Desa Tech CGD3924PT, CGD3930PT installation manual Lighting Instructions

Page 22

OPERATING HEATER

Continued

OPERATING HEATER

Thermostatically-

Controlled Models

MANUAL LIGHTING PROCEDURE

1.Follow steps 1 through $ under Lighting Instructions, pages 20 and 21.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 on page 21.

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING

if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot_ follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

WARNING

If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE

During Initial operation of new heater, burning logs will give off a paper- burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

Note: Homeowners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However there may be times you will desire the full flames of the Hi heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat. WARNING: Damper handle will be hot if heater has been running.

Image 22
Contents Owners Operation and Installation Manual Patent PendingSafety Information SectionI004 Shut off gas supplyLocal Codes Safety PilotProduct Crossover Log Front Log Ignitor Contr¢AIR for Combustion Ventilation Unusually Tight ConstructionDetermining AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR AIR for CombustionVentilation Air From Inside Building Installing Check GAS TypeLOG Sizing Requirements Minimum Fireplace Clearance To Combustible MaterialsLog Size Side Wall Ceiling 18,24,30 Log Minimum Firebox Size Height Depth Front Width 14 =Minimum Non-Combustible Material Clearances If Not Using MantelHeat Resistant Material Mantel Clearances Minimum Non-Combustible Material Clearances If Using MantelRequirements for Safe Installation Non-Combustible Material Distance a Or moreCombustible Material Determining Minimum Mantel Clearance When Using a HoodFloor Clearances MinMasonry Fireplace Manufactured Fireplace Installing Damper Clamp Accessory for Vented OperationIll Installation Items Needed Installing Installing Heater Base AssemblyRegulator See Installation Items NeededExternal Piping check local codesReou,ator PropaneGas Meter C*** to Gas Hose Checking GAS ConnectionsFrom MinimumShutoff Valve Sed Pressure Testing Heater Gas ConnectionsTest Pressures Equal To or Less Than 1/2 Psig To..-=Slot Installing Logs%,% Cutut Front Log #3 NotchesIgnitorButlon \ Operating HeaterKnob Shutting Off Heater OperatingDo not operate heater between Pilot and High positions Press Turn Control knob clockwise To the HighLighting Instructions Operating Heater IgnitorElectrode ThermocoupleThermostat-Controlled Models Only Inspecting BurnersTurn control knob clockwise To the Pilot position Pilot Flame PAIrERNCleaning Maintenance TROUBLE- ShootingPane Observed ProblemPossible Cause CompanyShooting Observed Possible Problem CauseTrouble RemedyGas odor even when control knob is in OFF Observed Problem Possible CauseremedyGas leak. See Warning statement at top Sensing Bulb MountingThermostatScrew Retaining Claml Sensing Bulb ThermostatL Glass DoorsWhen gas quality is bad SpecificationsWhen gas pressure is too low Pilot will not stay lit Model Models Btu VariableParts Not Under Warranty Replacement Parts CentralParts Under Warranty FBDBlack Fireplace AccessoriesHood GA6050 Illustrated Parts Breakdown 1715Part Number DescriptionCGD3924PT CGD3930PT 20-1100565-01 100563-01101054-01 100639-01Page Page To you Keep this WarrantyDate Purchased Industrial Ddve Box Bowling Green, KY

CGD3924PT, CGD3930PT specifications

The Desa Tech CGD3924PT and CGD3930PT are sophisticated heating solutions designed to provide warmth and comfort in various residential settings. These models reflect the company's commitment to quality, efficiency, and user-friendliness, making them ideal for homeowners seeking reliable heat sources during colder months.

One of the standout features of both the CGD3924PT and CGD3930PT is their powerful heating capability. The CGD3924PT boasts an impressive heat output of 24,000 BTUs, while the CGD3930PT offers a robust 30,000 BTUs, ensuring they can effectively warm larger spaces quickly. This makes them suitable for living rooms, basements, and even commercial settings where efficient heating is crucial.

Both models are equipped with advanced infrared technology, which allows for more efficient heat distribution. This technology ensures that warmth is evenly dispersed throughout the room, minimizing cold spots and enhancing comfort. Additionally, the infrared heating process is known for being energy-efficient, translating to lower energy bills for the homeowner.

User convenience is another focus of the Desa Tech CGD series. Each unit is designed with an easy-to-use control panel that allows for simple adjustment of the temperature settings. This intuitive interface, combined with features like a remote control on the CGD3930PT, offers users the ability to manage their heating preferences effortlessly from anywhere in the room.

Safety is paramount, and Desa Tech takes it seriously. Both models feature an automatic shut-off mechanism that activates under specific conditions, providing peace of mind to users, especially in households with children or pets. In addition, the units incorporate a built-in oxygen depletion sensor, which ensures that the unit operates safely in enclosed spaces by shutting off if oxygen levels drop too low.

The aesthetic design of the CGD3924PT and CGD3930PT is another noteworthy characteristic. Both models feature a sleek, modern finish that can complement a variety of interior decor styles. They can be easily integrated into existing home designs without compromising overall aesthetics.

In summary, the Desa Tech CGD3924PT and CGD3930PT are powerful, efficient, and user-friendly heating solutions. With their advanced infrared technology, considerable heat outputs, straightforward controls, safety features, and attractive designs, they stand out as excellent choices for anyone looking to improve their home heating experience. Whether you’re seeking to warm up a cozy living space or a larger commercial area, these units deliver performance and reliability, making them worthy investments for any homeowner.