Desa Tech CHDV34NA, CHDV34PA installation manual Fireplace Installation, Check GAS Type

Page 16

CHDV34NA, PA DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

FIREPLACE INSTALLATION

NOTICE: This fireplace is in- tended for use as supplemental heat. Use this fireplace along with your primary heating system. Do not install this fireplace as your primary heat source. If you have a central heating system, you may run system's circulating blower while using fireplace. This will help circulate the heat through- out the house. In the event of a power outage, you can use this fireplace as a heat source.

WARNING: A qualified ser- vice person must install fireplace. Follow all local codes.

CAUTION: This fireplace cre- ates warm air currents. These cur- rents move heat to wall surfaces next to fireplace. Installing fire- place next to vinyl or cloth wall coverings or operating fireplace where impurities (such as to- bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.

Note: Your fireplace is designed to be used in zero clearance installations. Wall or fram- ing material can be placed directly against any exterior surface on the rear, sides, or top of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these

CHECK GAS TYPE

Use proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not install fireplace. See re- tailer where you purchased the fireplace for proper fireplace according to your gas type.

INSTALLING OPTIONAL BLOWER ACCESSORY

NOTICE: If installing blower in an existing fireplace with gas con- nections, shut off gas supply and disconnect heater from gas sup- ply. Contact a qualified service person to do this.

Attaching Thermal Switch to CDA3620T Thermostatically- Controlled Blower

When installing the CDA3620T thermo- statically-controlled blower accessory, you must first secure the thermal switch to the blower.

1.Remove the two hex head screws on the blower assembly as shown in Figure 29.

2.Place the green wire between the bot- tom hole on the thermal switch bracket and the bottom hole on the blower as- sembly. Insert one of the hex screws into all three pieces and tighten.

3.Insert the top screw through the ther- mal switch bracket and into the blower assembly. Tighten screw.

4.Connect the blue wire on the blower assembly to the right side of the ther- mal switch.

5.Connect the black wire to the left side of the thermal switch.

Installing GA3750/CDA3620T Blowers

IMPORTANT: For clarity, gas valve assem- bly and grate/burner assembly are not shown in Figures 30 through 33, page 17. They will, however, be in your fireplace when you are installing the blower. Also for clarity the firebox is shown with dotted lines.

1.Open lower louver panel or remove for easier access.

2.Place the blower against the lower rear wall of firebox outer wrapper with the exhaust port directed upward. Align the holes in the top mounting tabs of blower with holes in wall of wrapper (see Figure 30, page 17). Using the two screws provided, mount blower and tighten screws securely.

Note: For CDA3620T, make sure the thermal switch is comfortably between the back of the firebox and the blower as shown in Figure 31, page 17.

3.Be sure to securely attach all wire ter- minals to terminals on blower motor (and thermal switch where applicable) and that the screw retaining the green ground wire is tight.

4.Remove screws securing the switch plate to the bottom of the firebox and set aside.

5.Place speed control against back of this plate and push the plastic control shaft through opening (see Figure 32, page 17).

6.While supporting speed control, secure con- trol shaft with lock nut by pushing and turn- ing lock nut with pliers clockwise until tight against the plate. Place control knob pro- vided onto shaft (see Figure 32, page 17).

7.Replace plate containing the switch and tighten screws securely.

spacers can be placed directly against wall or framing material. See framing details on page 4.

Place the fireplace into position and shim with noncombustible material if needed. Nail the side flanges to the framing to secure the unit in place. There are two floor brack- ets included with each unit. Use these as an alternative method of securing the fireplace.

IMPORTANT: Make sure fireplace is level before securing. If fireplace is not level it will not work properly.

