Vermont Casting 2170 manual Specifications, Seneca, Model

Page 3

Dutchwest Seneca

Specifications

17" (430mm)

27"

(685mm)

23¹⁄₂"

(597mm)

15¹⁄₂" (395mm)

26¹⁄₂"

(673mm)

20¹⁄₂"

(520mm)

22³⁄₄" (580mm)

22" (559mm)

 

 

6063

 

 

 

 

 

Seneca, Model 2170

EPA Emissions rating

2.1 gph**

EPA Efficiency rating

72.0%**

Efficiency rating

72.0%***

Range of heat output

9,400 to 22,800 BtuÕs/hr.**

Maximum heat output

33,960

BtuÕs/hr.*

Maximum burn time

8 hours

Area heated

1,400 Square feet (132m2)

Fuel Size/type

18Ó (460mm) wood logs

Fuel capacity

23 (10.4 kg.) pounds

Loading

Front or top

Chimney Connector

6Ó (150mm)

Chimney Flue Size

6Ó (150mm)

Flue exit position

Reversible, Top or Rear

Ash handling system

Removable ash pan

Glass panels

High-temperature ceramic

Weight

375 lbs. (171kg.)

Width (leg to leg)

22Ó (560mm)

Depth (leg to leg)

15¹⁄₂Ó (395mm)

Height to top of flue collar

 

 

w/5Ó standard legs

Top exit: 26¹⁄₂Ó (675mm)

.........................................

Rear exit: 27Ó (690mm)

w/Pedestal

Top exit: 30¹⁄₂Ó (775mm)

.........................................

Rear exit: 31Ó (790mm)

*Maximum heat output based on laboratory testing using full loads of seasoned hardwood.

**Based on EPA emission testing standards.

***Based on State of Oregon testing standards.

Fig. 1 Seneca specifications.

2006063

3

Image 3
Contents Seneca Accessories Table of ContentsSeneca, Model SpecificationsInstallation Chimney TypesMasonry Chimneys Chimney Height Chimney Connector GuidelinesAssembling the Chimney Connector Prefabricated ChimneysSecuring the Connector To a Prefabricated Chimney Securing the Connector to a Masonry ChimneyFreestanding Installations Fireplace Installations Above the Fireplace Fireplace Installations Through the FireplaceWall Pass-Throughs Wall pass-through enclosed with noncombustible materials Floor ProtectionKeep the Stove a Safe Distance from Surrounding Materials Floor Protection for FireplaceSafe Ways to Reduce Clearances Wall ShieldsFireplace and Mantel Trim Shields Fireplace and Mantel Trim Clearances Parallel to Wall Stove InstalledHeat shield, no connector Shields on connector1,2Seneca Clearance Diagrams Wall Shield Requirements for Common Seneca Installations InCorner Parallel to Wall Unpack the Parts AssemblyInstall Catalytic Probe Install Air Duct for Outside AirOperation Seneca Control Settings Burn Rate Primary Air Combustor Air Use the Air Control Settings That Work Best for YouStarting and Maintaining a Wood Fire How to Build a Wood Fire Keep it GoingHigh-Efficiency Wood Burning With Catalytic Combustion Conditioning Your StoveYou will soon find out that this stove is HOT While Reloading and Reviving a Wood Fire Remove and Store Ash SafelyAlways Dispose of Ash in a Safe Manner Maintenance Cleaning the GlassTest And Repair the Door Gaskets Replace Broken Glass Immediately Damper AdjustmentRepair Missing Cement in Seams Avoid Damaging the Glass Door PanelWhen to Suspect a Combustor Problem Care of the Catalytic CombustorRemove and Inspect the Combustor Watch for Better Results Maintenance Schedule Chimney ConnectorStove Catalytic Combustor Draft Management Creosote Draft TestingSingle Venting FuelHow to Obtain Service Warranty