Breckwell P2000I, P2000FS owner manual Introduction, Important Information

Page 2

2

INTRODUCTION

Thank you for purchasing the Breckwell Pellet Burning Stove. You are now prepared to burn wood in the most efficient, convenient way possible. To achieve the safest, most efficient and most enjoyable performance from your stove, you must do three things: 1) Install it properly;

2)Operate it correctly; and 3) Maintain it regularly. The purpose of this manual is to help you do all three.

PLEASE read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury or even death.

Keep this manual handy for future reference.

Your Breckwell P2000 comes as a fireplace insert or as a freestanding stove with a pedestal.

This stove has been independently tested to ASTM E1509-95 Standard Specification for Room Heaters, Pellet Fuel Burning Type 1, UL 1482-1998 Standard for Solid Fuel Room Heaters, Oregon Administrative Rules for Mobile Homes (814-23-900 through 814-23-909) and Installation as a Stove Heater.

This pellet stove, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70.

This appliance is designed specifically for use only with pelletized wood. It is designed for residential installation according to current national and local building codes as a freestanding room heater. It is also approved as a mobile home heater which is designed for connection to an outside combustion air source.

The stove will not operate using natural draft or without a power source for the blower systems and fuel feed system and must not be burned with any type of coal (see PROPER FUEL).

This stove is designed to provide the optimum proportions of fuel and air to the fire in order to burn free of smoke and soot. Any blockage of the air supply to or from the stove will seriously degrade its performance and will be evidenced by a smoking exhaust and a sooting window. For best operation the ash content of the pellet fuel should be less than 1% and the calorific value approximately 8200 BTU/LB. Avoid high ash content fuels because this will rapidly fill up the burn pot and eventually cut off the combustion air supply.

Commercial and industrial installations of Breckwell Pellet Stoves should not be used since operational control is often not well managed in these settings.

IMPORTANT INFORMATION

Model: _____P2000 ________________

Style: ____________________________

Serial Number:_____________________

Purchase Date: ____________________

Purchased From:___________________

___________________

___________________

MAIL YOUR WARRANTY CARD TODAY To receive full warranty coverage, you will need to show evidence of the date you purchased your stove. We suggest that you attach your sales invoice to this page, and fill in the form on the left, so that you will have all the information you need in one place should the need for service or information occur.

Image 2
Contents Luxury Series P2000 Introduction Important InformationSafety Precautions Table of Contents Installation Venting When Outside AIR is not UsedCombustion AIR Supply Rear View P2000FS Rear View P2000IHorizontally Through Wall Freestanding InstallationEquivalent Vent Length EVL Vertically with NEW Chimney System Refer to Figure Vertically Into Existing Chimney SystemInstallation Through Side of Masonry Chimney Vertically Into Existing Masonry FireplaceInsert Installations Assembling the Flashing SETWhen Vent Pipe Extends to Chimney TOP Refer to Figure Chase dimensions shown are minimums and must be maintained AS a BUILT-IN FireplaceElectrical Installation Special Mobile Home RequirementsOperation Building a Fire Proper FuelPRE-START-UP Check Hotrod Automatic FirestarterSafety Features Breckwell Maintenance ToolShutdown Procedure RE-STARTING a Warm StoveOptional Thermostat Thermostat InstallationThermostat Installation Millivolt Thermostat is RequiredPlease Read this ASH Disposal Freestanding Models MaintenanceASH Removal ASH Disposal InsertBlowers CleaningVacuum USE Removal and Replacement of Broken Door Glass Chimney CleaningRecommended Maintenance Schedule Daily Weekly Annually or per TonP2000I Possible Causes Troubleshooting GuideStove Shuts OFF and the # 2 Light Flashes Stove Shuts OFF and the # 3 Light Flashes Smoke Smell Coming Back Into the Home Stove Feeds PELLETS, but will not IgnitePossible Causes Possible Remedies Convection Blower Shuts OFF and Comes Back onTroubleshooting Guide Troubleshooting Guide Digital Circuit Board Timing Rates High Limit Switch Keeps TrippingSmoke Smell or Soot BUILD-UP P2000Electrical Diagram Replacement Parts BurnpotLifetime Limited Warranty
Related manuals
Manual 31 pages 35.78 Kb Manual 30 pages 40.93 Kb