Thermal Switch

White Wire

 

with Bracket

Blower Assembly

 

Black Wire

 

Green Wire

Hex Head

Blue Wire

Screws

 

Figure 29 - Attaching Thermal Switch to CDA3620T Thermostatically-Controlled Blower Accessory

16

105983

Image 16
Contents For Your Safety What to do if YOU Smell GAS For Your SafetyNatural GAS Model CHDV34NA PROPANE/LP GAS Model CHDV34PA Safety Information CHDV34NA, PA DIRECT-VENT Fireplace NATURAL/PROPANE/LPProduct Features Product IdentificationLocal Codes Glossary TermsPRE-INSTALLATION Preparation Location and Space RequirementsClearances Framing and FinishingGeneral Venting Location of Vent TerminationGeneral Venting Venting Installation Installation PrecautionsInstallation Planning Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Vertical Termination Configurations Venting with One 90 ElbowHigh Altitude Installation Parts Lists for Venting Kits and ComponentsComfort Glow Rigid Venting Number DescriptionComfort Glow Flexible Venting Simpson Dura-Vent GS 4 x 6 5/8Number Description Available from Desa International Available from Simpson Dura-Vent OnlyFireplace Installation Installing Optional Blower AccessoryInstalling GA3750/CDA3620T Blowers Check GAS TypeIf your fireplace system is installed Installing GAS Piping to Fireplace Location Installation Items NeededConnecting Fireplace to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Close manual shutoff valve see Fig- ureInstalling Remote Receiver REMOVING/REPLACING Glass DoorInstalling Optional Brick Liner CD8037A Installing Rear Brick Panel and Retainer BracketsInstalling LOGS, Lava Rock and Glowing Embers Installing Log NoFor Your Safety Read Before Lighting Manual Lighting ProcedureOperating Fireplace Lighting InstructionsOptional Remote Operation Thermostat Control OperationCghrc Series Operation Cghrct Series OperationOperating Optional Blower Accessory Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatCleaning and Maintenance Glass DoorPilot and Burners LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement AboveReplacement Parts Service HintsWiring Diagram Technical ServiceIllustrated Parts Breakdown CHDV34NA CHDV34PAParts List DIRECT-VENT Fireplace CHDV34NA CHDV34PAAccessories Cabinet Mantel Hearth BaseGMC11F Series Walnut Finished Hardwood Veneer GMC13F Series Stained Oak VeneerWarranty Information

CHDV34PA, CHDV34NA, CHDV34PA specifications

The Desa Tech CHDV34NA, CHDV34PA, and CHDV34P are advanced heating solutions that combine efficiency, reliability, and modern technology to meet the needs of today's consumers. Each model is designed to provide optimal heating while ensuring safety and ease of use, making them ideal for both residential and commercial applications.

One of the standout features of the CHDV34 series is its impressive heating capacity. With a thermal efficiency that exceeds industry standards, these units can heat up spaces quickly while minimizing energy consumption. This makes them an attractive option for those looking to reduce their energy bills without sacrificing comfort. The versatile design allows for installation in various settings, whether in living rooms, offices, or commercial spaces.

The CHDV34NA model is particularly noteworthy for its natural gas operation, making it an eco-friendly choice. Natural gas provides a clean-burning fuel option that lowers carbon emissions compared to traditional heating methods. This model comes equipped with advanced safety features, including a built-in oxygen depletion sensor, ensuring that the unit operates safely by shutting off if oxygen levels become too low.

In contrast, the CHDV34PA model runs on propane, making it a flexible alternative for those who may not have access to natural gas lines. This model shares many of the same high-efficiency features as its natural gas counterpart, offering an easy transition for users looking to switch fuel sources.

Both models utilize an innovative electronic ignition system, which enhances reliability by eliminating the need for a standing pilot light. This technology not only saves energy but also simplifies the ignition process, allowing users to enjoy a swift heating experience.

Moreover, the CHDV34PA model is compatible with a range of optional accessories, including remote controls and programmable thermostats, allowing for personalized heating management. This level of customization ensures comfort and convenience, as users can easily adjust their settings according to their specific needs.

Overall, the Desa Tech CHDV34NA, CHDV34PA, and CHDV34P models are designed with modern consumers in mind. Their blend of efficiency, eco-friendliness, and advanced features make them stand out in the market, providing reliable heating solutions that cater to a variety of lifestyles and preferences. Whether opting for natural gas or propane, users can trust these models to deliver on performance while maintaining cost-effectiveness and safety.