Desa Tech CGD3930PT, CGD3924PT installation manual I004, Shut off gas supply

Page 3

SAFETY INFORMATION

Continued

I0_04

WARNINGS Continued

WARNING: Any change to this heater or its controls can be dangerous. "

1.This appliance is only for use with the type of gas indicated on the rating plate. Thi: appliance is not convertible for use with other gases,

2.Do not place propane (LP) supply tank(s) inside any structure. Locate propane (LP) supply tank(s) outdoors.

3.To prevent performance problems, do not use propane fuel tank ofless than 100 lbs. capacity.

4.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor' s phone. Follow the gas supplier' s instructions

if you cannot reach your gas supplier, call the fire department

5.This heater shall not be installed in a bedroom or bathroom unless installed as a vented appliance (Variable Manually-Controlled Models Only) (see page 13).

6.Never install the heater

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

7.Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage. If damaged, operate heater with flue damper closed.

8.If fireplace has glass doors, never operate this heater with glass doors closed. Ifyou operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

9.You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

!0. This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and heater burning manufacturing residues.

11.Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered

burner patterns can cause sooting.

12, Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater.

13.This heater needs fresh, outside air ventilation to run properly. This heater has an oxygen depletion sensor (ODS) pilot light safety system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 5 through 8. If heater keeps shutting off, see Troubleshooting, pages 25 through 28.

14.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

15.Do not use this heater to cook food or burn paper or other objects.

16.Never place any objects on the heater.

17.Heater base assembly becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for atime after shutdown. Allow surface to cool before touching.

18.Carefully supervise young children when they are in the room with heater.

19.Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the c onU'ol system and any gas control which has been under water.

20.Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime- sized or larger).

21.Turn heater off and let cool before servicing. Only a qualified service person should service and repair heater.

22. Operating heater above elevations of 4,500 feet could cause pilot outage,

m_

Image 3
Contents Patent Pending Owners Operation and Installation ManualSection Safety InformationShut off gas supply I004Crossover Log Front Log Ignitor Contr¢ Safety PilotProduct Local CodesUnusually Tight Construction AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Heater LocationAIR for Combustion Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallingLog Minimum Firebox Size Height Depth Front Width 14 = Minimum Fireplace Clearance To Combustible MaterialsLog Size Side Wall Ceiling 18,24,30 LOG Sizing RequirementsIf Not Using Mantel Minimum Non-Combustible Material ClearancesHeat Resistant Material Non-Combustible Material Distance a Or more Minimum Non-Combustible Material Clearances If Using MantelRequirements for Safe Installation Mantel ClearancesMin Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Combustible MaterialInstalling Damper Clamp Accessory for Vented Operation Masonry Fireplace Manufactured FireplaceIll Installing Installing Heater Base Assembly Installation Items NeededRegulator Piping check local codes Installation Items NeededExternal SeePropane Reou,atorMinimum Checking GAS ConnectionsFrom Gas Meter C*** to Gas HoseTo..-= Pressure Testing Heater Gas ConnectionsTest Pressures Equal To or Less Than 1/2 Psig Shutoff Valve SedFront Log #3 Notches Installing Logs%,% Cutut SlotOperating Heater IgnitorButlon \Knob Press Turn Control knob clockwise To the High OperatingDo not operate heater between Pilot and High positions Shutting Off HeaterLighting Instructions IgnitorElectrode Thermocouple Operating HeaterPilot Flame PAIrERN Inspecting BurnersTurn control knob clockwise To the Pilot position Thermostat-Controlled Models OnlyTROUBLE- Shooting Cleaning MaintenanceCompany Observed ProblemPossible Cause PaneRemedy Observed Possible Problem CauseTrouble ShootingObserved Problem Possible Causeremedy Gas odor even when control knob is in OFFGas leak. See Warning statement at top MountingThermostat Sensing BulbScrew Retaining Claml Sensing Bulb Glass Doors ThermostatLModel Models Btu Variable SpecificationsWhen gas pressure is too low Pilot will not stay lit When gas quality is badFBD Replacement Parts CentralParts Under Warranty Parts Not Under WarrantyAccessories Black FireplaceHood GA6050 1715 Illustrated Parts BreakdownDescription Part Number20-1 CGD3924PT CGD3930PT100639-01 100563-01101054-01 100565-01Page Page Industrial Ddve Box Bowling Green, KY Keep this WarrantyDate Purchased To you

CGD3924PT, CGD3930PT specifications

The Desa Tech CGD3924PT and CGD3930PT are sophisticated heating solutions designed to provide warmth and comfort in various residential settings. These models reflect the company's commitment to quality, efficiency, and user-friendliness, making them ideal for homeowners seeking reliable heat sources during colder months.

One of the standout features of both the CGD3924PT and CGD3930PT is their powerful heating capability. The CGD3924PT boasts an impressive heat output of 24,000 BTUs, while the CGD3930PT offers a robust 30,000 BTUs, ensuring they can effectively warm larger spaces quickly. This makes them suitable for living rooms, basements, and even commercial settings where efficient heating is crucial.

Both models are equipped with advanced infrared technology, which allows for more efficient heat distribution. This technology ensures that warmth is evenly dispersed throughout the room, minimizing cold spots and enhancing comfort. Additionally, the infrared heating process is known for being energy-efficient, translating to lower energy bills for the homeowner.

User convenience is another focus of the Desa Tech CGD series. Each unit is designed with an easy-to-use control panel that allows for simple adjustment of the temperature settings. This intuitive interface, combined with features like a remote control on the CGD3930PT, offers users the ability to manage their heating preferences effortlessly from anywhere in the room.

Safety is paramount, and Desa Tech takes it seriously. Both models feature an automatic shut-off mechanism that activates under specific conditions, providing peace of mind to users, especially in households with children or pets. In addition, the units incorporate a built-in oxygen depletion sensor, which ensures that the unit operates safely in enclosed spaces by shutting off if oxygen levels drop too low.

The aesthetic design of the CGD3924PT and CGD3930PT is another noteworthy characteristic. Both models feature a sleek, modern finish that can complement a variety of interior decor styles. They can be easily integrated into existing home designs without compromising overall aesthetics.

In summary, the Desa Tech CGD3924PT and CGD3930PT are powerful, efficient, and user-friendly heating solutions. With their advanced infrared technology, considerable heat outputs, straightforward controls, safety features, and attractive designs, they stand out as excellent choices for anyone looking to improve their home heating experience. Whether you’re seeking to warm up a cozy living space or a larger commercial area, these units deliver performance and reliability, making them worthy investments for any homeowner.