Desa Tech CGD3930PT, CGD3924PT installation manual Operating Heater, IgnitorElectrode Thermocouple

Page 23

OPERATING HEATER

Thermostatically- Controlled Models

Continued

1.STOP! Read the safety information above.

2.Make sure manual shutoff valve is fully open.

3. Turn control knob clockwise _

to the OFF position.

. g!LniW

ignitor Button.__"

_

_

_COntrOI

KnOb

Figure 23 - Control Knob and Ignitor Button Location

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.

5. Turn control

knob counterclockwise _

to the PILOT position. Press in

control knob

for five (5) seconds (see above).

 

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or less. This will allow air to bleed from the gas system.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, press and release ignitor button. This will light pilot.

The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure on page 24.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety inter. lock system. Walt one (1) minute for system to reset before lighting pilot again.

IgnitorElectrode

Thermocouple_

_

mer

_

Figure 24 - Pilot

8.Turn control knob counterclockwise _ burners should light. Set control knob to

to desired heating level. The any heat level between HI and LO.

CAUTION

i

Do not try to adjust heating levels by using the manual shutoff.valve.

Continued I

10_04

Image 23
Contents Patent Pending Owners Operation and Installation ManualSection Safety InformationShut off gas supply I004Crossover Log Front Log Ignitor Contr¢ Safety PilotProduct Local CodesUnusually Tight Construction AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Heater LocationVentilation Air From Inside Building AIR for CombustionVentilation AIR Check GAS Type InstallingLog Minimum Firebox Size Height Depth Front Width 14 = Minimum Fireplace Clearance To Combustible MaterialsLog Size Side Wall Ceiling 18,24,30 LOG Sizing RequirementsHeat Resistant Material If Not Using MantelMinimum Non-Combustible Material Clearances Non-Combustible Material Distance a Or more Minimum Non-Combustible Material Clearances If Using MantelRequirements for Safe Installation Mantel ClearancesMin Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Combustible MaterialIll Installing Damper Clamp Accessory for Vented OperationMasonry Fireplace Manufactured Fireplace Regulator Installing Installing Heater Base AssemblyInstallation Items Needed Piping check local codes Installation Items NeededExternal SeePropane Reou,atorMinimum Checking GAS ConnectionsFrom Gas Meter C*** to Gas HoseTo..-= Pressure Testing Heater Gas ConnectionsTest Pressures Equal To or Less Than 1/2 Psig Shutoff Valve SedFront Log #3 Notches Installing Logs%,% Cutut SlotKnob Operating HeaterIgnitorButlon \ Press Turn Control knob clockwise To the High OperatingDo not operate heater between Pilot and High positions Shutting Off HeaterLighting Instructions IgnitorElectrode Thermocouple Operating HeaterPilot Flame PAIrERN Inspecting BurnersTurn control knob clockwise To the Pilot position Thermostat-Controlled Models OnlyTROUBLE- Shooting Cleaning MaintenanceCompany Observed ProblemPossible Cause PaneRemedy Observed Possible Problem CauseTrouble ShootingGas leak. See Warning statement at top Observed Problem Possible CauseremedyGas odor even when control knob is in OFF Screw Retaining Claml Sensing Bulb MountingThermostatSensing Bulb Glass Doors ThermostatLModel Models Btu Variable SpecificationsWhen gas pressure is too low Pilot will not stay lit When gas quality is badFBD Replacement Parts CentralParts Under Warranty Parts Not Under WarrantyHood GA6050 AccessoriesBlack Fireplace 1715 Illustrated Parts BreakdownDescription Part Number20-1 CGD3924PT CGD3930PT100639-01 100563-01101054-01 100565-01Page Page Industrial Ddve Box Bowling Green, KY Keep this WarrantyDate Purchased To you

CGD3924PT, CGD3930PT specifications

The Desa Tech CGD3924PT and CGD3930PT are sophisticated heating solutions designed to provide warmth and comfort in various residential settings. These models reflect the company's commitment to quality, efficiency, and user-friendliness, making them ideal for homeowners seeking reliable heat sources during colder months.

One of the standout features of both the CGD3924PT and CGD3930PT is their powerful heating capability. The CGD3924PT boasts an impressive heat output of 24,000 BTUs, while the CGD3930PT offers a robust 30,000 BTUs, ensuring they can effectively warm larger spaces quickly. This makes them suitable for living rooms, basements, and even commercial settings where efficient heating is crucial.

Both models are equipped with advanced infrared technology, which allows for more efficient heat distribution. This technology ensures that warmth is evenly dispersed throughout the room, minimizing cold spots and enhancing comfort. Additionally, the infrared heating process is known for being energy-efficient, translating to lower energy bills for the homeowner.

User convenience is another focus of the Desa Tech CGD series. Each unit is designed with an easy-to-use control panel that allows for simple adjustment of the temperature settings. This intuitive interface, combined with features like a remote control on the CGD3930PT, offers users the ability to manage their heating preferences effortlessly from anywhere in the room.

Safety is paramount, and Desa Tech takes it seriously. Both models feature an automatic shut-off mechanism that activates under specific conditions, providing peace of mind to users, especially in households with children or pets. In addition, the units incorporate a built-in oxygen depletion sensor, which ensures that the unit operates safely in enclosed spaces by shutting off if oxygen levels drop too low.

The aesthetic design of the CGD3924PT and CGD3930PT is another noteworthy characteristic. Both models feature a sleek, modern finish that can complement a variety of interior decor styles. They can be easily integrated into existing home designs without compromising overall aesthetics.

In summary, the Desa Tech CGD3924PT and CGD3930PT are powerful, efficient, and user-friendly heating solutions. With their advanced infrared technology, considerable heat outputs, straightforward controls, safety features, and attractive designs, they stand out as excellent choices for anyone looking to improve their home heating experience. Whether you’re seeking to warm up a cozy living space or a larger commercial area, these units deliver performance and reliability, making them worthy investments for any homeowner.