Enviro EG 28 owner manual Horizontal Installation

Page 7

When planning your installation, it will be necessary to select the proper length of vent pipe for your particular requirements. It is important to note when passing through a wall, the maximum allowable wall thickness is 10-inches (254mm), 1 ½ inches clearance to combustibles must be maintained. Select the amount of vertical rise desired for “vertical-to-horizontal” type installations. To determine the length of vent pipe required for vertical installations, measure the distance from the appliance flue outlet to the ceiling, the ceiling thickness, the vertical rise through the attic or second story, and allow for sufficient vent height above the roofline. For two story applications, A firestop is required at each floor level. If an offset is needed in the attic, additional pipe and elbows will be required. To connect the venting system to the appliance flue outlet, a twist-lock adapter is built into the appliance at the factory.

HORIZONTAL INSTALLATION

STEP 1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the appliance.

STEP 2. Direct vent pipe and fittings are designed with special twist-lock connections. Assemble the desired combination of black pipe and elbows to the appliance adapter with pipe seams oriented towards the wall or floor, as much out of view as possible.

Place a bead of Mil-Pac on the outer edge of the inner exhaust pipe (non-flared end). Place a bead of high temperature silicone on the male edge of the outer pipe. Push the pipe sections completely together, then twist-lock one section clockwise approximately one-quarter turn, until the two sections are fully locked. The female locking lugs will not be visible from the outside, on black pipe. They may be located by examining the inside of the female ends as shown in FIG-10.

NOTE:

(1)Twist-lock procedure: four indentations, located on the female end of the pipes and fittings, are designed to slide straight onto the male ends of adjacent pipes and fittings, by orienting the four pipe indentations so they match and slide into the four entry slots on the male end.

(2)Horizontal runs of vent pipe must be supported every three feet. Wall straps are available for this purpose.

FIG. 10

FIG.10

STEP 3. With the pipe attached to the stove into the correct location, mark the wall for a 10 inch x 10 inch square hole. The center of the square hole should match the centerline of the horizontal pipe. Cut and frame the 10-inch x 10-inch hole in the exterior wall where the vent will be terminated. If the wall being penetrated is constructed of non- combustible material i.e. masonry or concrete, a 7-inch hole is acceptable.

STEP 4. Position the horizontal vent termination in the center of the 10-inch square hole, and attach to the exterior wall with the four screws provided. Before attaching the Vent Termination to the exterior wall, run a bead of non-hardening mastic around the edges, so as to make a seal between the termination and the wall. The arrow on the vent termination should be pointing up, insure that the proper clearances to combustible materials are maintained.

STEP 5. Before connecting the horizontal run of the vent pipe to the vent termination, slide the black decorative wall thimble cover over the vent pipe.

STEP 6. Slide the appliance and vent assembly towards the wall, carefully inserting the vent pipe into the cap assembly. It is important that the vent pipe extend into the vent cap a sufficient distance with a minimum of 1 ¼inch overlap. Secure the connection between the vent cap pipe and the vent cap by attaching the two sheet metal straps extending from the vent cap assembly into the outer wall of the vent pipe. Use the two sheet metal screws provided to connect the straps to the vent pipe. Bend any remaining portion of the sheet metal straps back towards the vent cap, so the decorative wall thimble FIG-13 will conceal it.

7

Image 7
Contents What to do if YOU Smell GAS For Your SafetyFor Your Safety Safety PrecautionsAssembly Instructions Table of ContentsCode Approvals Dimensions Deciding Where to Locate Your StoveClearances Vent Terminal Clearances Simpson Duravent Parts Planning Your InstallationHorizontal Installation FIG-13 FIG-14 Vertical Installation FIG-21FIG-22 Cathedral Ceiling Installation Spring Spacers Mobile Home Venting Into Class a ChimneysInstalling the Glowing Embers Installation of Logset and EmbersLighting Instructions Operating InstructionsFor Cleaning the Inside of the Firebox Maintenance and TechnicalCleaning of Glass To Replace Door and Glass AssemblyProblem Possible Cause Solution Trouble ShootingNatural GAS Propane GAS Never USE AN Open Flame for Leak Testing ElectricalGAS Line Connection Orifice SIZES, Pressure and BTU’SInstalling Remote Thermostat or Wall Switch Installing or Removing the Blower Parts and AccessoriesFuel Conversion Adjusting the VenturiTo a Maximum of Seven Years WarrantyParts List Exploded EG28 FreestandingEC-059 Strip Model EG 28 Direct Vent Installation Data Sheet

EG 28 specifications

The Enviro EG 28 is an innovative environmental solution designed for efficient waste management and recycling. This versatile equipment is engineered to handle a variety of materials, making it an essential tool for waste processing facilities, recycling centers, and industrial applications. Its robust design and advanced technologies ensure optimal performance and reliability.

One of the main features of the Enviro EG 28 is its high-capacity processing capability. The system is capable of handling large volumes of waste, which increases operational efficiency and reduces the frequency of emptying and maintenance. This is particularly beneficial in high-demand environments where downtime must be minimized. The Enviro EG 28 also incorporates advanced sorting technology that allows it to differentiate between various materials, optimizing the recycling process and improving the quality of the end products.

The Enviro EG 28 utilizes cutting-edge sensors and artificial intelligence to enhance its operation. These smart technologies enable the system to automatically adjust to different types and sizes of waste materials, ensuring efficient sorting and processing. This adaptability is crucial in today’s ever-changing waste landscape, where contamination and mixed materials can pose significant challenges.

Another significant characteristic of the Enviro EG 28 is its eco-friendly design. It operates with reduced energy consumption compared to traditional waste management systems, reflecting a commitment to sustainability. The efficient use of energy not only lowers operational costs but also minimizes the environmental impact of waste processing activities.

Durability is a key attribute of the Enviro EG 28. Constructed from high-quality materials, it withstands the rigors of a demanding work environment. Its maintenance is straightforward, ensuring that organizations can keep operational disruptions to a minimum.

In summary, the Enviro EG 28 stands out in the waste management sector due to its high capacity, advanced sorting technology, smart sensors, energy efficiency, and durable construction. It represents a significant advancement toward more sustainable waste management practices, making it a valuable asset for any organization committed to environmental responsibility and operational excellence. As waste management continues to evolve, the Enviro EG 28 is poised to play a pivotal role in shaping the future of recycling and waste processing efficiency.