Desa Tech CGF280NT, CGF265NVA installation manual To Turn OFF GAS to Appliance

Page 23

OPERATING

8. Turn control knob counterclockwise

C-clockwise

to desired heating level. The

FIREPLACE

burners should light. Set control knob to any heat level between HI and LO.

 

 

 

CAUTION

Thermostat-

Controlled Model

 

Do not try to adjust heating levels by using the manual shutoff valve.

Continued

TO TURN OFF GAS TO APPLIANCE

Shutting Off Fireplace

Turn control knob clockwise Clockwise to the OFF position.

Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise Clockwise to the PILOT position.

THERMOSTAT CONTROL OPERATION

You can set the thermostat control knob to any comfort level between HI and LO. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

Note: Selecting the HI setting will cause the burner to remain on without modulating down in most cases.

MANUAL LIGHTING PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, page 22.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, above.

OPERATING

 

 

FOR YOUR SAFETY READ BEFORE LIGHTING

 

 

 

 

 

FIREPLACE

 

 

 

 

 

 

 

 

 

WARNING ICONG 001 WARNING

 

Manually-Controlled

 

If you do not follow these instructions exactly, a fire or explosion may

Model

result causing property damage, personal injury or loss of life.

CGF265NVA

 

 

 

 

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Continued 23

102664

Image 23
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation Manual CGF265NVA CGF280NTContents Safety Information Information SafetyProduct Identification Product FeaturesLocal Codes UnpackingUnconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Fireplace LocationVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallingAssembling Brass Trim Assembling and Attaching Brass TrimMinimum Wall and Ceiling Clearances see Figure Conventional Fireplace InstallationLocation of Nailing Flanges Installing Cabinet Mantel Rough Opening for Installing in Wall BUILT-IN Fireplace InstallationMantel Shelf Mantel Clearances for Built-In InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS SupplyAttaching Flexible Gas Lines Together Checking GAS ConnectionsManual Shutoff Valve Pressure Testing Fireplace Gas ConnectionsInstalling Front Log Installing LogsFireplace OperatingOperating Fireplace To Turn OFF GAS to Appliance Manually-Controlled Model Variable Control Operation Front Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Logs Trouble ShootingODS/PILOT and Burners TROUBLE- Shooting Cleaning and MainteTrouble Maintenance,Observed Possible Remedy Problem Cause Parts ServiceHints TechnicalIllustrated Parts Breakdown Log Base Assembly Variable Manually Controlled Models Parts ListCFG280NT Log Base Assembly Thermostat Controlled Models CGF265NVA CGF280NT CGF280NT CGF265NVA Accessories 102664 Keep this Warranty Warranty Information

CGF265NVA, CGF280NT specifications

The Desa Tech CGF280NT and CGF265NVA are innovative heating solutions designed for both efficiency and performance. These models combine advanced technology and user-friendly features, making them suitable for various environments, and particularly effective for residential heating needs.

The CGF280NT model is distinguished by its high-efficiency design, which allows it to deliver substantial heat output while minimizing energy consumption. One of its standout features is the Quiet Operation Technology, which significantly reduces the noise level, ensuring that your living space remains peaceful and comfortable even while the heater is in use. Additionally, it has a powerful fan that enhances heat distribution, allowing for a more consistent and comfortable temperature throughout the area.

On the other hand, the CGF265NVA model showcases a sleek, modern aesthetic that complements various interior designs. This unit is equipped with Smart Control Technology, enabling users to adjust settings from a smartphone app. This feature allows easy temperature management while improving energy efficiency. The CGF265NVA is also designed with safety in mind, integrating advanced safety features like overheat protection and an automatic shut-off system to provide peace of mind during operation.

Both models incorporate cutting-edge heat exchanger technology, which maximizes the heat output while ensuring energy savings. They boast a robust construction, with durable materials that stand up to the rigors of daily use. Furthermore, the intuitive controls on both models allow users to easily select between various heating modes, tailoring the performance to suit individual needs.

In terms of installation, both models are designed to be user-friendly, with straightforward setups that do not require extensive modifications to existing spaces. This ease of installation is complemented by their lightweight design, enabling convenient portability.

Ultimately, the Desa Tech CGF280NT and CGF265NVA are prime examples of modern heating solutions that prioritize performance, safety, and user convenience. With their advanced technologies and thoughtful design features, they represent a significant advancement in heating technology, ensuring that users enjoy a comfortable and energy-efficient environment all year round.