Desa Tech RFP28TC Thermostat Sensing Bulb, Installation Options, Mounting Heater to Wall

Page 10

VENT-FREE RADIANT FLAME® HEATER

INSTALLATION

Continued

THERMOSTAT SENSING BULB

The thermostat sensing bulb has been placed inside the heater for protection during shipping.

Locating Thermostat Sensing Bulb

1.Remove front panel of heater (see Fig- ure 2, page 4).

2.Locate thermostat sensing bulb just under burner assembly.

IMPORTANT: Attach thermostat sensing bulb to back of heater for proper operation.

Attaching Thermostat Sensing Bulb

1.Remove thermostat sensing bulb from holders inside heater. Route through slot opening in bottom of heater.

2.Place clamp on thermostat sensing bulb as shown in Figure 11. Clamp is pro- vided in hardware package.

3.Snap clamp into upper mounting hole as shown in Figure 11. Mounting hole is located on lower left edge on back of heater. Make sure the thermostat sensing bulb is pointing up.

Thermostat

Sensing Bulb

Clamp

Figure 11 - Attaching Thermostat Sensing Bulb

INSTALLATION OPTIONS

There are three options for mounting this heater.

A.Mounting heater to wall

B.Mounting heater to optional hearth base

C.Mounting heater with optional hearth base to optional mantel

A. MOUNTING HEATER TO WALL

Mounting Bracket

The mounting bracket is located on back panel of heater. It has been taped there for shipping. Remove mounting bracket from back panel.

Mounting

Bracket

Figure 12 - Mounting Bracket Location

Methods For Attaching Mounting Bracket To Wall

Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 16 inches apart from their centers. Attach mounting bracket to wall in one of two ways.

1.Attaching to wall stud

2.Attaching to wall anchor

Attaching To Wall Stud This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.

Attaching To Wall Anchor This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).

Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.

Marking Screw Locations

1.Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.

WARNING: Maintain minimum clearances shown in Figure 13. If you can, provide greater clear- ances from floor and joining wall.

2.Mark screw locations on wall (see Fig- ure 13).

Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only.

3.Remove tape and mounting bracket from wall.

11"

16"

Min.

 

AdjoiningWall

 

Only Insert Mounting

20 3/4"

Screws Through Last

Min.

Hole On Each End

 

Floor

 

Figure 13 - Mounting Bracket Clearances

Attaching Mounting Bracket to Wall

Note: Wall anchors, mounting screws, and spacers are in hardware package. The hard- ware package is provided with heater.

Attaching To Wall Stud Method

For attaching mounting bracket to wall studs.

1.Drill holes at marked locations using 9/64" drill bit.

2.Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall.

3.Insert mounting screws through bracket and into wall studs.

4.Tighten screws until mounting bracket

is firmly fastened to wall studs.

10

103509

Image 10
Contents OWNER’S Operation and Installation Manual RFP28TC What to do if YOU Smell GASSafety Information VENT-FREE Radiant Flame HeaterLocal Codes Product FeaturesProduct Identification UnpackingAssembling Heater AssemblyInstalling Log Removing Front Panel Of HeaterAssembling and Attaching Brass Trim Assembling Brass TrimUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Locating Heater InstallationInstallation Items Check GAS TypeThermostat Sensing Bulb Installation OptionsMounting Heater to Wall Attaching To Wall Anchor Method Installing Bottom Mounting ScrewsPlacing Heater On Mounting Bracket Mounting Heater with Mounting Heater onOptional Hearth Base To Optional MantelConnecting to GAS Supply Installing Mantel to HeaterChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Test Pressures In Excess Of 1/2 PsigLighting Instructions For Your Safety Read Before LightingOperating Heater To Turn OFF GAS To ApplianceThermostat Control Operation Manual Lighting ProcedureInspecting Burner Pilot Flame PatternTroubleshooting Observed Problem Possible Cause RemedyObserved Problem Possible Cause Top Gas leak. See Warning statement atService Hints Cleaning and MaintenanceSpecifications Technical ServiceParts not Under Warranty Replacement Parts Parts CentralsParts Under Warranty Four Flags Power ProductsIllustrated Parts Breakdown RFP28TCParts List KEY Part Number DescriptionAccessories 103509 Warranty Information

RFP28TC specifications

Desa Tech RFP28TC is an advanced piece of technology that stands out in today’s competitive market. This robust device is designed to meet the diverse needs of various industries, from manufacturing to healthcare, ensuring efficient operations and seamless functionality.

One of the main features of the RFP28TC is its high processing power and speed. Equipped with a state-of-the-art processor, it can handle multiple tasks simultaneously without any lag. This enhances productivity, allowing businesses to maximize their output and minimize downtime.

The RFP28TC is built using cutting-edge technologies that ensure durability and reliability. Its robust chassis is designed to withstand harsh working conditions, making it ideal for environments such as factories and distribution centers. Furthermore, its energy-efficient design helps reduce operational costs, contributing to sustainability efforts while providing consistent performance.

In terms of connectivity, the RFP28TC offers a variety of options, including Wi-Fi, Bluetooth, and Ethernet. This versatility allows for seamless integration into existing networks, enabling real-time data sharing and communication across devices. Such a feature is particularly beneficial for companies looking to implement Internet of Things (IoT) solutions, where interconnected devices work together to optimize efficiency.

The user interface of the RFP28TC is designed with usability in mind. Featuring an intuitive touchscreen, it allows users to navigate through various applications effortlessly. This ease of use reduces the learning curve for new operators and ensures that employees can get to work quickly.

Another notable characteristic of the RFP28TC is its comprehensive support for various software applications. Whether it’s for inventory management, data analytics, or customer relationship management, the device supports a wide range of platforms, making it suitable for different sectors. This flexibility means that businesses can customize their technology to fit their specific needs.

Security is a top concern for many organizations, and the RFP28TC addresses this with advanced encryption and access control features. These security measures protect sensitive information, ensuring compliance with industry regulations and safeguarding against potential threats.

In conclusion, the Desa Tech RFP28TC is a powerful and flexible solution that combines high performance, robust design, and advanced connectivity. Its user-friendly interface and extensive software compatibility make it an invaluable tool for businesses across various industries, driving efficiency and innovation while prioritizing security and reliability.