Desa Tech CGD3924PT Product, Local Codes, Crossover Log Front Log Ignitor Contr¢, Operation

Page 4

PRODUCT

IDENTIFICATION

LOCAL CODES

UNPACKING

PRODUCT

FEATURES

Crossover Log

Log.

Front Log

Ignitor

Contr¢

Figure 1 - Vent-Free Gas Log Heater

Install and use heater with care. Follow all local codes. In the absence of local

codes, use the latest edition of The National Fuel Gas Code ANSI Z223, also known as NFPA 54*.

*Available from:

Ameriean National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note: Where listed vented decorative logs are required, thermostat operation is not permitted.

1.Remove logs and heater base assembly from carton. Note: Do not pick up heater base assembly by burners. This could damage heater. Always handle base assembly by grate.

2.Remove all protective packaging applied to logs and heater for shipment.

3.Check all items for any shipping damage. If damaged, promptly inform dealer where you bought heater.

Operation

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic dancing, yellow flames. This heater is designed for vent-free operation with flue damper closed. State and local codes in some areas prohibit the use of vent-free heaters. You can operate heater as a vented product by opening flue damper.

Safety Pilot

This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts 9ff the heater if there is not enough fresh air.

Piezo Ignition System

This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

70a_4

Image 4
Contents Owners Operation and Installation Manual Patent PendingSafety Information SectionI004 Shut off gas supplySafety Pilot ProductLocal Codes Crossover Log Front Log Ignitor Contr¢AIR for Combustion Ventilation Unusually Tight ConstructionDetermining AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR AIR for CombustionVentilation Air From Inside Building Installing Check GAS TypeMinimum Fireplace Clearance To Combustible Materials Log Size Side Wall Ceiling 18,24,30LOG Sizing Requirements Log Minimum Firebox Size Height Depth Front Width 14 =Minimum Non-Combustible Material Clearances If Not Using MantelHeat Resistant Material Minimum Non-Combustible Material Clearances If Using Mantel Requirements for Safe InstallationMantel Clearances Non-Combustible Material Distance a Or moreDetermining Minimum Mantel Clearance When Using a Hood Floor ClearancesCombustible Material MinMasonry Fireplace Manufactured Fireplace Installing Damper Clamp Accessory for Vented OperationIll Installation Items Needed Installing Installing Heater Base AssemblyRegulator Installation Items Needed ExternalSee Piping check local codesReou,ator PropaneChecking GAS Connections FromGas Meter C*** to Gas Hose MinimumPressure Testing Heater Gas Connections Test Pressures Equal To or Less Than 1/2 PsigShutoff Valve Sed To..-=Installing Logs %,% CututSlot Front Log #3 NotchesIgnitorButlon \ Operating HeaterKnob Operating Do not operate heater between Pilot and High positionsShutting Off Heater Press Turn Control knob clockwise To the HighLighting Instructions Operating Heater IgnitorElectrode ThermocoupleInspecting Burners Turn control knob clockwise To the Pilot positionThermostat-Controlled Models Only Pilot Flame PAIrERNCleaning Maintenance TROUBLE- ShootingObserved Problem Possible CausePane CompanyObserved Possible Problem Cause TroubleShooting RemedyGas odor even when control knob is in OFF Observed Problem Possible CauseremedyGas leak. See Warning statement at top Sensing Bulb MountingThermostatScrew Retaining Claml Sensing Bulb ThermostatL Glass DoorsSpecifications When gas pressure is too low Pilot will not stay litWhen gas quality is bad Model Models Btu VariableReplacement Parts Central Parts Under WarrantyParts Not Under Warranty FBDBlack Fireplace AccessoriesHood GA6050 Illustrated Parts Breakdown 1715Part Number DescriptionCGD3924PT CGD3930PT 20-1100563-01 101054-01100565-01 100639-01Page Page Keep this Warranty Date PurchasedTo you Industrial Ddve Box Bowling Green, KY

CGD3924PT, CGD3930PT specifications

The Desa Tech CGD3924PT and CGD3930PT are sophisticated heating solutions designed to provide warmth and comfort in various residential settings. These models reflect the company's commitment to quality, efficiency, and user-friendliness, making them ideal for homeowners seeking reliable heat sources during colder months.

One of the standout features of both the CGD3924PT and CGD3930PT is their powerful heating capability. The CGD3924PT boasts an impressive heat output of 24,000 BTUs, while the CGD3930PT offers a robust 30,000 BTUs, ensuring they can effectively warm larger spaces quickly. This makes them suitable for living rooms, basements, and even commercial settings where efficient heating is crucial.

Both models are equipped with advanced infrared technology, which allows for more efficient heat distribution. This technology ensures that warmth is evenly dispersed throughout the room, minimizing cold spots and enhancing comfort. Additionally, the infrared heating process is known for being energy-efficient, translating to lower energy bills for the homeowner.

User convenience is another focus of the Desa Tech CGD series. Each unit is designed with an easy-to-use control panel that allows for simple adjustment of the temperature settings. This intuitive interface, combined with features like a remote control on the CGD3930PT, offers users the ability to manage their heating preferences effortlessly from anywhere in the room.

Safety is paramount, and Desa Tech takes it seriously. Both models feature an automatic shut-off mechanism that activates under specific conditions, providing peace of mind to users, especially in households with children or pets. In addition, the units incorporate a built-in oxygen depletion sensor, which ensures that the unit operates safely in enclosed spaces by shutting off if oxygen levels drop too low.

The aesthetic design of the CGD3924PT and CGD3930PT is another noteworthy characteristic. Both models feature a sleek, modern finish that can complement a variety of interior decor styles. They can be easily integrated into existing home designs without compromising overall aesthetics.

In summary, the Desa Tech CGD3924PT and CGD3930PT are powerful, efficient, and user-friendly heating solutions. With their advanced infrared technology, considerable heat outputs, straightforward controls, safety features, and attractive designs, they stand out as excellent choices for anyone looking to improve their home heating experience. Whether you’re seeking to warm up a cozy living space or a larger commercial area, these units deliver performance and reliability, making them worthy investments for any homeowner.