Kenwood KRF-X9992D An Example of SL16 Chained Connections, An Example of XS8 Chained Connections

Models: KRF-X9992D

1 145
Download 145 pages 16.99 Kb
Page 36
Image 36

Connections

Chapter One : Connecting Your Devices

Audio-Video Receiver KRF-X9992D

What if I Have Several Kenwood Devices (System Control Chaining)?

Kenwood provides convenient control of the entire system via two control modes:

SL16, which allows you to connect SL16 devices only

XS8, which allows you to connect XS, XS8, and XR devices

You cannot mix SL16 and XS8 settings. All devices connected via system control cables must use the same setting.

An Example of SL16 Chained

Connections:

To switch between the two modes :

1.Slide the selector switch (shown below) from SL16 (the factory-set default) to XS8.

2.Turn the receiver’s power switch off, and on again.

System Control connection allows you to:

Make sure the units are connected to the correct jacks on the receiver—for example, no device connected to the CD2/TAPE 2 MONITOR jacks can use a system control cable.

Some CD players and cassette decks do not support the SL16 system control mode. Do not include these devices in a set of SL16 chained connections; where appropriate, use the XS8 mode instead.

Do not mix connections of the two modes: if a device does not support the mode you are using for

 

[SL16] [XS8]

30

[SL16] [XS] [XS8]

 

[SL16]

 

[SL16] [XS] [XS8] [XR]

 

[XS]

Receiver

 

 

 

 

 

 

CD Player

SYSTEM

 

 

CONTROL

MD Recorder

cord

Tape Deck

 

 

 

 

 

 

Record Player

 

 

 

See the current status of the selected source device, such as Play or Stop (SL16 devices only).

control connected devices via the remote

switch the receiver’s input automatically to a connected device when you start playback from that device

synchronize recording a CD automatically when you start playback from the connected CD player

chaining, do not connect that device.

Do not connect system control cables to any device not specified by Kenwood. Using system control functions with a device that does not support them can damage the device.

Make sure system control plugs are firmly seated in the appropriate jacks.

An Example of XS8 Chained Connections:

[SL16] [XS8]

[SL16] [XS] [XS8]

[SL16]

[SL16] [XS] [XS8] [XR]

[XS]

Receiver

CD Player

MD Recorder

Tape Deck

Record Player

SYSTEM CONTROL cord

Page 36
Image 36
Kenwood KRF-X9992D manual An Example of SL16 Chained Connections, An Example of XS8 Chained Connections