Lucent Technologies EST-48 Chimney Height, Chase Enclosure, Location of Fireplace

Page 4

Insulate Joists

Same As Ceiling

19"

(483mm)

Draft Stops

F10FS-2

Firestop

FTF13-CT2

Termination

Note: Non- Combustible Chase Flashing must be Used to Cover Chase Opening

8'

(2.4m)

Level

Insulation

(Thermal Barrier)

19"

(483mm)

Optional

Insulation

in Outside

Walls of

Chase

Solid

Continuous

Surface

Outside Base

Note: Do not insulate the chase cavity with blown or fill type insulation materials.

Note: Local codes may not require firestopping at the ceiling levels for outside chase installa- tions. However, it is recommended for safety and the reduction of heat loss.

Chimney Height

The total height of your completed fireplace system from the surface the fireplace rests on to the chimney top must not exceed 80' and must also meet minimum height requirements. Refer to the minimum system height chart.

Minimum System Height

Security's FTF13 Pipe

Vertical Installation

15' 6"

 

 

One Offset

18' 0"

 

 

Two Offsets

20' 0"

 

 

Chase Enclosure

A chase is a vertical box-like structure con- structed to surround the fireplace and chimney. Refer to Figure 2 for a typical chase configura- tion. As with all chimney installations, avoid overhead obstructions such as trees, power lines, etc. A chase should be constructed and insulated just like any outside wall. In a cold climate, we recommend the base of the chase should also be insulated between the solid

Damper

Damper

Closed

Open

 

Combustion

 

Air Actuator

Figure 3

LOCATION OF FIREPLACE

Carefully select the proper location for heat circulation, aesthetics, chimney obstructions and clearance to side wall(s). With proper pre- planning, a slight adjustment of a few inches can save considerable time and expense later during construction and assembly.

Hearth

Hearth

Optional

4

Figure 2

WARNING: IF INSULATION IS USED, THE FIREPLACE MUST NOT BE PLACED DI- RECTLY AGAINST IT. INSULATION OR VAPOR BARRIERS, IF USED, MUST FIRST BE COVERED WITH GYPSUM BOARD, PLYWOOD, PARTICLE BOARD OR OTHER MATERIAL TO ASSURE INSULATION AND VAPOR BARRIERS REMAIN IN PLACE.

WARNING: DO NOT PACK OR FILL RE- QUIRED AIR SPACES WITH INSULATION OR OTHER MATERIAL. NO MATERIAL IS ALLOWED IN THESE AREAS.

continuous floor beneath the fireplace and the chase bottom. Chase insulation in a cold cli- mate installation is not required for safety.

ASSEMBLY OUTLINE

Before You Start

Check your inventory list to be sure you have all the necessary parts supplied in good usable condition. Check also for any concealed damage.

Check the operation of the damper. The damper is controlled through the use of a control lever located within the firebox opening at the top center just behind the firebox lintel (Figure 3 ). The control lever snaps into place at the ex- treme range of motion, up and back in the closed position. When pulled forward and down, the damper is open.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Outside Chase

Figure 4

Carefully consider the position of the fireplace opening with respect to the location of adja- cent or nearby stairwells, bath or kitchen ex- haust fans and/or return air registers for forced air furnaces/air conditioners that could cause a smoking fireplace condition if the house is tightly insulated.

When locating the fireplace, consideration must be given to combustibles and final finishing. See Figure 5 and confine the final location of combustible finish materials to the "Safe Zone".

DO NOT permanently place furniture or other items such as decorative pillows within 60" of the fireplace front face.

Image 4
Contents Retain These Instructions For Future Reference Wood Burning Fireplaces850,006M REV. C 04/2004 WH Report NoTable of Contents Typical Installation PrecautionsIntroduction Clearances and Height RequirementsAssembly Outline Chimney HeightChase Enclosure Location of FireplaceAssembly Steps PRE-INSTALLATION NotesInstalling the Fireplace Combustible Wall HearthFireplace Specifications Consult all local codesFront Left SideFraming Specifications Installing the Chimney System 8d nails when completely installedChimney 30 Offset Through Floor Or Ceiling Attic Above Firestop SpacerRoof Pitch Model Flat to 6/12 12 to 12/12Using a FTF13-CT2 Chase Termination Using a FTF13-CT1 Chase TerminationTEN Foot Rule Summary Special Offset Instructions Multiple TerminationsOffset Calculations Height FTF13 Vertical Elevation ChartChimney Only FTF13 Offset Elevation Chart Installing OffsetsReturn Elbow Assembly Offset Elbow AssemblyCombustion Air Kits Cold Climate Insulation Optional Equipment ConsiderationsFireplace Finishes Hearth Extensions and Wall Shields Methods of Determining Hearth Extension EquivalentsFinish to Your Taste Installation ComponentsSum of all R values is 70 + .10 + .068 + .5825 = Round Termination 63L44 Page 850,006M REV. C 04/2004 West Taft Avenue Orange, CA

EST-48 specifications

Lucent Technologies EST-48 is a cutting-edge telecommunications platform designed to enhance voice and data connectivity for enterprises and service providers alike. As a versatile solution, the EST-48 combines robust functionalities with advanced technology to meet the growing demands of modern communication infrastructures.

One of the main features of the EST-48 is its seamless integration capabilities. It allows organizations to unify their voice, video, and data services over a single network, thereby simplifying management and reducing operational costs. This integration is crucial for businesses looking to streamline their communication systems and improve collaboration among employees.

The EST-48 utilizes a modular architecture, providing flexibility and scalability to accommodate varying organizational needs. This modularity enables businesses to start with a basic configuration and expand their systems as they grow, adding new capabilities and services without significant disruptions. This characteristic is particularly beneficial for rapidly evolving enterprises.

In terms of technology, the EST-48 is equipped with advanced switching and routing capabilities, ensuring efficient data transmission and reduced latency. Its support for Voice over Internet Protocol (VoIP) technology allows for high-quality voice communications over the internet, significantly improving the clarity and reliability of calls. Additionally, the platform supports a variety of communication standards, making it compatible with existing infrastructure and third-party equipment.

Another significant characteristic of the EST-48 is its emphasis on security. The platform incorporates various security measures to protect sensitive data and prevent unauthorized access. This includes features such as encryption, secure access controls, and regular software updates to safeguard against potential vulnerabilities.

Moreover, the EST-48 comes with robust management tools that provide real-time monitoring and reporting capabilities. These tools enable administrators to track system performance, identify issues, and optimize the network for better efficiency.

In conclusion, Lucent Technologies EST-48 stands out as a versatile communications platform that combines advanced technology with user-friendly features. Its integration capabilities, modular design, emphasis on security, and management tools make it an ideal choice for organizations seeking to improve their communication systems in a cost-effective manner. As communication technology continues to evolve, platforms like the EST-48 will remain essential in meeting the needs of modern enterprises and service providers.