OPTIONAL ACCESSORIES AVAILABLE

EB-1 ELECTRICAL BOX

The EB-1 Electrical junction box when tted and correctly wired gives an easy and convenient power outlet for the optioal fan kit.

If the EB-1 electrical junction box is being tted the replace must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electric Code.

For U.S.A. installations follow the local codes and the national electrical code ANSI/NFPA No 70.

It is strongly recommended that the wiring of the EB-1 Electrical Junction Box be carried out be a licensed electrician.

Ensure that the power to the supply line has been disconnected before commencing this pro- cedure.

To install and connect the EB-1 box to the house electrical supply follow the steps below.

1.Disconnect the power to the electrical supply line.

2.Remove the cover plate over the EB-1 knock-out the side of the appliance, retain the screw that held the plate.

3.Remove the front cover of the EB-1 box.

4.Remove the plug socket assembly from the EB-1 box.

5.Feed the electrical supply line in through the EB-1 open- ing in the side of the appliance and then through the back of the EB-1 assembly, Fig ???.

6.Connect the ground wire of the supply line to the green screw of the socket assembly.

7.Connect the white wire of the power line to the chrome screw of the socket assembly.

8.Connect the black wire of the power supply line to the brass screw (polarized) of the socket assembly.

9.Ret the socket assembly back into the electrical box and replace the front cover plate. Secure the cable with the clamp on the outside of the EB-1 base plate and ret the EB-1 assembly to the appliance with the screw removed in step 1.

FAN KITS

FK24 Fan Assembly

This auxiliary fan system increases the efciency of the circu- lation of the heating air.

The FK24 fan kit allows variable speed control of the circula- tion fan and also incorporates a heat sensor in the circuit. Specications

115 Volt / 60 Hz / 56 Watts

Maintenance

The fan itself does not require regular maintenance, however periodic cleaning of the fan and the surrounding area is required.

Check the area under the control door (lower louvre assembly) and in front of the fan and wipe or vacuum this area at least once a month during the operating season.

Installation

The fan assembly and other components are supplied fully wired eliminating the need for a licensed electrician to carry out the installation

If hard wiring the fan using Method B (following) we strongly recommend the use of a licensed electrician.

1Open the lower Louvre assembly. Maneuver the fan & bracket assembly around the gas valve and lines to locate the unit onto the screw studs on the back of the replace

2Install the thermal sensor under the bottom of the rebox, locating it over the two 10 mm studs and secure it with nuts.

10002789/0

-29-

DBT33/DBT36/DBT39

Image 29
Contents DBT33 DBT36 DBT39 Table of Contents Locating Your Fireplace Installation & O Perating InstructionsFraming Dimensions Appliance DimensionsAppliance Dimensions Mantels Clearance to CombustiblesHearth Framing and FinishingGAS Inlet & Manifold Pressures GAS SpecificationsFinal Finishing Remote ON/OFF Switch GAS Line InstallationInstallation Alternative Switch LocationNatural GAS to LP Converting the ApplianceFrom LP to Natural GAS or Location of Vent Termination General Venting Information Termination LocationDBT33/DBT36/DBT39 General Information on Assembling DV Components HOW to USE the Vent GraphCrimped End Pipes Twist Lock PipesVertical Sidewall Applications Install restop assembly Fig Vertical Sidewall InstallationsApply high temperature sealant to 4 100 mm and 7 Below Grade InstallationsThis Gas Fireplace has been approved for Vertical THROUGH-THE-ROOF ApplicationsFitting The Restrictor Plate Vertical Restrictor PlatePlace replace into position Vertical THROUGH-THE-ROOF Installation7DVP3466 Crimped END Venting Components7DVP1834 Twist Lock Venting Components Glass Cleaning General MaintenanceGeneral Operating Instructions Glass Information Louvre RemovalLocation Installation of Logs Lava RockRN/RP & EN/EP Models Flame & Temperature AdjustmentFlame Characteristics Settle on the oor Turn on all electrical power to the replaceTrouble Shooting the GAS Control System Defective ignitor Push Button Pilot. If no spark to pilot, and electrode wire is properlyConnected, replace ignitor Thermopile and thermocoupleReplacement Parts List Description Parts Pictorial FK24 Fan Assembly Optional Accessories Available EB-1 Electrical BOXMaintenance FAN KitsFK12 Wiring InstructionsMethod a Method BReplace the logs and frame/glass assembly Installation, refer FigCeramic Refractory Kits Front Window ScreenModel Function/s Controlled Remote ControlsDecorative BAY Windows Page Limited Warranty & Extended Life Time Protection

DBT39, DBT36, DBT33 specifications

Vermont Castings has long been a name synonymous with quality and craftsmanship in the realm of cast iron stoves and fireplaces. Among their range, the DBT33, DBT36, and DBT39 models stand out due to their unique features and advanced technology, designed to meet the varying needs of homeowners looking for an efficient heating solution.

The DBT33 model offers a compact yet powerful design, making it ideal for tighter spaces while still delivering robust heating capabilities. With a BTU output of up to 33,000, it can effectively warm a medium-sized room. One of its main features is the advanced air wash system that helps keep the glass clean, providing you with an unobstructed view of the mesmerizing flames. It’s equipped with Vermont Castings' patented Intelli-Fire technology, which provides a user-friendly operation, ensuring optimal efficiency and performance.

Moving up in size and features, the DBT36 is built for slightly larger spaces but retains the same elegant design and efficiency. It boasts a BTU output of up to 36,000, making it suitable for larger rooms or even open-concept spaces. One standout characteristic is its built-in thermostat that automatically adjusts the burner to maintain a consistent temperature. This model also incorporates a secondary combustion system, which boosts efficiency and reduces emissions, making it an eco-friendlier choice.

Finally, the DBT39 takes it a step further with a powerful output of up to 39,000 BTUs, perfect for heating expansive areas. It features a sleek design that fits seamlessly into various home aesthetics, whether modern or traditional. Notably, the DBT39 is designed with multiple burning modes, allowing users to choose between high heat for quick warmth or lower settings for prolonged, even heat. Its innovative heat exchanger design improves heat transfer, ensuring maximum efficiency while lowering fuel consumption.

All three models utilize Vermont Castings' renowned cast iron construction, which not only enhances durability but also improves heat retention. They also come equipped with safety features such as a built-in heat shield to prevent overheating, ensuring peace of mind for users.

In summary, the Vermont Castings DBT series – DBT33, DBT36, and DBT39 – offers a range of options tailored to various heating needs. Their combination of stylish design, robust performance, and advanced technologies sets them apart in the market, appealing to homeowners who value both functionality and aesthetics in their heating solutions. With Vermont Castings, warmth and elegance go hand in hand.