Fig. 31

7DVCS must be used to support offsets. (Fig. 36)This application will require that you rst determine the roof pitch and use the appropriate starter kit. (See Venting Components List)

The minimum height of the vent above the highest point of penetration through the roof is 2'. See Fig. 38.

VERTICAL RESTRICTOR PLATE

(DBT33 ONLY)

When installing the DBT33 with a Vertical Through-The-Roof congured ue system the restrictor plate, (#10002495) sup- plied with the appliance MUST BE FITTED TO THE APPLIANCE at installation.

Fitting The Restrictor Plate

1.Remove the window glass/frame assembly.

2.Locate the rebox bafe assembly in the top rear area of the rebox, Fig. 32.

3.Remove the four (4) nuts along the front edge, and the three (3) screws along the rear edge of the bafe assembly. Remove the bafe assembly from the rebox.

Fig. 32

4.Remove the two (2) screws from the top face of the bafe assembly, Fig. 32. Place the restrictor plate as shown in Fig. 34 and secure by retting the screws.

Fig. 33

Fig. 34

5.Ret the bafe assembly to the rebox, replacing the three

(3) screws and four (4) nuts.

6.Ret window glass/frame as per the appropriate sections of this manual.

DBT33/DBT36/DBT39

-16-

10002789/0

Image 16
Contents DBT33 DBT36 DBT39 Table of Contents Installation & O Perating Instructions Locating Your FireplaceAppliance Dimensions Appliance DimensionsFraming Dimensions Clearance to Combustibles MantelsHearth Framing and FinishingFinal Finishing GAS SpecificationsGAS Inlet & Manifold Pressures GAS Line Installation Remote ON/OFF SwitchInstallation Alternative Switch LocationFrom LP to Natural GAS or Converting the ApplianceNatural GAS to LP General Venting Information Termination Location Location of Vent TerminationDBT33/DBT36/DBT39 HOW to USE the Vent Graph General Information on Assembling DV ComponentsCrimped End Pipes Twist Lock PipesVertical Sidewall Applications Vertical Sidewall Installations Install restop assembly FigBelow Grade Installations Apply high temperature sealant to 4 100 mm and 7Vertical THROUGH-THE-ROOF Applications This Gas Fireplace has been approved forVertical Restrictor Plate Fitting The Restrictor PlateVertical THROUGH-THE-ROOF Installation Place replace into position7DVP1834 Crimped END Venting Components7DVP3466 Twist Lock Venting Components General Maintenance Glass CleaningGeneral Operating Instructions Glass Information Louvre RemovalInstallation of Logs Lava Rock LocationFlame Characteristics Flame & Temperature AdjustmentRN/RP & EN/EP Models Turn on all electrical power to the replace Settle on the oorTrouble Shooting the GAS Control System Pilot. If no spark to pilot, and electrode wire is properly Defective ignitor Push ButtonConnected, replace ignitor Thermopile and thermocoupleReplacement Parts List Description Parts Pictorial Optional Accessories Available EB-1 Electrical BOX FK24 Fan AssemblyMaintenance FAN KitsWiring Instructions FK12Method a Method BInstallation, refer Fig Replace the logs and frame/glass assemblyCeramic Refractory Kits Front Window ScreenDecorative BAY Windows Remote ControlsModel Function/s Controlled Page Limited Warranty & Extended Life Time Protection

DBT39, DBT36, DBT33 specifications

Vermont Castings has long been a name synonymous with quality and craftsmanship in the realm of cast iron stoves and fireplaces. Among their range, the DBT33, DBT36, and DBT39 models stand out due to their unique features and advanced technology, designed to meet the varying needs of homeowners looking for an efficient heating solution.

The DBT33 model offers a compact yet powerful design, making it ideal for tighter spaces while still delivering robust heating capabilities. With a BTU output of up to 33,000, it can effectively warm a medium-sized room. One of its main features is the advanced air wash system that helps keep the glass clean, providing you with an unobstructed view of the mesmerizing flames. It’s equipped with Vermont Castings' patented Intelli-Fire technology, which provides a user-friendly operation, ensuring optimal efficiency and performance.

Moving up in size and features, the DBT36 is built for slightly larger spaces but retains the same elegant design and efficiency. It boasts a BTU output of up to 36,000, making it suitable for larger rooms or even open-concept spaces. One standout characteristic is its built-in thermostat that automatically adjusts the burner to maintain a consistent temperature. This model also incorporates a secondary combustion system, which boosts efficiency and reduces emissions, making it an eco-friendlier choice.

Finally, the DBT39 takes it a step further with a powerful output of up to 39,000 BTUs, perfect for heating expansive areas. It features a sleek design that fits seamlessly into various home aesthetics, whether modern or traditional. Notably, the DBT39 is designed with multiple burning modes, allowing users to choose between high heat for quick warmth or lower settings for prolonged, even heat. Its innovative heat exchanger design improves heat transfer, ensuring maximum efficiency while lowering fuel consumption.

All three models utilize Vermont Castings' renowned cast iron construction, which not only enhances durability but also improves heat retention. They also come equipped with safety features such as a built-in heat shield to prevent overheating, ensuring peace of mind for users.

In summary, the Vermont Castings DBT series – DBT33, DBT36, and DBT39 – offers a range of options tailored to various heating needs. Their combination of stylish design, robust performance, and advanced technologies sets them apart in the market, appealing to homeowners who value both functionality and aesthetics in their heating solutions. With Vermont Castings, warmth and elegance go hand in hand.