Enviro 50-029 owner manual Are Permitted to Reach the Outside Vent Termination

Page 11

Initial Installation

VENT PARTS:

Table 2: Vent part numbers.

Simpson Duravent (SD), Selkirk (SEL), and Security Chimneys (SC), must state if galvanized or black wanted, PART NUMBERS:

SD

SEL

SC

Description

SD

SEL

SC

Description

 

 

 

 

 

 

 

 

908

4DT-6

SV4L6

6” pipe length

911

 

 

11” to 14 5/8” pipe, adjustable

907

4DT-9

 

9” pipe length

 

4DT-AJ

 

4” to 10” pipe , adjustable

 

 

 

 

 

 

 

 

906

4DT-12

SV4L12

12” pipe length

 

 

SV4LA12

11⁄2” to 12” pipe , adjustable

 

 

 

 

 

 

 

 

904

4DT-24

SV4L24

24” pipe length

943

4DT-AF6

 

Flashing, 0/12 to 6/12 roof pitch

 

 

 

 

 

 

 

 

903

4DT-36

SV4L36

36” pipe length

943S

4DT-AF12

 

Flashing, 7/12 to 12/12 roof pitch

 

 

 

 

 

 

 

 

902

4DT-48

SV4L48

48” pipe length

 

 

SV4FA

Flashing, 1/12 to 7/12 roof pitch

 

 

 

 

 

 

 

 

945

4DT-EL45

SV4EBR45

45° elbow, black

 

 

SV4FB

Flashing, 8/12 to 12/12 roof pitch

 

 

 

 

 

 

 

 

990

4DT-EL90

SV4EBR90

90° elbow, black

943F

 

SV4F

Flat flashing

 

 

 

 

 

 

 

 

950

4DT-VS

SV4VS

Vinyl siding standoff/sheild

980

4DT-VC

SV4CGV

Vertical termination

 

 

 

 

 

 

 

 

942

4DT-WT

SV4RSN

Wall thimble

991

4DT-HVC

 

High wind vertical termination

 

 

 

 

 

 

 

 

941

4DT-CSS

SV4CSB

Cathedral Support Box

984

4DT-HC

SV4CHC

Horizontal square termination

 

 

 

 

 

 

 

 

981

4DT-ST36

SV4STC36

36” Snorkel Termination

985

4DT-HHC

 

High wind horizontal termination

 

 

 

 

 

 

 

 

953

4DT-SC

SV4FC

Storm collar

978

4DT-VKC

SV0FAK

Vertical termination kit

 

 

 

 

 

 

 

 

963

4DT-FS

SV4BF

Fire stop

970

4DT-HKA

SV0SHK

Horizontal termination kit

 

 

 

 

 

 

 

SD: Basic Kit, SEL: Kit A, SC: Standard Kit

988

4DT-WS/B

SV4BM

Wall strap/support/band

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

971

4DT-HKB

SV0SHK2

Horizontal termination kit

 

 

 

 

 

 

 

SD: Kit A, SEL: Kit B, SC: Kit

 

 

 

 

 

 

 

 

This fireplace have been tested and certified for use with SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES. SELKIRK DIRECT-TEMP SYSTEM SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “METALBESTOS MDV VENT SYSTEM” kits are available for horizontal venting. When using Simpson Duravent, it is recommended that, before installation, a bead of RTV High Temperature Silicone should be applied to each outer vent joint, and Mil-Pac to each inner joint. When planning an installation, it will be necessary to select the proper length of vent pipe for the particular requirements.

When planning your installation, it will be necessary to select the proper length of vent pipe for your particular requirements. It is important to note when passing through a wall, the maximum allowable wall thickness is 10 inches (254 mm), 11⁄2” inches clearance to combustibles must be maintained.

A MINIMUM VERTICAL LENGTH OF 24” (610 mm) TO THE FIRST 90° ELBOW IS REQUIRED. WITH THIS MINIMUM VERTICAL RISE, HORIZONTAL RUNS OF FROM 1 FT (305 mm) to 3 FT (915 mm)

ARE PERMITTED TO REACH THE OUTSIDE VENT TERMINATION.

