Lucent Technologies EST-48 FTF13 Offset Elevation Chart, Installing Offsets

Page 13

A2

C2

A1

C1

A2

C2

B2

A1

B1

C1

B2

B1

FTF13 OFFSET ELEVATION CHART

 

A

B

 

FTF13-ES30

 

Number of FTF13

A

B

Offset

Height

Offset/Return

FTF13-S4

Chimney Sections

Offset

Height

 

 

 

 

 

 

 

 

 

 

(Inches)

(Inches)

Elbow Set

Stabilizer

12"

18"

36"

(mm)

(mm)

 

 

 

 

 

 

 

 

 

 

 

 

4

 

15

³⁄₄

1

0

0

0

0

102

400

 

9

 

24

¹⁄₂

1

0

1

0

0

229

622

 

12

 

29

³⁄₄

1

0

0

1

0

305

756

 

14

¹⁄₄

33

¹⁄₂

1

0

2

0

0

362

851

 

17

¹⁄₄

38

¹⁄₂

1

0

1

1

0

438

978

 

20

¹⁄₄

43

³⁄₄

1

0

0

2

0

514

1111

 

21

 

45

¹⁄₄

1

0

0

0

1

533

1149

 

22

¹⁄₄

47

¹⁄₂

1

0

2

1

0

565

1207

 

25

¹⁄₄

52

¹⁄₂

1

0

1

2

0

641

1334

 

26

¹⁄₄

54

¹⁄₄

1

0

1

0

1

667

1378

 

28

¹⁄₄

57

³⁄₄

1

0

0

3

0

718

1467

 

29

¹⁄₄

59

¹⁄₄

1

0

0

1

1

743

1505

 

31

¹⁄₄

63

 

1

0

2

0

1

794

1600

 

32

¹⁄₂

65

 

1

0

4

1

0

826

1651

 

34

¹⁄₄

68

¹⁄₄

1

0

1

1

1

870

1734

 

36

¹⁄₄

71

³⁄₄

1

0

3

0

1

921

1822

 

37

¹⁄₄

73

¹⁄₄

1

0

0

2

1

946

1861

 

38

¹⁄₄

75

 

1

0

0

0

2

972

1905

 

39

¹⁄₄

77

 

1

0

2

1

1

997

1956

 

41

¹⁄₂

80

¹⁄₂

1

0

1

4

0

1054

2045

 

43

¹⁄₄

83

³⁄₄

1

0

1

0

2

1099

2127

 

44

¹⁄₂

85

³⁄₄

1

0

3

1

1

1130

2178

 

45

¹⁄₄

87

¹⁄₂

1

0

0

3

1

1149

2223

 

46

¹⁄₄

89

 

1

0

0

1

2

1175

2261

 

48

¹⁄₄

91

¹⁄₂

1

0

2

0

2

1226

2324

 

49

¹⁄₂

94

¹⁄₂

1

0

1

5

0

1257

2400

 

51

¹⁄₄

97

³⁄₄

1

0

1

1

2

1302

2483

 

54

¹⁄₄

103

 

1

0

0

2

2

1378

2616

 

55

¹⁄₄

104

¹⁄₂

1

0

0

0

3

1403

2654

 

56

¹⁄₂

106

¹⁄₂

1

0

2

1

2

1435

2705

 

59

¹⁄₂

111

³⁄₄

1

0

1

2

2

1511

2838

 

61

³⁄₄

116

 

1

1

1

0

3

1568

2946

 

64

³⁄₄

121

¹⁄₄

1

1

0

1

3

1645

3080

 

67

 

124

³⁄₄

1

1

2

0

3

1702

3169

 

69

 

127

³⁄₄

1

1

1

3

2

1753

3245

 

70

 

130

 

1

1

1

1

3

1778

3302

 

Figure 36

 

 

 

 

 

 

 

 

 

Joints

Chimney

 

 

 

 

 

4'

Required

At

6'

 

 

 

 

 

Past

Section

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screws

Joint

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Offset

Every

 

 

 

 

 

Required 6'

In

of

 

No. 8 x 1/2" SMS

 

6'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

First

 

 

 

 

 

 

 

 

Screws

For

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

Joints

 

 

 

 

 

 

 

 

 

Figure 37

73

 

135

¹⁄₄

1

1

0

2

3

1854

3435

75

 

138

³⁄₄

1

1

2

1

3

1905

3524

79

 

145

¹⁄₂

1

1

1

0

4

2007

3696

80

¹⁄₄

147

¹⁄₂

1

1

3

1

3

2038

3747

82

 

150

³⁄₄

1

1

0

1

4

2083

3829

87

 

159

¹⁄₂

1

1

1

1

4

2210

4051

INSTALLING OFFSETS

First, review the Offset Elevation Chart and see Figure 39 for reference.

