FMI VFP18R, VFP30R, VFP24R Minimum Noncombustible Material Clearances, If Using Mantel

Page 8

FIREPLACE MANUFACTURERS INC.

UNVENTED PROPANE/LP GAS LOG HEATER

INSTALLATION

Continued

NOTICE: Manual control heaters may be used as a vented prod- uct. If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fireplace open- ing is not needed. Go to Install- ing Damper Clamp Accessory for Vented Operation, page 10.

If Using Mantel

You must have noncombustible material(s) above the fireplace opening. Noncombus- tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible mate- rial must extend at least 8 inches up. If noncombustible material is less than 12", you must install the fireplace hood acces- sory. Even if noncombustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and Figures 6 and 7, page 9 for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. See Install- ing Damper Clamp Accessory for Vented Operation, page 10.

Minimum Noncombustible Material Clearances

If Not Using Mantel

Note: If using a mantel, see If Using Man- tel. If not using a mantel, follow the infor- mation below.

You must have noncombustible material(s) above the fireplace opening. Noncombus- tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible material must extend at least 8" up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory. See Figure 5 for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. See Install- ing Damper Clamp Accessory for Vented Operation, page 10.

Noncombustible

Requirements for

Material Distance (A)

Safe Installation

 

 

12" or more

Noncombustible material OK.

Between 8" and 12"

Install fireplace hood accessory (HDABK or

 

HDABR, see Accessories, page 24).

 

18" model: Noncombustible material OK.

Less than 8"

Noncombustible material must be extended to at

 

least 8". See Between 8" and 12", above. If you

 

cannot extend material, you must operate heater

 

with flue damper open.

 

 

Heat Resistant

Material

(A)

Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

8

105073

Image 8
Contents Unvented VENT-FREE PROPANE/LP GAS LOG Heater What to do if YOU Smell GASSafety Information Product Identification Product FeaturesUnpacking Local Codes Optional Remote Control Accessories AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Check GAS TypeIf Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Connecting to GAS Supply Minimum inlet pressure for purpose of input adjustmentChecking GAS Connections Pressure Testing Heater Gas ConnectionsPressure Testing gas Supply Piping system Installing Logs Installing Front Log #1Lighting Instructions For Your Safety Read Before LightingOperating Heater Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS to Appliance Front Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Logs Cleaning and MaintenanceCleaning Burners Injector Holder and Pilot AIR Inlet Hole Troubleshooting Observed Problem Possible Cause RemedySee Wiring Diagram, Gas leak. See Warning statement Specifications Wiring DiagramReplacement Parts Service HintsIllustrated Parts Breakdown VFP18R VFP24R VFP30RParts List KEY Part Numbers VFP18R VFP24R VFP30R Description QTYAccessories 105073 Warranty Information