BEFORE BEGINNING THE INSTALLATION TAKE CARE TO ENSURE AN APPROPRIATE OUTSIDE LOCATION FOR THE VENT TERMINATION CAN BE ACCOMMODATED. FOLLOW THE VENT LENGTH DIAGRAM

PRECISELY.

VENTING TERMINALS CANNOT BE RECESSED INTO A WALL OR SIDING.

If extra elbows are being used, overall allowable length will be reduced by 3 ft (915 mm) per additional elbow.

11

Image 11
Contents What to do if YOU Smell GAS General Safety PrecautionsTable of Contents This Enviro Ascot Fireplace Codes And ApprovalsVented GAS Fireplace Heater Ascot DV NG/LPG Dimensions of the Ascot SpecificationsOperating Instructions For Your Safety Read Completely Before OperatingMaintenance And Service Removing inner glass door To ReplaceTo be Installed by a Qualified Service Agency only Qualified Installers only Initial InstallationAre Permitted to Reach the Outside Vent Termination Vent Restrictor Setting Round Support High temperature silicone on Installing Vent Cap with Vinyl Siding Stand-Off Straight Through Wall Installation Vertical Installation Material overlaps the top edge of the flashing Step InstallationWiring Diagram Venting of a Fireplace Fitted with the Drafthood Adaptor Canadian InstallationsA. Installations General Venting InformationOptional Finishing Automatic Safety Shut DownSpill Switch Replacement Hearth Mount Installation To Test Valve Pressures GAS Line ConnectionControls Wiring Errors Can Cause Improper Ascot Burner Tray Secondary InstallationEmber Placement Problem Possible Cause Solution Trouble ShootingReference Description Part Number Parts ListCast Description Reference Cast Description Part Number Parts Diagram To the Distributor WarrantyInstallation Data Sheet

50-029 specifications

Enviro 50-029 is an innovative environmental monitoring device designed to provide comprehensive data collection and analysis for various ecological parameters. With its cutting-edge features, the device has garnered attention in industries such as agriculture, environmental science, and urban planning.

One of the cornerstone features of the Enviro 50-029 is its multi-sensor capability. This device is equipped with a suite of sensors that can measure a wide range of environmental variables. These include temperature, humidity, air quality, soil moisture, and light intensity. The integration of multiple sensors allows users to gather detailed insights into the ecosystem, enabling better decision-making and resource management.

The Enviro 50-029 also utilizes advanced wireless communication technologies, such as LoRaWAN and Zigbee. This allows for real-time data transmission without the need for extensive wiring or infrastructure. The device can connect to a central hub or cloud-based platform, facilitating remote monitoring and accessibility of data from anywhere in the world. This feature is particularly valuable for researchers and environmental agencies monitoring remote or hard-to-reach areas.

Power efficiency is another significant characteristic of the Enviro 50-029. Utilizing low-power design protocols, the device can operate for extended periods on minimal battery power. This sustainability aspect is crucial, particularly for long-term environmental monitoring projects where replacing batteries frequently can be logistically challenging.

Moreover, the Enviro 50-029 is built to withstand various environmental conditions. Its robust, weather-resistant casing ensures durability in extreme temperatures and harsh weather environments. This makes it suitable for outdoor deployments, whether in agricultural fields, forests, or urban areas, without compromising performance.

The device also supports customizable settings, enabling users to define specific thresholds and alerts for different environmental parameters. This feature allows for proactive monitoring and notifications on critical changes, providing essential data needed to respond to environmental concerns swiftly.

Overall, the Enviro 50-029 stands out as a versatile and reliable tool for environmental monitoring. Its multi-sensor capabilities, advanced communication technologies, power efficiency, and robust design make it an excellent choice for research, conservation efforts, and smart farming applications. By integrating such a sophisticated device into their operations, users can gain actionable insights and contribute to a more sustainable future.