company  | 
  | 
  | causing pilot flame to go out. This prob-  | 
  | B) Clean ODS/pilot (see Cleaning and  | 
  | 
  | lem could be caused by one or both of  | 
  | Maintenance, page 17) or replace ODS/  | 
  | 
  | the following:  | 
  | pilot assembly  | 
  | 
  | A) Low gas pressure  | 
  | 
  | 
  | 
  | B) Dirty or partially clogged ODS/pilot  | 
  | 
  | 
  | 5.  | Thermocouple connection loose at con-  | 5.  | Hand tighten until snug, then tighten 1/4  | 
  | 
  | trol valve  | 
  | turn more  | 
  | 6.  | Thermocouple damaged  | 6.  | Replace thermocouple  | 
  | 7.  | Gas control damaged  | 7.  | Replace gas control  | 
www.desatech.com