OWNER’S MANUAL

CLEANING AND MAINTENANCE

WARNING: Turn off fireplace and let cool before cleaning.

CAUTION: You must keep con- trol areas, burners, and circulat- ing air passageways of fireplace clean. Inspect these areas of fire- place before each use. Have fire- place inspected yearly by a quali- fied service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

GLASS DOOR

WARNING: Handle glass door panel with care. Do not strike, slam, or otherwise abuse glass. Do not operate fireplace with the glass door removed, cracked, or broken.

WARNING: Do not use abra- sive cleaners as this may damage glass. Use a nonabrasive house- hold glass cleaner to clean glass. Do not clean glass when hot.

Glass must be cleaned periodically. During start-up it is normal for condensation to form on the inside of the glass causing lint, dust, and other airborne particles to cling to the glass surface. During initial start-up a slight film may form on the glass due to paint curing. The glass should be cleaned several times with a non-ammonia, non- abrasive household cleaner and warm water after the first two weeks of operation. There- after, clean the glass two or three times during each heating season, depending on the usage and circumstances present. Refer to Removing/Replacing Glass Door on page 21 of this manual when removing glass door for cleaning.

WARNING: Only parts sup- plied by the manufacturer should be used when replacing broken or damaged glass door panel (see Replacement Parts, page 31). This glass door panel is a complete unit. No substitute materials may be used.

CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep chil- dren and pets away from glass.

If glass has been broken, carefully remove glass door (see Removing/Replacing Glass Door, page 21). Vacuum all glass pieces with a shop vac.

CAUTION: Do not vacuum if pieces are hot.

Use only the ceramic glass door replace- ment intended for this fireplace (see Re- placement Parts, page 31 for detail on or- dering). No substitutions may be made. See Removing/Replacing Glass Door, page 21 for instructions for replacing glass door.

WARNING: Do not operate fireplace with the glass door re- moved, cracked, or broken.

PILOT AND BURNERS

Remove ember material before cleaning burners and replace when cleaning is complete.

Burner and controls should be cleaned with compressed air to remove dust, dirt, or lint.

Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt, or lint.

LOGS

If you remove logs for cleaning, refer to Installing Logs, Lava Rock, and Glowing Embers, page 23, to properly replace logs.

Use a vacuum cleaner to remove any car- bon buildup on logs.

Replace log(s) if broken. See Replace- ment Parts on page 31.

Replace ember material periodically as needed. See Replacement Parts on page 31.

VENTING SYSTEM

Conduct annual inspection of the venting system following these guidelines:

1.Check areas of venting system that are exposed to the weather for corrosion (rust spots or streaks and, in extreme cases, holes). Have these items replaced imme- diately by a qualified service person.

2.Remove the vent cap and shine a flash- light into the vent. Remove any foreign material.

3.Check for evidence of excessive con- densation. Continuous condensation can cause corrosion of caps, pipes, and fittings and can be caused by having excessive lateral runs, too many el- bows, or exterior portions of the sys- tem being exposed to cold weather.

4.Inspect joints to verify that no pipe sec- tion or fitting has been disturbed and loosened. Check mechanical supports such as wall straps for rigidity.

105983

27

Image 27
Contents For Your Safety For Your Safety What to do if YOU Smell GASNatural GAS Model CHDV34NA PROPANE/LP GAS Model CHDV34PA CHDV34NA, PA DIRECT-VENT Fireplace NATURAL/PROPANE/LP Safety InformationGlossary Terms Product FeaturesProduct Identification Local CodesFraming and Finishing PRE-INSTALLATION PreparationLocation and Space Requirements ClearancesLocation of Vent Termination General VentingGeneral Venting Installing Vent System in a Chase Venting InstallationInstallation Precautions Installation PlanningSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsNumber Description High Altitude InstallationParts Lists for Venting Kits and Components Comfort Glow Rigid VentingAvailable from Simpson Dura-Vent Only Comfort Glow Flexible VentingSimpson Dura-Vent GS 4 x 6 5/8 Number Description Available from Desa InternationalCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessory Installing GA3750/CDA3620T BlowersIf your fireplace system is installed Installation Items Needed Installing GAS Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemClose manual shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsREMOVING/REPLACING Glass Door Installing Remote ReceiverInstalling Rear Brick Panel and Retainer Brackets Installing Optional Brick Liner CD8037AInstalling Log No Installing LOGS, Lava Rock and Glowing EmbersLighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceCghrct Series Operation Optional Remote OperationThermostat Control Operation Cghrc Series OperationOperating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementTechnical Service Replacement PartsService Hints Wiring DiagramCHDV34NA CHDV34PA Illustrated Parts BreakdownDIRECT-VENT Fireplace CHDV34NA CHDV34PA Parts ListAccessories GMC13F Series Stained Oak Veneer Cabinet MantelHearth Base GMC11F Series Walnut Finished Hardwood VeneerWarranty Information

CHDV34PA, CHDV34NA, CHDV34PA specifications

The Desa Tech CHDV34NA, CHDV34PA, and CHDV34P are advanced heating solutions that combine efficiency, reliability, and modern technology to meet the needs of today's consumers. Each model is designed to provide optimal heating while ensuring safety and ease of use, making them ideal for both residential and commercial applications.

One of the standout features of the CHDV34 series is its impressive heating capacity. With a thermal efficiency that exceeds industry standards, these units can heat up spaces quickly while minimizing energy consumption. This makes them an attractive option for those looking to reduce their energy bills without sacrificing comfort. The versatile design allows for installation in various settings, whether in living rooms, offices, or commercial spaces.

The CHDV34NA model is particularly noteworthy for its natural gas operation, making it an eco-friendly choice. Natural gas provides a clean-burning fuel option that lowers carbon emissions compared to traditional heating methods. This model comes equipped with advanced safety features, including a built-in oxygen depletion sensor, ensuring that the unit operates safely by shutting off if oxygen levels become too low.

In contrast, the CHDV34PA model runs on propane, making it a flexible alternative for those who may not have access to natural gas lines. This model shares many of the same high-efficiency features as its natural gas counterpart, offering an easy transition for users looking to switch fuel sources.

Both models utilize an innovative electronic ignition system, which enhances reliability by eliminating the need for a standing pilot light. This technology not only saves energy but also simplifies the ignition process, allowing users to enjoy a swift heating experience.

Moreover, the CHDV34PA model is compatible with a range of optional accessories, including remote controls and programmable thermostats, allowing for personalized heating management. This level of customization ensures comfort and convenience, as users can easily adjust their settings according to their specific needs.

Overall, the Desa Tech CHDV34NA, CHDV34PA, and CHDV34P models are designed with modern consumers in mind. Their blend of efficiency, eco-friendliness, and advanced features make them stand out in the market, providing reliable heating solutions that cater to a variety of lifestyles and preferences. Whether opting for natural gas or propane, users can trust these models to deliver on performance while maintaining cost-effectiveness and safety.