Desa Tech CGF265NVA, CGF280NT installation manual Installing Logs, Installing Front Log

Page 20

INSTALLING

Continued

20

INSTALLING LOGS

WARNING

Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Slide front log (#1) into place behind front burner. Make sure tabs at bottom of log are behind front burner (see Figure 21).

2 . Slide rear log (#2) into place behind rear burner (see Figure 22).

3.Place left front branch (#4) and right front branch (#5) (24" and 30" models) or front branch (#4) (18" model) into place (see Figure 23). Make sure notches on bottom rest on grates.

Front Log (#1)

Tab

Figure 21 - Installing Front Log

Rear Log (#2)

Left Branch (#4)

Right Branch (#5)

Figure 22 - Installing Rear Log

Figure 23 - Installing Rear Log

102664

Image 20
Contents OWNER’S Operation and Installation Manual CGF265NVA CGF280NT What to do if YOU Smell GASContents Safety Information Safety InformationProduct Identification Features Local CodesUnpacking ProductAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Unconfined SpaceDetermining AIR Flow for Fireplace Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installing Check GAS TypeAssembling and Attaching Brass Trim Assembling Brass TrimConventional Fireplace Installation Minimum Wall and Ceiling Clearances see FigureLocation of Nailing Flanges Installing Cabinet Mantel BUILT-IN Fireplace Installation Rough Opening for Installing in WallMantel Clearances for Built-In Installation Mantel ShelfInstalling GAS Piping to Fireplace Location Installation Items NeededConnecting Fireplace to GAS Supply Installation Items NeededChecking GAS Connections Attaching Flexible Gas Lines TogetherPressure Testing Fireplace Gas Connections Manual Shutoff ValveInstalling Logs Installing Front LogOperating FireplaceOperating Fireplace To Turn OFF GAS to Appliance Manually-Controlled Model Variable Control Operation Front Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Logs Trouble ShootingODS/PILOT and Burners Cleaning and Mainte TROUBLE- ShootingMaintenance, TroubleObserved Possible Remedy Problem Cause Service HintsTechnical PartsIllustrated Parts Breakdown Parts List Log Base Assembly Variable Manually Controlled ModelsCFG280NT Log Base Assembly Thermostat Controlled Models CGF265NVA CGF280NT CGF280NT CGF265NVA Accessories 102664 Warranty Information Keep this Warranty

CGF265NVA, CGF280NT specifications

The Desa Tech CGF280NT and CGF265NVA are innovative heating solutions designed for both efficiency and performance. These models combine advanced technology and user-friendly features, making them suitable for various environments, and particularly effective for residential heating needs.

The CGF280NT model is distinguished by its high-efficiency design, which allows it to deliver substantial heat output while minimizing energy consumption. One of its standout features is the Quiet Operation Technology, which significantly reduces the noise level, ensuring that your living space remains peaceful and comfortable even while the heater is in use. Additionally, it has a powerful fan that enhances heat distribution, allowing for a more consistent and comfortable temperature throughout the area.

On the other hand, the CGF265NVA model showcases a sleek, modern aesthetic that complements various interior designs. This unit is equipped with Smart Control Technology, enabling users to adjust settings from a smartphone app. This feature allows easy temperature management while improving energy efficiency. The CGF265NVA is also designed with safety in mind, integrating advanced safety features like overheat protection and an automatic shut-off system to provide peace of mind during operation.

Both models incorporate cutting-edge heat exchanger technology, which maximizes the heat output while ensuring energy savings. They boast a robust construction, with durable materials that stand up to the rigors of daily use. Furthermore, the intuitive controls on both models allow users to easily select between various heating modes, tailoring the performance to suit individual needs.

In terms of installation, both models are designed to be user-friendly, with straightforward setups that do not require extensive modifications to existing spaces. This ease of installation is complemented by their lightweight design, enabling convenient portability.

Ultimately, the Desa Tech CGF280NT and CGF265NVA are prime examples of modern heating solutions that prioritize performance, safety, and user convenience. With their advanced technologies and thoughtful design features, they represent a significant advancement in heating technology, ensuring that users enjoy a comfortable and energy-efficient environment all year round.