Vermont Casting DBT36, DBT39 Installation & O Perating Instructions, Locating Your Fireplace

Page 3

 

INSTALLATION & O

PERATING INSTRUCTIONS

 

This gas replace should be installed by a qualied installer

 

 

 

 

 

 

This appliance has been approved for

in accordance with local building codes and with current CAN

 

 

/CGA-B149 (. 1 or .2) Installation codes for Gas Burning

 

 

after-market mobile home installations

Fireplaces and Equipment.

 

 

 

 

 

 

 

 

FOR U.S.A Installations follow local codes and/or the current

 

 

 

 

 

 

IMPORTANT:

National Fuel Gas Code. ANSI Z223.1.

 

 

 

 

PLEASE REVIEW THE FOLLOWING CAREFULLY

FOR SAFE INSTALLATION AND OPERATION PLEASE

 

 

 

 

Remove any plastic from trim parts before turning the re-

NOTE THE FOLLOWING:

 

 

 

 

place ON.

 

1.

This replace gives off high temperatures and should be

 

 

 

 

 

It is normal for replaces fabricated of steel to give off

 

located out of high trafc areas and away from furniture

 

 

 

 

 

some expansion and/or contraction noises during the start

 

and draperies.

 

 

 

 

 

up or cool down cycle. Similar noises are found with your

2.

Children and adults should be alerted to the hazards of the

 

 

 

 

furnace heat exchanger or car engine.

 

high surface temperatures of this replace and should stay

 

 

 

 

 

It is not unusual for your gas replace to give off some

 

away to avoid burns or ignition of clothing.

 

 

 

 

 

odour the rst time it is burned. This is due to the curing

3.

Caution, due to high glass surface temperature children

 

 

 

 

of the paint and any undetected oil from the manufacturing

 

should be carefully supervised when they are in the same

 

 

 

 

 

process.

 

 

room as the replace.

 

 

 

 

 

 

Please ensure that your room is well ventilated - open all

4.

Under no circumstances should this replace be modied.

 

 

 

 

windows.

 

 

Parts removed for servicing should be replaced prior to

 

 

 

 

 

 

It is recommended that you burn your replace for a least

 

operating the replace again.

 

 

 

 

 

six (6) hours the rst time you use it. If the optional fan

5.

Installation and any repairs to this replace should be

 

 

 

 

kit has been installed, place the fan switch in the “OFF”

 

carried out by a qualied service person. A professional

 

 

 

 

 

position during this time.

 

 

service person should be contacted to inspect this replace

 

 

 

 

 

 

 

 

 

annually. Make it a practice to have all of your gas re-

 

 

 

 

 

 

 

LOCATING YOUR FIREPLACE

 

places checked annually. More frequent cleaning may

 

 

 

be required due to excess lint and dust from carpeting,

 

 

 

 

 

 

 

 

 

 

bedding material, etc.

 

 

 

 

6.

Control compartments, burners and air passages in this

 

 

 

 

 

replace should be kept clean and free of dust and lint.

 

 

 

 

 

Make sure that the gas valve and pilot light are turned off

 

 

 

 

 

before you attempt to clean this replace.

 

 

 

 

7.

The venting system (chimney) of this replace should be

 

 

 

 

 

checked at least once a year and if needed your venting

 

 

 

 

 

system should be cleaned.

 

 

 

 

8.

Keep the area around your replace clear of combustible

 

 

 

 

 

materials, gasoline and other ammable vapour and liq-

 

 

 

 

 

uids. This replace should not be used as a drying rack for

 

 

 

 

 

clothing, nor should Christmas stockings or decorations

 

 

 

 

 

be hung on or around the replace.

 

 

 

 

9.

Under no circumstances should any solid fuels (wood,

 

 

 

 

 

coal, paper or cardboard etc.) be used in this replace.

 

 

 

 

10.

The ow of combustion and ventilation air must not be

 

 

 

Fig. 1

 

obstructed in any way.

 

 

 

 

 

 

 

 

11.

When the replace is installed directly on carpeting, vinyl

 

 

A - Flat on the wall

B - Cross Corner

 

tile or any combustible material other than wood, the

 

 

C - * Island

D - ** Room Divider

 

replace must be installed on a metal or wood panel

 

 

E - ** Flat on wall (in corner)

F - Chase Installation

 

extending the full width and depth of the replace.

 

 

* Island (C) and Room Divider (D) installation is possible

12.

This replace must not be connected to a chimney ue

 

 

 

 

as long as the horizontal portion of the vent system (X)

 

serving a separate solid fuel burning replace.

 

 

 

 

 

does not exceed 20' (6.1 m). See details in the venting

13.

When the replace is not in use it is recommended that the

 

 

 

 

section of this manual.

