Linear AM3Plus Contents, Introduction, Operation, Programming and Cardholder Maintenance

Models: AM3Plus

1 20
Download 20 pages 9.03 Kb
Page 2
Image 2

Contents

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Programming and Cardholder Maintenance. . . . . . . . . . . . . . 2

Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Software Highlights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Feature Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Accessory Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

PBUS Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Wiegand Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Component Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Important Mounting Requirements . . . . . . . . . . . . . . . . . . . . 7

AM3Plus Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Relay Output Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Power, Battery, & Ground Wiring . . . . . . . . . . . . . . . . . . . . . 10

Telephone Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

PBUS Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Wiegand Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

RS-232 Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Optional Network Connections . . . . . . . . . . . . . . . . . . . . . . .13

System Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

System Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Linear Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

FCC Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Throughout this manual, multiple-unit networks are referenced. Depending on the programming method used, networks can contain the following model units:

NETWORK MODEL OPTIONS

With AccessBase2000 Programming

With AXNET Programming

AM3Plus

AM3Plus

 

 

AE1000Plus

AE1000Plus

 

 

AE2000Plus

AE2000Plus

 

 

AM-3

 

 

 

AE-1000

 

 

 

AE-2000

 

 

 

Introduction

The AM3Plus Access Controller is designed for use as a primary access control device for gated communities, parking garages, offi ce buildings, apartments, dormitories, hotels/motels, commercial buildings and recreational facilities.

Housed in a lockable, plastic enclosure, the AM3Plus features a 2-digit LED display, nine status indicators, four relay indicators with four relay activation pushbuttons. Three programming buttons, a reset button, and a power indicator are present. The enclosure is monitored with a magnetic “tamper” switch.

The system controls its four output relays by responding to various input devices that react to proximity cards, transmitters, and entry codes. The four relay output channels can be programmed to control electric door strikes, magnetic locks, door & gate operators, or barrier gates.

Access is granted or denied depending on the current user’s authorization to gain access and system settings that control groups of users or all users. Complete access control event logging, access time restriction, access location restriction, and administration functions are also available to manage the installation.

The AM3Plus is network ready. Multiple units can be interconnected on a 3-wire RS-485 network or through modems. The AM3Plus can be used in mixed networks with its sister products, the AE1000Plus and AE2000Plus.

Two sets of Wiegand inputs are available for connection to 26, 30, or 31-bit Wiegand devices (card readers, etc.). Two sets of PBUS inputs are available for connection to Linear’s line of remote accessories.

The AM3Plus can be powered from a 12-24 Volt AC or DC source. DC power can be obtained from the access device or AC power from a separate power transformer. The system supports and charges a 12-volt backup battery for operation during power outage. Low battery detection circuitry monitors the backup battery’s condition. The EEPROM memory retains all entry codes and programming, even without power.

Operation

In a typical installation, the unit’s memory would be programmed with each resident’s name and entry code number. Arriving visitors would use a remote keypad to enter their entry code. Also proximity receivers, swipe card readers, and other remote devices can be used with the system.

Block coded MegaCode® transmitters can be used to gain access through a remote radio receiver connected to the AM3Plus PBUS. Each transmitter can be individually suspended or re-activated.

The system’s clock/calendar can control access based on specifi c times and dates. Automatic relay activation can be scheduled. Access can be restricted to certain times and dates. Holiday access can be scheduled. The system’s event log records system activity for future reference.

Programming and Cardholder Maintenance

Two programming methods can be used with the system: Linear’s AXNET or AccessBase2000. Each has its advantages, but only one must be chosen at the onset for each installation. Once a unit is programmed with one method, all programming data will be lost if a decision is made to switch to the other method.

Linear’s AXNET software is built into each unit. It allows connecting to the unit using common browser software from any PC at any location. Each unit’s database is stored in the unit’s memory.

Linear’s AccessBase2000 software installs in one dedicated PC and is designed with many extra features usually for large network installations. The database for the entire system is stored in the dedicated PC.

2

Page 2
Image 2
Linear AM3Plus installation instructions Contents, Introduction, Operation, Programming and Cardholder Maintenance