Desa Tech CGF280NT, CGF265NVA installation manual Log Base Assembly Thermostat Controlled Models

Page 35

PARTS LIST

Log Base Assembly

Thermostat-

Controlled

Models

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 38 of this manual.

CGF280NT

KEY

 

 

 

 

NO.

PART NUMBER

DESCRIPTION

QTY.

 

 

 

 

 

 

1

102230-02

Front Log (#1)

1

 

2

102231-02

Rear Log (#2)

1

 

3

11084-38

Screw

2

 

4

101332-01

Left Front Branch (#4)

1

 

5

101333-01

Right Front Branch (#5)

1

 

6

098304-01

Screw, #10 Phillips, Black

8

 

7

100701-02

O.D.S. Pilot

1

 

7-1

098594-01

Ignitor

1

 

7-2

098593-01

Thermocouple

1

 

8

098249-01

Nut

4

 

9

101006-01

Pilot Bracket

1

 

10

101330-05

Front Burner Assembly

1

 

11

100999-02

Rear Burner Assembly

1

 

12

102256-04BR

Base Assembly

1

 

13

098271-06

Ignitor Cable

1

 

14

101924-01CB

Firebox Bottom

1

 

15

098867-09

Gas Regulator

1

 

16

101004-04

Front Burner Injector

1

 

17

102845-01

Inlet Tube

1

 

18

101382-01

Thermovalve Bracket

1

 

19

099387-03

Pilot Tube

1

 

20

102846-01

Burner Tube

1

 

21

097809-02

Adapter

1

 

22

099211-01

Screw

2

 

23

098544-01

Thermostat Clamp

1

 

24

101329-16

Thermostat Gas Valve Assembly

1

 

25

101381-01

Cover and Piezo

1

 

26

101004-01

Rear Burner Injector

1

 

27

M11084-26

Hex Screw, #10

2

 

28

101628-01

Flex Hose

1

 

 

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

 

100563-01

Warning Plate

1

 

101054-01

Lighting Instructions Plate

1

 

100565-01

Warning Plate Fastener

1

 

101416-14

Information Video

1

 

 

 

 

102664

35

Image 35
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation Manual CGF265NVA CGF280NTContents Safety Information Information SafetyProduct Identification Product FeaturesLocal Codes UnpackingUnconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Fireplace LocationVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallingAssembling Brass Trim Assembling and Attaching Brass TrimMinimum Wall and Ceiling Clearances see Figure Conventional Fireplace InstallationLocation of Nailing Flanges Installing Cabinet Mantel Rough Opening for Installing in Wall BUILT-IN Fireplace InstallationMantel Shelf Mantel Clearances for Built-In InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS SupplyAttaching Flexible Gas Lines Together Checking GAS ConnectionsManual Shutoff Valve Pressure Testing Fireplace Gas ConnectionsInstalling Front Log Installing LogsFireplace OperatingOperating Fireplace To Turn OFF GAS to Appliance Manually-Controlled Model Variable Control Operation Front Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Logs Trouble ShootingODS/PILOT and Burners TROUBLE- Shooting Cleaning and MainteTrouble Maintenance,Observed Possible Remedy Problem Cause Parts ServiceHints TechnicalIllustrated Parts Breakdown Log Base Assembly Variable Manually Controlled Models Parts ListCFG280NT Log Base Assembly Thermostat Controlled Models CGF265NVA CGF280NT CGF280NT CGF265NVA Accessories 102664 Keep this Warranty Warranty Information

CGF265NVA, CGF280NT specifications

The Desa Tech CGF280NT and CGF265NVA are innovative heating solutions designed for both efficiency and performance. These models combine advanced technology and user-friendly features, making them suitable for various environments, and particularly effective for residential heating needs.

The CGF280NT model is distinguished by its high-efficiency design, which allows it to deliver substantial heat output while minimizing energy consumption. One of its standout features is the Quiet Operation Technology, which significantly reduces the noise level, ensuring that your living space remains peaceful and comfortable even while the heater is in use. Additionally, it has a powerful fan that enhances heat distribution, allowing for a more consistent and comfortable temperature throughout the area.

On the other hand, the CGF265NVA model showcases a sleek, modern aesthetic that complements various interior designs. This unit is equipped with Smart Control Technology, enabling users to adjust settings from a smartphone app. This feature allows easy temperature management while improving energy efficiency. The CGF265NVA is also designed with safety in mind, integrating advanced safety features like overheat protection and an automatic shut-off system to provide peace of mind during operation.

Both models incorporate cutting-edge heat exchanger technology, which maximizes the heat output while ensuring energy savings. They boast a robust construction, with durable materials that stand up to the rigors of daily use. Furthermore, the intuitive controls on both models allow users to easily select between various heating modes, tailoring the performance to suit individual needs.

In terms of installation, both models are designed to be user-friendly, with straightforward setups that do not require extensive modifications to existing spaces. This ease of installation is complemented by their lightweight design, enabling convenient portability.

Ultimately, the Desa Tech CGF280NT and CGF265NVA are prime examples of modern heating solutions that prioritize performance, safety, and user convenience. With their advanced technologies and thoughtful design features, they represent a significant advancement in heating technology, ensuring that users enjoy a comfortable and energy-efficient environment all year round.