Desa Tech CHDV34NA, CHDV34PA installation manual Venting with Two 90 Elbows

Page 11

OWNER’S MANUAL

VENTING

INSTALLATION

Continued

 

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H1)

Horizontal (H1) +

 

 

Horizontal (H2)

5' min.

2' max.

6' max.

6' min.

4' max.

12' max.

7' min.

6' max.

18' max.

8' min.

8' min.

20' max.

20' max.

8' max.

20' max.

Figure 19 - Horizontal Termination Configuration for Rigid Venting Using Two 90° Elbows

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H1) +

 

Horizontal (H2)

5' min.

6' max.

6' min.

12' max.

7' min.

18' max.

8' min.

20' max.

20' max.

20' max.

Figure 20 - Horizontal Termination Configuration for Rigid Venting Using Two 90° Elbows with Termination at 90° with Fireplace

Continued

105983

11

Image 11
Contents Natural GAS Model CHDV34NA PROPANE/LP GAS Model CHDV34PA For Your SafetyFor Your Safety What to do if YOU Smell GAS CHDV34NA, PA DIRECT-VENT Fireplace NATURAL/PROPANE/LP Safety InformationGlossary Terms Product FeaturesProduct Identification Local CodesFraming and Finishing PRE-INSTALLATION PreparationLocation and Space Requirements ClearancesLocation of Vent Termination General VentingGeneral Venting Installing Vent System in a Chase Venting InstallationInstallation Precautions Installation PlanningSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Cathedral Ceiling Installation Installation for Vertical TerminationFlat Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsNumber Description High Altitude InstallationParts Lists for Venting Kits and Components Comfort Glow Rigid VentingAvailable from Simpson Dura-Vent Only Comfort Glow Flexible VentingSimpson Dura-Vent GS 4 x 6 5/8 Number Description Available from Desa InternationalCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessory Installing GA3750/CDA3620T BlowersIf your fireplace system is installed Installation Items Needed Installing GAS Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemClose manual shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsREMOVING/REPLACING Glass Door Installing Remote ReceiverInstalling Rear Brick Panel and Retainer Brackets Installing Optional Brick Liner CD8037AInstalling Log No Installing LOGS, Lava Rock and Glowing EmbersLighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceCghrct Series Operation Optional Remote OperationThermostat Control Operation Cghrc Series OperationOperating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementTechnical Service Replacement PartsService Hints Wiring DiagramCHDV34NA CHDV34PA Illustrated Parts BreakdownDIRECT-VENT Fireplace CHDV34NA CHDV34PA Parts ListAccessories GMC13F Series Stained Oak Veneer Cabinet MantelHearth Base GMC11F Series Walnut Finished Hardwood VeneerWarranty Information

CHDV34PA, CHDV34NA, CHDV34PA specifications

The Desa Tech CHDV34NA, CHDV34PA, and CHDV34P are advanced heating solutions that combine efficiency, reliability, and modern technology to meet the needs of today's consumers. Each model is designed to provide optimal heating while ensuring safety and ease of use, making them ideal for both residential and commercial applications.

One of the standout features of the CHDV34 series is its impressive heating capacity. With a thermal efficiency that exceeds industry standards, these units can heat up spaces quickly while minimizing energy consumption. This makes them an attractive option for those looking to reduce their energy bills without sacrificing comfort. The versatile design allows for installation in various settings, whether in living rooms, offices, or commercial spaces.

The CHDV34NA model is particularly noteworthy for its natural gas operation, making it an eco-friendly choice. Natural gas provides a clean-burning fuel option that lowers carbon emissions compared to traditional heating methods. This model comes equipped with advanced safety features, including a built-in oxygen depletion sensor, ensuring that the unit operates safely by shutting off if oxygen levels become too low.

In contrast, the CHDV34PA model runs on propane, making it a flexible alternative for those who may not have access to natural gas lines. This model shares many of the same high-efficiency features as its natural gas counterpart, offering an easy transition for users looking to switch fuel sources.

Both models utilize an innovative electronic ignition system, which enhances reliability by eliminating the need for a standing pilot light. This technology not only saves energy but also simplifies the ignition process, allowing users to enjoy a swift heating experience.

Moreover, the CHDV34PA model is compatible with a range of optional accessories, including remote controls and programmable thermostats, allowing for personalized heating management. This level of customization ensures comfort and convenience, as users can easily adjust their settings according to their specific needs.

Overall, the Desa Tech CHDV34NA, CHDV34PA, and CHDV34P models are designed with modern consumers in mind. Their blend of efficiency, eco-friendliness, and advanced features make them stand out in the market, providing reliable heating solutions that cater to a variety of lifestyles and preferences. Whether opting for natural gas or propane, users can trust these models to deliver on performance while maintaining cost-effectiveness and safety.