FMI VFP30R, VFP24R, VFP18R Troubleshooting, Observed Problem Possible Cause Remedy

Page 18

FIREPLACE MANUFACTURERS INC.

UNVENTED PROPANE/LP GAS LOG HEATER

TROUBLESHOOTING

Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no

1.

Ignitor electrode not connected to igni-

1.

Reconnect ignitor cable

spark at ODS/pilot

 

tor cable

 

 

 

2.

Ignitor cable pinched or wet

2.

Free ignitor cable if pinched by any

 

 

 

 

metal or tubing. Keep ignitor cable dry

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding piezo ignitor to base

 

 

 

 

panel of log set. Nut is located behind

 

 

 

 

base panel

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

6.

Ignitor electrode positioned wrong

6.

Replace ignitor

 

7.

Ignitor electrode broken

7.

Replace ignitor

 

 

 

 

 

When ignitor button is pressed, there is

1.

Gas supply turned off or equipment

1.

Turn on gas supply or open equipment

spark at ODS/pilot but no ignition

 

shutoff valve closed

 

shutoff valve

 

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position

 

3.

Control knob not pressed in while in

3.

Press in control knob while in PILOT

 

 

PILOT position

 

position

 

4.

Air in gas lines when installed

4.

Continue holding down control knob.

 

 

 

 

Repeat igniting operation until air is re-

 

 

 

 

moved

 

5.

Depleted gas supply

5.

Contact local propane/LP gas company

 

6.

ODS/pilot is clogged

6.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 17) or replace ODS/

 

 

 

 

pilot assembly

 

7.

Gas control setting is not correct

7.

Replace gas control

 

 

 

 

 

ODS/pilot lights but flame goes out when

1.

Control knob not fully pressed in

1.

Press in control knob fully

control knob is released

2.

Control knob not pressed in long enough

2.

After ODS/pilot lights, keep control

 

 

 

 

knob pressed in 30 seconds

 

3.

Equipment shutoff valve not fully open

3.

Fully open equipment shutoff valve

 

4.

Pilot flame not touching thermocouple,

4.

A) Contact local propane/LP gas

 

 

which allows thermocouple to cool,

 

company

 

 

causing pilot flame to go out. This prob-

 

B) Clean ODS/pilot (see Cleaning and

 

 

lem could be caused by one or both of

 

Maintenance, page 17) or replace ODS/

 

 

the following:

 

pilot assembly

 

 

A) Low gas pressure

 

 

 

 

B) Dirty or partially clogged ODS/pilot

 

 

 

5.

Thermocouple connection loose at con-

5.

Hand tighten until snug, then tighten 1/4

 

 

trol valve

 

turn more

 

6.

Thermocouple damaged

6.

Replace thermocouple

 

7.

Gas control damaged

7.

Replace gas control

www.desatech.com

18

105073

Image 18
Contents Unvented VENT-FREE PROPANE/LP GAS LOG Heater What to do if YOU Smell GASSafety Information Product Features Unpacking Local CodesProduct Identification Providing Adequate Ventilation Optional Remote Control AccessoriesAIR for Combustion and Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Check GAS TypeIf Using Mantel Minimum Noncombustible Material ClearancesFloor Clearances Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Connecting to GAS Supply Minimum inlet pressure for purpose of input adjustmentPressure Testing Heater Gas Connections Pressure Testing gas Supply Piping systemChecking GAS Connections Installing Logs Installing Front Log #1For Your Safety Read Before Lighting Operating HeaterLighting Instructions Manual Lighting Procedure To Turn OFF GAS to ApplianceOptional Remote Operation Inspecting Burners Pilot Flame PatternFront Burner Flame Pattern Cleaning and Maintenance Cleaning Burners Injector Holder and Pilot AIR Inlet HoleLogs Troubleshooting Observed Problem Possible Cause RemedySee Wiring Diagram, Gas leak. See Warning statement Replacement Parts SpecificationsWiring Diagram Service HintsIllustrated Parts Breakdown VFP18R VFP24R VFP30RParts List KEY Part Numbers VFP18R VFP24R VFP30R Description QTYAccessories 105073 Warranty Information