Enviro 50-029 owner manual Straight Through Wall Installation

Page 16

Initial Installation

Interior

Exterior

Wall Surface

 

Wall Surface

2.5"

 

(64mm)

Horizontal

 

Inside

Vent Section

 

Finished

 

Collar

 

 

Horizontal

 

Vent

 

Termination

 

Wall

If installed on a

Thimble

 

carpeted surface

 

a hearth is required

Insulation

 

Figure 17: Straight Through Wall Installation.

NOTES:

(1)The horizontal run of vent pipe must be level and should have a 1⁄4 inch rise for every one foot of run towards the termination. Never allow the vent to run downward. This could cause high temperature and may present the possibility of a fire.

(2)The location of the horizontal vent termination on the exterior wall must not be easily blocked or obstructed. Refer to “Initial Installation - Vent Termination Restrictions” section.

(3)When installing a vent pipe in a chase the minimum clearance to combustibles is 2” (51 mm).

NOTE: Vent pipe must not be longer than 18” (457 mm) maximum when installing straight through exterior wall.

Maintain manufacturer’s clearances to combustibles with venting.

Vent may extend between 6 inches (152

mm)and 18 inches (457 mm) maximum straight out.

When installing this unit in a corner the maximum distance after 45˚ elbow is 9 inches (228 mm).

If between 9 inches (229 mm) and 24 inches (610 mm), a 14 inches (356 mm) snorkel must be used.

 

Horizontal

 

Vent

24" (610mm)

Termination

Maximum

 

Horizontal

 

Inside

 

Finished

 

Collar

 

24" (610mm)

Wall

Thimble

Minimum

 

Vertical

 

 

Exterior

 

Wall Surface

 

Insulation

Interior Wall

 

Surface

 

If installed on a

 

carpeted surface

 

a hearth is required

 

Figure 18: Up Then Through Wall Installation.

 

16

Image 16
Contents What to do if YOU Smell GAS Safety Precautions GeneralTable of Contents Vented GAS Fireplace Heater Ascot DV NG/LPG Codes And ApprovalsThis Enviro Ascot Fireplace Specifications Dimensions of the AscotFor Your Safety Read Completely Before Operating Operating InstructionsMaintenance And Service To Replace Removing inner glass doorTo be Installed by a Qualified Service Agency only Initial Installation Qualified Installers onlyAre Permitted to Reach the Outside Vent Termination Vent Restrictor Setting Round Support High temperature silicone on Installing Vent Cap with Vinyl Siding Stand-Off Straight Through Wall Installation Vertical Installation Material overlaps the top edge of the flashing Wiring Diagram InstallationStep Canadian Installations A. InstallationsGeneral Venting Information Venting of a Fireplace Fitted with the Drafthood AdaptorSpill Switch Replacement Automatic Safety Shut DownOptional Finishing Hearth Mount Installation GAS Line Connection To Test Valve PressuresControls Wiring Errors Can Cause Improper Secondary Installation Ascot Burner TrayEmber Placement Trouble Shooting Problem Possible Cause SolutionParts List Reference Description Part NumberCast Description Reference Cast Description Part Number Parts Diagram Warranty To the DistributorInstallation Data Sheet

50-029 specifications

Enviro 50-029 is an innovative environmental monitoring device designed to provide comprehensive data collection and analysis for various ecological parameters. With its cutting-edge features, the device has garnered attention in industries such as agriculture, environmental science, and urban planning.

One of the cornerstone features of the Enviro 50-029 is its multi-sensor capability. This device is equipped with a suite of sensors that can measure a wide range of environmental variables. These include temperature, humidity, air quality, soil moisture, and light intensity. The integration of multiple sensors allows users to gather detailed insights into the ecosystem, enabling better decision-making and resource management.

The Enviro 50-029 also utilizes advanced wireless communication technologies, such as LoRaWAN and Zigbee. This allows for real-time data transmission without the need for extensive wiring or infrastructure. The device can connect to a central hub or cloud-based platform, facilitating remote monitoring and accessibility of data from anywhere in the world. This feature is particularly valuable for researchers and environmental agencies monitoring remote or hard-to-reach areas.

Power efficiency is another significant characteristic of the Enviro 50-029. Utilizing low-power design protocols, the device can operate for extended periods on minimal battery power. This sustainability aspect is crucial, particularly for long-term environmental monitoring projects where replacing batteries frequently can be logistically challenging.

Moreover, the Enviro 50-029 is built to withstand various environmental conditions. Its robust, weather-resistant casing ensures durability in extreme temperatures and harsh weather environments. This makes it suitable for outdoor deployments, whether in agricultural fields, forests, or urban areas, without compromising performance.

The device also supports customizable settings, enabling users to define specific thresholds and alerts for different environmental parameters. This feature allows for proactive monitoring and notifications on critical changes, providing essential data needed to respond to environmental concerns swiftly.

Overall, the Enviro 50-029 stands out as a versatile and reliable tool for environmental monitoring. Its multi-sensor capabilities, advanced communication technologies, power efficiency, and robust design make it an excellent choice for research, conservation efforts, and smart farming applications. By integrating such a sophisticated device into their operations, users can gain actionable insights and contribute to a more sustainable future.