Lucent Technologies EST-48 Typical Installation, Precautions, Introduction, Chimney System

Page 3

PRECAUTIONS

Note: These fireplace systems are not difficult to install. However, in the interest of safety, it is recommended that the installer be a quali- fied or certified “tradesman” familiar with com- monly accepted fireplace installation and safety techniques as well as prevailing local codes.

The most important areas of concern dealing with the installation of factory-built fireplaces are clearances to combustible materials, proper assembly of component parts, height of the chimney system, the proper use of accesso- ries supplied by the manufacturer and the techniques employed in using finishing mate- rials applied to the wall surrounding the fire- place, hearth extensions and wall shields. Each of these topics will be covered in thorough detail throughout this manual. Please give each your special attention as you progress with your installation.

INTRODUCTION

General Information

These fireplaces are conventional radiant heat fireplaces with standard bar grates, optional outside combustion air kits and optional deco- rative glass doors.

TYPICAL INSTALLATION

Figure 1

Note: Illustrations shown reflect “typical” instal- lations with nominal dimensions and are for design and framing reference only. Actual instal- lations may vary due to individual design prefer- ences. However, always maintain minimum clear- ances to combustible materials and do not vio- late any specific installation requirements.

These fireplaces have been tested and listed by Warnock Hersey (Report No. 629-915173) to U.L. standard 127. These units are intended for installation in residential homes and other buildings of conventional construction includ- ing commercial, not in mobile homes.

These fireplace systems are designed for in- stallation in accordance with the National Fire Protection Standard for chimneys, fireplaces and solid fuel burning appliances; NFPA 211 and in accordance with codes such as the BOCA Basic/National Codes, the Standard Me- chanical Code and the Uniform Building Codes.

WARNING: FAILURE TO USE MANUFAC- TURE PROVIDED PARTS, VARIATIONS IN TECHNIQUES AND CONSTRUCTION MA- TERIALS OR PRACTICES OTHER THAN THOSE DESCRIBED IN THIS MANUAL MAY CREATE A FIRE HAZARD AND VOID THE LIMITED WARRANTY.

Chimney and

Termination

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

When complete these fireplace systems con- sists of four basic “sub-systems”:

1.The Fireplace

2.The Chimney and Termination

3.The Optional Glass Doors

4.The Optional Combustion Air Kits

CLEARANCES AND HEIGHT

REQUIREMENTS

The fireplace may be placed on or near normal construction materials*. The combustion air kit, firestop spacer and roof flashing (not chase flashings) may be placed directly on or against normal construction materials.* The chimney and fireplace outer wrapper require a mini- mum 2" air space to combustibles. A combus- tible mantle may be installed 12" above the opening of the fireplace as per NFPA 211, Section 7-2.3.3.

The minimum installed height of the completed fireplace system is 15' 6". The maximum height is 80' 0".

The fireplace and chimney system must be enclosed when installed in or passing through a living area where combustibles or people may come in contact with it. This is important to prevent possible personal injury or fire hazard.

For questions, please call your distributor or the manufacturer. Special restrictions apply to the front and facing of the fireplace and nearby walls (See pages 16 and 17 ).

CHIMNEY SYSTEM

These fireplaces are designed and code listed for use with Security Chimneys FTF13 chimney System only. Always use Security Chimneys FTF13 chimney components with these fire- places. Do not modify or alter these compo- nents as this may cause a potential serious hazard and void the Warranty.

*Construction Materials:

 

• framing materials

• paneling

• particle board

• flooring

• millboard

• dry wall

• plywood

• etc.

3

Image 3
Contents WH Report No Retain These Instructions For Future ReferenceWood Burning Fireplaces 850,006M REV. C 04/2004Table of Contents Clearances and Height Requirements Typical InstallationPrecautions IntroductionLocation of Fireplace Assembly OutlineChimney Height Chase EnclosureCombustible Wall Hearth Assembly StepsPRE-INSTALLATION Notes Installing the FireplaceLeft Side Fireplace SpecificationsConsult all local codes FrontFraming Specifications Attic Above Firestop Spacer Installing the Chimney System8d nails when completely installed Chimney 30 Offset Through Floor Or Ceiling12 to 12/12 Roof Pitch Model Flat to 6/12Using a FTF13-CT1 Chase Termination Using a FTF13-CT2 Chase TerminationTEN Foot Rule Summary Multiple Terminations Special Offset InstructionsOffset Calculations FTF13 Vertical Elevation Chart HeightChimney Only Installing Offsets FTF13 Offset Elevation ChartOffset Elbow Assembly Return Elbow AssemblyCombustion Air Kits Optional Equipment Considerations Cold Climate InsulationFireplace Finishes Methods of Determining Hearth Extension Equivalents Hearth Extensions and Wall ShieldsInstallation Components Finish to Your TasteSum of all R values is 70 + .10 + .068 + .5825 = Round Termination 63L44 Page West Taft Avenue Orange, CA 850,006M REV. C 04/2004

EST-48 specifications

Lucent Technologies EST-48 is a cutting-edge telecommunications platform designed to enhance voice and data connectivity for enterprises and service providers alike. As a versatile solution, the EST-48 combines robust functionalities with advanced technology to meet the growing demands of modern communication infrastructures.

One of the main features of the EST-48 is its seamless integration capabilities. It allows organizations to unify their voice, video, and data services over a single network, thereby simplifying management and reducing operational costs. This integration is crucial for businesses looking to streamline their communication systems and improve collaboration among employees.

The EST-48 utilizes a modular architecture, providing flexibility and scalability to accommodate varying organizational needs. This modularity enables businesses to start with a basic configuration and expand their systems as they grow, adding new capabilities and services without significant disruptions. This characteristic is particularly beneficial for rapidly evolving enterprises.

In terms of technology, the EST-48 is equipped with advanced switching and routing capabilities, ensuring efficient data transmission and reduced latency. Its support for Voice over Internet Protocol (VoIP) technology allows for high-quality voice communications over the internet, significantly improving the clarity and reliability of calls. Additionally, the platform supports a variety of communication standards, making it compatible with existing infrastructure and third-party equipment.

Another significant characteristic of the EST-48 is its emphasis on security. The platform incorporates various security measures to protect sensitive data and prevent unauthorized access. This includes features such as encryption, secure access controls, and regular software updates to safeguard against potential vulnerabilities.

Moreover, the EST-48 comes with robust management tools that provide real-time monitoring and reporting capabilities. These tools enable administrators to track system performance, identify issues, and optimize the network for better efficiency.

In conclusion, Lucent Technologies EST-48 stands out as a versatile communications platform that combines advanced technology with user-friendly features. Its integration capabilities, modular design, emphasis on security, and management tools make it an ideal choice for organizations seeking to improve their communication systems in a cost-effective manner. As communication technology continues to evolve, platforms like the EST-48 will remain essential in meeting the needs of modern enterprises and service providers.