Empire Comfort Systems VFP36FP, VFP32FP, 31)L(N, P)-1, 21)L(N installation instructions Introduction

Page 5

INTRODUCTION

Instructions to Installer

1.Installer must leave instruction manual with owner after installation.

2.Installer must have owner fill out and mail warranty card supplied with unvented room heater.

3.Installer should show owner how to start and operate unvented room heater.

Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of an unvented room heater.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

WARNING: ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE DANGEROUS.

Improper installation or use of the heater can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning.

This series is design certified in accordance with American National Standard Z21.11.2 by the Canadian StandardsAssociation Laboratories as an Unvented Room Heater and should be installed according to these instructions.

Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change.

VFP(32,36)FP(30,31)L Only 750 Millivolt System

When you ignite the pilot, the thermocouple produces millivolts (electrical current) which energizes the magnet in the gas valve. After 30 seconds to 1 minute time period you can release the gas control knob and the pilot will stay ON. Allow your pilot flame to operate an additional one (1) to two (2) minutes before you turn the gas control knob from the PILOT position to the ON position. This time period allows the millivolts (electrical energy) to build-up to a sufficient level allowing the gas control to operate properly.

Important

All correspondence should refer to complete Model Number, Serial Number and type of gas.

Attention: During initial use of ceramic log you will detect an odor as the ceramic log is cured. Also, during the curing process the ceramic log will burn with a yellow flame.

Notice: During initial firing of this unit, its paint will bake out,

and smoke will occur. To prevent triggering of smoke alarms, ventilate the room in which the unit is installed.

Installation on Rugs and Tile

If this appliance is installed directly on carpeting, tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.

The base referred to above does not mean the fire-proof base as used on wood stoves. The protection is for rugs that are extremely thick and light colored tile.

Solid-fuels shall not be burned in a masonry or UL 127 factory- built fireplace in which an unvented room heater is installed.

Qualified Installing Agency

Installationandreplacementofgaspiping,gasutilizationequipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term "qualified agency" means any individual, firm, corporation or company which either in person or through a representative is engaged in and is responsible for (a) the installation or replacement of gas piping or (b) the connection, installation, repair or servicing of equipment, who is experienced in such work, familiar with all precautions required and has complied with all the requirements of the authority having jurisdiction.

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1.*

*Available from the American National Standards Institute, Inc. 1430 Broadway, New York, N.Y. 10018.

High Altitudes

For altitudes/elevations above 2,000 feet (610m), ratings should be reduced at the rate of 4 percent for each 1,000 feet (305m) above sea level. Contact the manufacturer or your gas company before changing spud/orifice size.

Well Head Gas Installations

Some natural gas utilities use "well head" gas. This may affect the Btu output of the unit. Contact the gas company for the heating value. Contact the manufacturer or your gas company before changing spud/orifice size.

WARNING: This appliance is equipped for (natural gas or propane) gas. Field conversion is not permitted.

20101-0-0306

Page 5

Image 5
Contents Installation Instructions Table of Contents Important Safety Information LP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction Minimum Firebox Opening SpecificationsModel Unusually tight construction is defined as construction where Unusually Tight ConstructionOutdoors Ventilation Air From Inside BuildingVentilation Air Ventilation Air From Inside Building Figure Ventilation Air From Outdoors FigureGAS Supply Installing a New Main Gas CockChecking Manifold Pressure ClearancesVFP32,36FP30,31 Millivolt Control Minimum Wall and Ceiling Clearances FigureCombustible Materials Fireplace Dimensions Finishing Installing Hood and Trim KITPlanning Installation Fireplace Framing and Installation Placing Lava Rock in Front of Burner on Fireplace Floor Placement of Glowing Embers and Lava RockOperation INSTRUCTIONS/FLAME Appearance VFP32,36FP30,31 Lighting Instructions For Your Safety Read Before LightingVFP32,36FP20,21 Lighting Instructions For Your Safety Read Before LightingPilot Flame Characteristics Maintenance WiringCheck 750 Millivolt System Operation Remote ReceiverHeater produces a whistling noise when main burner is lit Gas odor even when control knob is in OFF positionAppliance produces unwanted odors Appliance shuts off during use. Pilot stays onWire Assembly Parts ListParts View HOW to Order Repair PartsFBB4 Blower Installation Optional Variable Speed Blower Installation InstructionsBlower Wheels WiringBlower Motor Optional Brick Liner Installation Instructions Junction BOX Wiring Installation InstructionsService Notes

VFP32FP, VFP36FP, P)-1, 31)L(N, 21)L(N specifications

Empire Comfort Systems is a well-recognized name in the heating and appliance industry, known for its quality products and innovative technologies. Among their impressive offerings are the VFP32FP, VFP36FP, and VFP21)L(N,31)L(N,P)-1 series gas fireplaces, designed to provide warmth, ambiance, and efficiency for modern homes.

The VFP32FP is a versatile unit that seamlessly blends into various room designs. With a 32-inch viewing area, it showcases a beautiful flame while offering an impressive heat output. This model features a heat exchanger that ensures maximum warmth reaches the living space without excessive energy use. The VFP32FP also comes equipped with a millivolt system that allows for easy operation, even during power outages.

The VFP36FP is ideal for those seeking a larger fireplace experience. With a 36-inch viewing area, it not only enhances the aesthetic of any space but also produces substantial heat to combat chilly nights. What sets the VFP36FP apart is its high-efficiency design, ensuring lower emissions and reduced gas consumption. The unit's adjustable flame and thermostat controls allow homeowners to customize their heating needs easily.

Empire's VFP21)L(N,31)L(N,P)-1 offers a compact yet powerful heating solution. This fireplace is perfect for smaller spaces without sacrificing performance. It comes with a robust design and various decorative options to match any interior style. The advanced technology utilized in this model ensures efficient heat distribution, making it a practical choice for cozy living areas.

All models boast a range of features that enhance usability and comfort. They come with convenient remote control options, allowing for easy operation from anywhere in the room. The emphasis on safety is evident through the inclusion of glass safety screens and built-in safety shut-off systems.

Empire Comfort Systems has committed to sustainability, and these fireplaces exemplify that dedication. Each model is engineered to provide eco-friendly heating solutions, contributing to reduced carbon footprints while delivering exceptional performance.

In summary, the Empire Comfort Systems VFP series, including the VFP32FP, VFP36FP, and VFP21)L(N,31)L(N,P)-1, represents the perfect blend of innovation, efficiency, and beauty. With robust features and cutting-edge technology, these gas fireplaces fulfill the heating needs of contemporary homes while enhancing their visual appeal. Homeowners can enjoy warmth, style, and peace of mind knowing they have chosen a reliable and efficient product from Empire Comfort Systems.