Desa Tech CGF280NT, CGF265NVA Connecting Fireplace to GAS Supply, Installation Items Needed

Page 17

INSTALLING

Continued

A.G.A. Design-Certified Manual Shutoff Valve

With 1/8" NPT Tap*

Approved

Flexible

Gas Line

 

 

From Gas Meter

3" Minimum

(5" W.C. to 10.5" W.C.

 

Pressure)

 

 

 

 

 

Sediment

 

 

Tee Joint

Trap

 

 

 

 

 

Pipe Nipple

 

Figure 16 - Gas Connection

Cap

 

 

 

*Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 38.

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed

5/16" hex socket wrench or nut-driver

Phillips screwdriver

sealant (resistant to LP gas, not provided)

1.Remove fireplace screen. Remove two screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove.

2.Remove access door from rear or side of fireplace. See Product Identification, page 4, for access door locations.

3.Remove screws that attach log base assembly to fireplace (see Figure 17). Carefully lift up log base assembly and remove from fireplace (see Figure 17).

CAUTION

WARNING ICON

G 001

Do not pick up log base assembly by burners. This could damage burners. Only handle base by grates.

Continued

Figure 17 - Removing Log Base Assembly From Fireplace

17

102664

Image 17
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation Manual CGF265NVA CGF280NTContents Safety Information Information SafetyProduct Identification Local Codes FeaturesUnpacking ProductProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Fireplace LocationVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallingAssembling Brass Trim Assembling and Attaching Brass TrimMinimum Wall and Ceiling Clearances see Figure Conventional Fireplace InstallationLocation of Nailing Flanges Installing Cabinet Mantel Rough Opening for Installing in Wall BUILT-IN Fireplace InstallationMantel Shelf Mantel Clearances for Built-In InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS SupplyAttaching Flexible Gas Lines Together Checking GAS ConnectionsManual Shutoff Valve Pressure Testing Fireplace Gas ConnectionsInstalling Front Log Installing LogsFireplace OperatingOperating Fireplace To Turn OFF GAS to Appliance Manually-Controlled Model Variable Control Operation Front Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Logs Trouble ShootingODS/PILOT and Burners TROUBLE- Shooting Cleaning and MainteTrouble Maintenance,Observed Possible Remedy Problem Cause Hints ServiceTechnical PartsIllustrated Parts Breakdown Log Base Assembly Variable Manually Controlled Models Parts ListCFG280NT Log Base Assembly Thermostat Controlled Models CGF265NVA CGF280NT CGF280NT CGF265NVA Accessories 102664 Keep this Warranty Warranty Information

CGF265NVA, CGF280NT specifications

The Desa Tech CGF280NT and CGF265NVA are innovative heating solutions designed for both efficiency and performance. These models combine advanced technology and user-friendly features, making them suitable for various environments, and particularly effective for residential heating needs.

The CGF280NT model is distinguished by its high-efficiency design, which allows it to deliver substantial heat output while minimizing energy consumption. One of its standout features is the Quiet Operation Technology, which significantly reduces the noise level, ensuring that your living space remains peaceful and comfortable even while the heater is in use. Additionally, it has a powerful fan that enhances heat distribution, allowing for a more consistent and comfortable temperature throughout the area.

On the other hand, the CGF265NVA model showcases a sleek, modern aesthetic that complements various interior designs. This unit is equipped with Smart Control Technology, enabling users to adjust settings from a smartphone app. This feature allows easy temperature management while improving energy efficiency. The CGF265NVA is also designed with safety in mind, integrating advanced safety features like overheat protection and an automatic shut-off system to provide peace of mind during operation.

Both models incorporate cutting-edge heat exchanger technology, which maximizes the heat output while ensuring energy savings. They boast a robust construction, with durable materials that stand up to the rigors of daily use. Furthermore, the intuitive controls on both models allow users to easily select between various heating modes, tailoring the performance to suit individual needs.

In terms of installation, both models are designed to be user-friendly, with straightforward setups that do not require extensive modifications to existing spaces. This ease of installation is complemented by their lightweight design, enabling convenient portability.

Ultimately, the Desa Tech CGF280NT and CGF265NVA are prime examples of modern heating solutions that prioritize performance, safety, and user convenience. With their advanced technologies and thoughtful design features, they represent a significant advancement in heating technology, ensuring that users enjoy a comfortable and energy-efficient environment all year round.