Desa Tech CHDV34NA, CHDV34PA REMOVING/REPLACING Glass Door, Installing Remote Receiver

Page 21

OWNER’S MANUAL

FIREPLACE INSTALLATION

Continued

INSTALLING OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL - CGHRC SERIES/CGHRCT SERIES

NOTICE: Use only alkaline bat- teries (not included).

Installing Remote Receiver

1.Open bottom louver and locate the switch bracket on the left.

2.Unscrew the switch bracket. Lean bracket forward so you are able to ac- cess the back of the remote receiver.

3.Locate the battery clip mounted on the back of the receiver. Slide a 9-volt al- kaline battery (not included) through the clip.

4.Attach the terminal wires to the battery.

5.Remove wire from TH to TPTH on control valve (see Figure 40).

6.Connect wires from receiver to TH and TPTH to control valve (see Figure 41).

7.Replace the switch bracket.

Figure 40 - Disconnecting TH to TPTH Wire

To

Optional

Remote

Accessory

Figure 41 - Control Valve Terminals

Receiver

Terminal

Wires

Battery Clip

9-Volt Alkaline

Battery

Figure 42 - Attaching Alkaline Battery to Receiver

Installing 9-Volt Alkaline Battery

in Hand-Held Remote Control

Unit

1.Remove battery cover on back of re- mote control unit.

2.Attach terminal wires to a 9-volt alka- line battery (not included). Place bat- tery into the battery housing.

3.Replace battery cover onto remote con- trol unit.

Battery

Cover

Terminal

Remote

Wires

Control Unit

9-Volt Alkaline Battery

Battery

Housing

Figure 43 - Installing Alkaline Battery in Hand-Held Remote Control Unit

REMOVING/REPLACING GLASS DOOR

You must remove glass door to install op- tional brick liners, logs, lava rock, and em- ber material.

CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For re- placement part information see Replacement Parts, page 31.

1.Remove the upper louver panel by lift- ing upward and out (see Figure 44).

2.Remove the screws from the three tabs at the top of the glass door while hold- ing door securely keeping it from fall- ing forward.

3.Grasp door by both sides and ease it upward off of the lower bracket (see Figure 45).

4.To replace glass door, follow the above instructions in reverse.

Attaching Magnetic Decorative

Brass Strips

(Optional Installation)

Before attaching strips to fireplace, remove plastic film from brass pieces. After install- ing door, attach these strips to the top and bottom of glass door frame.

Top Louver

Panel

Figure 44 - Removing Top Louver Panel

Screw

Glass

Door

Assembly

Lower Bracket for

Glass Door Assembly

Figure 45 -Removing/ReplacingGlassDoor

Continued

105983

21

Image 21
Contents For Your Safety For Your Safety What to do if YOU Smell GASNatural GAS Model CHDV34NA PROPANE/LP GAS Model CHDV34PA CHDV34NA, PA DIRECT-VENT Fireplace NATURAL/PROPANE/LP Safety InformationProduct Identification Product FeaturesLocal Codes Glossary TermsLocation and Space Requirements PRE-INSTALLATION PreparationClearances Framing and FinishingLocation of Vent Termination General VentingGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsParts Lists for Venting Kits and Components High Altitude InstallationComfort Glow Rigid Venting Number DescriptionSimpson Dura-Vent GS 4 x 6 5/8 Comfort Glow Flexible VentingNumber Description Available from Desa International Available from Simpson Dura-Vent OnlyInstalling Optional Blower Accessory Fireplace InstallationInstalling GA3750/CDA3620T Blowers Check GAS TypeIf your fireplace system is installed Installation Items Needed Installing GAS Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsClose manual shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsREMOVING/REPLACING Glass Door Installing Remote ReceiverInstalling Rear Brick Panel and Retainer Brackets Installing Optional Brick Liner CD8037AInstalling Log No Installing LOGS, Lava Rock and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsThermostat Control Operation Optional Remote OperationCghrc Series Operation Cghrct Series OperationPilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementService Hints Replacement PartsWiring Diagram Technical ServiceCHDV34NA CHDV34PA Illustrated Parts BreakdownDIRECT-VENT Fireplace CHDV34NA CHDV34PA Parts ListAccessories Hearth Base Cabinet MantelGMC11F Series Walnut Finished Hardwood Veneer GMC13F Series Stained Oak VeneerWarranty Information

CHDV34PA, CHDV34NA, CHDV34PA specifications

The Desa Tech CHDV34NA, CHDV34PA, and CHDV34P are advanced heating solutions that combine efficiency, reliability, and modern technology to meet the needs of today's consumers. Each model is designed to provide optimal heating while ensuring safety and ease of use, making them ideal for both residential and commercial applications.

One of the standout features of the CHDV34 series is its impressive heating capacity. With a thermal efficiency that exceeds industry standards, these units can heat up spaces quickly while minimizing energy consumption. This makes them an attractive option for those looking to reduce their energy bills without sacrificing comfort. The versatile design allows for installation in various settings, whether in living rooms, offices, or commercial spaces.

The CHDV34NA model is particularly noteworthy for its natural gas operation, making it an eco-friendly choice. Natural gas provides a clean-burning fuel option that lowers carbon emissions compared to traditional heating methods. This model comes equipped with advanced safety features, including a built-in oxygen depletion sensor, ensuring that the unit operates safely by shutting off if oxygen levels become too low.

In contrast, the CHDV34PA model runs on propane, making it a flexible alternative for those who may not have access to natural gas lines. This model shares many of the same high-efficiency features as its natural gas counterpart, offering an easy transition for users looking to switch fuel sources.

Both models utilize an innovative electronic ignition system, which enhances reliability by eliminating the need for a standing pilot light. This technology not only saves energy but also simplifies the ignition process, allowing users to enjoy a swift heating experience.

Moreover, the CHDV34PA model is compatible with a range of optional accessories, including remote controls and programmable thermostats, allowing for personalized heating management. This level of customization ensures comfort and convenience, as users can easily adjust their settings according to their specific needs.

Overall, the Desa Tech CHDV34NA, CHDV34PA, and CHDV34P models are designed with modern consumers in mind. Their blend of efficiency, eco-friendliness, and advanced features make them stand out in the market, providing reliable heating solutions that cater to a variety of lifestyles and preferences. Whether opting for natural gas or propane, users can trust these models to deliver on performance while maintaining cost-effectiveness and safety.