 

 

gas control valve be left in the OFF position.

 

 

 

 

 

 

** When you install your replace in a Room divider (D)

 

 

 

 

 

 

 

 

or at on the wall in a corner (E), a minimum distance

 

 

 

 

of 6" (153 mm) clearance must be maintained from the

 

 

 

 

perpendicular wall and the front of the appliance. See

 

 

 

 

(Y) in Fig. 1.

 

 

 

 

 

 

 

10002789/0

-3-

DBT33/DBT36/DBT39

Image 3
Contents DBT33 DBT36 DBT39 Table of Contents Locating Your Fireplace Installation & O Perating InstructionsAppliance Dimensions Appliance DimensionsFraming Dimensions Framing and Finishing Clearance to CombustiblesMantels HearthGAS Specifications Final FinishingGAS Inlet & Manifold Pressures Alternative Switch Location GAS Line InstallationRemote ON/OFF Switch InstallationConverting the Appliance From LP to Natural GAS orNatural GAS to LP Location of Vent Termination General Venting Information Termination LocationDBT33/DBT36/DBT39 Twist Lock Pipes HOW to USE the Vent GraphGeneral Information on Assembling DV Components Crimped End PipesVertical Sidewall Applications Install restop assembly Fig Vertical Sidewall InstallationsApply high temperature sealant to 4 100 mm and 7 Below Grade InstallationsThis Gas Fireplace has been approved for Vertical THROUGH-THE-ROOF ApplicationsFitting The Restrictor Plate Vertical Restrictor PlatePlace replace into position Vertical THROUGH-THE-ROOF InstallationCrimped END Venting Components 7DVP18347DVP3466 Twist Lock Venting Components Louvre Removal General MaintenanceGlass Cleaning General Operating Instructions Glass InformationLocation Installation of Logs Lava RockFlame & Temperature Adjustment Flame CharacteristicsRN/RP & EN/EP Models Settle on the oor Turn on all electrical power to the replaceTrouble Shooting the GAS Control System Thermopile and thermocouple Pilot. If no spark to pilot, and electrode wire is properlyDefective ignitor Push Button Connected, replace ignitorReplacement Parts List Description Parts Pictorial FAN Kits Optional Accessories Available EB-1 Electrical BOXFK24 Fan Assembly MaintenanceMethod B Wiring InstructionsFK12 Method aFront Window Screen Installation, refer FigReplace the logs and frame/glass assembly Ceramic Refractory KitsRemote Controls Decorative BAY WindowsModel Function/s Controlled Page Limited Warranty & Extended Life Time Protection

DBT39, DBT36, DBT33 specifications

Vermont Castings has long been a name synonymous with quality and craftsmanship in the realm of cast iron stoves and fireplaces. Among their range, the DBT33, DBT36, and DBT39 models stand out due to their unique features and advanced technology, designed to meet the varying needs of homeowners looking for an efficient heating solution.

The DBT33 model offers a compact yet powerful design, making it ideal for tighter spaces while still delivering robust heating capabilities. With a BTU output of up to 33,000, it can effectively warm a medium-sized room. One of its main features is the advanced air wash system that helps keep the glass clean, providing you with an unobstructed view of the mesmerizing flames. It’s equipped with Vermont Castings' patented Intelli-Fire technology, which provides a user-friendly operation, ensuring optimal efficiency and performance.

Moving up in size and features, the DBT36 is built for slightly larger spaces but retains the same elegant design and efficiency. It boasts a BTU output of up to 36,000, making it suitable for larger rooms or even open-concept spaces. One standout characteristic is its built-in thermostat that automatically adjusts the burner to maintain a consistent temperature. This model also incorporates a secondary combustion system, which boosts efficiency and reduces emissions, making it an eco-friendlier choice.

Finally, the DBT39 takes it a step further with a powerful output of up to 39,000 BTUs, perfect for heating expansive areas. It features a sleek design that fits seamlessly into various home aesthetics, whether modern or traditional. Notably, the DBT39 is designed with multiple burning modes, allowing users to choose between high heat for quick warmth or lower settings for prolonged, even heat. Its innovative heat exchanger design improves heat transfer, ensuring maximum efficiency while lowering fuel consumption.

All three models utilize Vermont Castings' renowned cast iron construction, which not only enhances durability but also improves heat retention. They also come equipped with safety features such as a built-in heat shield to prevent overheating, ensuring peace of mind for users.

In summary, the Vermont Castings DBT series – DBT33, DBT36, and DBT39 – offers a range of options tailored to various heating needs. Their combination of stylish design, robust performance, and advanced technologies sets them apart in the market, appealing to homeowners who value both functionality and aesthetics in their heating solutions. With Vermont Castings, warmth and elegance go hand in hand.