Breckwell P2000FS, P2000I owner manual AS a BUILT-IN Fireplace

Page 12

12

INSTALLATION

D.AS A BUILT-IN FIREPLACE

Figures 16 and 17 describe a P2000 installation vented into either a special chase built outside an outer wall or a false inside wall. This is especially suited for new construction or remodeling.

The equipment compartment (sides and rear of the stove in fireplace) must be enclosed per the applicable electrical standards.

NOTE: Floor protection for Built-in raised hearths requires a continuous sheet beneath to prevent the possibility of embers falling through to the combustible floor if cracks or separation should occur in the finished surface.

The chase dimensions shown are minimums and must be maintained.

FIGURE 16

FIGURE 17

Image 12
Contents Luxury Series P2000 Introduction Important InformationSafety Precautions Table of Contents Installation When Outside AIR is not Used Combustion AIR SupplyVenting Rear View P2000FS Rear View P2000IFreestanding Installation Equivalent Vent Length EVLHorizontally Through Wall Vertically with NEW Chimney System Refer to Figure Vertically Into Existing Chimney SystemInstallation Through Side of Masonry Chimney Vertically Into Existing Masonry FireplaceInsert Installations Assembling the Flashing SETWhen Vent Pipe Extends to Chimney TOP Refer to Figure Chase dimensions shown are minimums and must be maintained AS a BUILT-IN FireplaceElectrical Installation Special Mobile Home RequirementsOperation Proper Fuel PRE-START-UP CheckBuilding a Fire Hotrod Automatic FirestarterBreckwell Maintenance Tool Shutdown ProcedureSafety Features RE-STARTING a Warm StoveThermostat Installation Thermostat InstallationOptional Thermostat Millivolt Thermostat is RequiredPlease Read this Maintenance ASH RemovalASH Disposal Freestanding Models ASH Disposal InsertCleaning Vacuum USEBlowers Chimney Cleaning Recommended Maintenance ScheduleRemoval and Replacement of Broken Door Glass Daily Weekly Annually or per TonP2000I Troubleshooting Guide Stove Shuts OFF and the # 2 Light FlashesPossible Causes Stove Shuts OFF and the # 3 Light Flashes Stove Feeds PELLETS, but will not Ignite Possible Causes Possible RemediesSmoke Smell Coming Back Into the Home Convection Blower Shuts OFF and Comes Back onTroubleshooting Guide Troubleshooting Guide High Limit Switch Keeps Tripping Smoke Smell or Soot BUILD-UPDigital Circuit Board Timing Rates P2000Electrical Diagram Replacement Parts BurnpotLifetime Limited Warranty
Related manuals
Manual 31 pages 35.78 Kb Manual 30 pages 40.93 Kb