Step 1. Determine the offset distance where chimney is to pass through the first ceiling- dimension “A.” To find this point on your ceil- ing, first determine the center point for a verti- cal chimney following the instructions for ver- tical installation.

Measure height to the ceiling from the top of fireplace-dimension “B.” Use the appropriate Offset Elevation Chart to find dimension “A.” Mark point where you will drive your nail to show the center point for your offset ceiling cut.

Step 2. Proceed by using the Straight Up Instal- lation Instructions for cutting and framing ceil- ing and roof openings.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

13

Image 13
Contents Wood Burning Fireplaces Retain These Instructions For Future Reference850,006M REV. C 04/2004 WH Report NoTable of Contents Precautions Typical InstallationIntroduction Clearances and Height RequirementsChimney Height Assembly OutlineChase Enclosure Location of FireplacePRE-INSTALLATION Notes Assembly StepsInstalling the Fireplace Combustible Wall HearthConsult all local codes Fireplace SpecificationsFront Left SideFraming Specifications 8d nails when completely installed Installing the Chimney SystemChimney 30 Offset Through Floor Or Ceiling Attic Above Firestop Spacer12 to 12/12 Roof Pitch Model Flat to 6/12Using a FTF13-CT2 Chase Termination Using a FTF13-CT1 Chase TerminationTEN Foot Rule Summary Special Offset Instructions Multiple TerminationsOffset Calculations Height FTF13 Vertical Elevation ChartChimney Only Installing Offsets FTF13 Offset Elevation ChartReturn Elbow Assembly Offset Elbow AssemblyCombustion Air Kits Cold Climate Insulation Optional Equipment ConsiderationsFireplace Finishes Methods of Determining Hearth Extension Equivalents Hearth Extensions and Wall ShieldsFinish to Your Taste Installation ComponentsSum of all R values is 70 + .10 + .068 + .5825 = Round Termination 63L44 Page West Taft Avenue Orange, CA 850,006M REV. C 04/2004

EST-48 specifications

Lucent Technologies EST-48 is a cutting-edge telecommunications platform designed to enhance voice and data connectivity for enterprises and service providers alike. As a versatile solution, the EST-48 combines robust functionalities with advanced technology to meet the growing demands of modern communication infrastructures.

One of the main features of the EST-48 is its seamless integration capabilities. It allows organizations to unify their voice, video, and data services over a single network, thereby simplifying management and reducing operational costs. This integration is crucial for businesses looking to streamline their communication systems and improve collaboration among employees.

The EST-48 utilizes a modular architecture, providing flexibility and scalability to accommodate varying organizational needs. This modularity enables businesses to start with a basic configuration and expand their systems as they grow, adding new capabilities and services without significant disruptions. This characteristic is particularly beneficial for rapidly evolving enterprises.

In terms of technology, the EST-48 is equipped with advanced switching and routing capabilities, ensuring efficient data transmission and reduced latency. Its support for Voice over Internet Protocol (VoIP) technology allows for high-quality voice communications over the internet, significantly improving the clarity and reliability of calls. Additionally, the platform supports a variety of communication standards, making it compatible with existing infrastructure and third-party equipment.

Another significant characteristic of the EST-48 is its emphasis on security. The platform incorporates various security measures to protect sensitive data and prevent unauthorized access. This includes features such as encryption, secure access controls, and regular software updates to safeguard against potential vulnerabilities.

Moreover, the EST-48 comes with robust management tools that provide real-time monitoring and reporting capabilities. These tools enable administrators to track system performance, identify issues, and optimize the network for better efficiency.

In conclusion, Lucent Technologies EST-48 stands out as a versatile communications platform that combines advanced technology with user-friendly features. Its integration capabilities, modular design, emphasis on security, and management tools make it an ideal choice for organizations seeking to improve their communication systems in a cost-effective manner. As communication technology continues to evolve, platforms like the EST-48 will remain essential in meeting the needs of modern enterprises and service providers.