Lucent Technologies EST-48 Offset Elbow Assembly, Return Elbow Assembly, Combustion Air Kits

Page 14

14

Underside Of Chimney

Figure 38

FTF13-E30 Return Elbow*

Chimney Section (S)

FTF13-30 Offset Elbow*

B

A

*Part of Offset/Return Package Model FTF13-ES30

Figure 39

Note: See Framing and Dimension Chart for the sizes of the ceiling and roof openings. The size of the roof opening varies with the degree of pitch of the roof.

Offset Elbow Assembly

Offset elbows install the same as chimney sections. First, snap the inner section INTO the preceding inner section of flue. Check connec- tion by pulling up slightly to ensure a tight fit. Next, the outer sections snap lock OVER the preceding outer section of chimney. Again, check outer section by pulling up slightly to ensure proper connection is made.

Return Elbow Assembly

Return elbows install the same way as round terminations and stabilizers:

Step 1. Hold return elbow over top of last chimney section.

Step 2. Center inner slip section into inner flue pipe-slip down.

Step 3. Center outer-locking section over outer chimney pipe. Push down until locking joint has firmly engaged.

Step 4. Pull up slightly on return elbow to ensure locking joint has firmly engaged.

Step 5. Secure support straps to framing members by nailing under tension in sheer (Figure 40 ).

Return

Elbow

Figure 40

Note: The return elbow assembly performs the same function as a stabilizer. Consider this when determining the need for a stabilizer.

Note: Do not apply excessive pressure to any subsequent chimney section following return elbow assembly when installing. Ensure that each subsequent chimney section is securely attached by testing as noted above.

Combustion Air Kits

The installation of an outside combustion air kit is highly recommended. It is very impor- tant to ensure good fireplace operation in homes which are tightly weather sealed or have ventilating appliances installed.

Step 1. Determine the source for outside air, which can be installed through an outside wall or into a ventilated crawl space. In either case, a 4 1/2" diameter hole will be required for installation of the air inlet assembly.

CAUTION: AVOID INSTALLING THE AIR IN- LET WHERE THE OPENING COULD BE BLOCKED BY SNOW, BUSHES OR OTHER OBSTACLES. THE MAXIMUM HEIGHT FOR THE OUTSIDE AIR IS 50 FEET ABOVE THE HEARTH, PROVING THE AIR INLET IS TERMI- NATED A MINIMUM OF THREE (3) FEET BE- LOW THE CHIMNEY CAP LEVEL.

Note: Combustion air inlet ducts must not terminate in attic space.

Step 2. Install the air inlet eyebrow (FOAK-4 or FOAK-4LD) through the wall opening (Figure 41). Push a 4 inch diameter NON-COMBUSTIBLE Class 0 or Class I flexible duct onto the eyebrow.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

AIR INLET

EYEBROW

ASSEMBLY

FOAK

Figure 41

Step 3. The air inlet for the outside air kit is located on the right hand side of the fireplace (Figure 42 ). Refer to the installation instruc- tions packed with each FOAK-4 air kit for specific installation information. The outside air kit, if used, must be installed before the fireplace is totally framed and enclosed within the finished walls.

OPEN

CLOSED

Figure 42

After completing the installation of the optional combustion air vent system, the actuator arm must be put in service and tested to ensure proper operation before completing any enclo- sure around the firebox. Failure to do so may result in extensive and costly rework.

To operate, locate the hand operated shut-off lever at the lower right side of the fireplace opening behind the screen. To open the air damper, turn upwards. To close, turn down.

Operate the actuator through several cycles. Ensuring proper operation and freedom of movement. Return the actuator arm to the closed position.

Image 14
Contents 850,006M REV. C 04/2004 Retain These Instructions For Future ReferenceWood Burning Fireplaces WH Report NoTable of Contents Introduction Typical InstallationPrecautions Clearances and Height RequirementsChase Enclosure Assembly OutlineChimney Height Location of FireplaceInstalling the Fireplace Assembly StepsPRE-INSTALLATION Notes Combustible Wall HearthFront Fireplace SpecificationsConsult all local codes Left SideFraming Specifications Chimney 30 Offset Through Floor Or Ceiling Installing the Chimney System8d nails when completely installed Attic Above Firestop SpacerRoof Pitch Model Flat to 6/12 12 to 12/12TEN Foot Rule Summary Using a FTF13-CT1 Chase TerminationUsing a FTF13-CT2 Chase Termination Offset Calculations Multiple TerminationsSpecial Offset Instructions Chimney Only FTF13 Vertical Elevation ChartHeight FTF13 Offset Elevation Chart Installing OffsetsCombustion Air Kits Offset Elbow AssemblyReturn Elbow Assembly Fireplace Finishes Optional Equipment ConsiderationsCold Climate Insulation Hearth Extensions and Wall Shields Methods of Determining Hearth Extension EquivalentsSum of all R values is 70 + .10 + .068 + .5825 = Installation ComponentsFinish to Your Taste Round Termination 63L44 Page 850,006M REV. C 04/2004 West Taft Avenue Orange, CA

EST-48 specifications

Lucent Technologies EST-48 is a cutting-edge telecommunications platform designed to enhance voice and data connectivity for enterprises and service providers alike. As a versatile solution, the EST-48 combines robust functionalities with advanced technology to meet the growing demands of modern communication infrastructures.

One of the main features of the EST-48 is its seamless integration capabilities. It allows organizations to unify their voice, video, and data services over a single network, thereby simplifying management and reducing operational costs. This integration is crucial for businesses looking to streamline their communication systems and improve collaboration among employees.

The EST-48 utilizes a modular architecture, providing flexibility and scalability to accommodate varying organizational needs. This modularity enables businesses to start with a basic configuration and expand their systems as they grow, adding new capabilities and services without significant disruptions. This characteristic is particularly beneficial for rapidly evolving enterprises.

In terms of technology, the EST-48 is equipped with advanced switching and routing capabilities, ensuring efficient data transmission and reduced latency. Its support for Voice over Internet Protocol (VoIP) technology allows for high-quality voice communications over the internet, significantly improving the clarity and reliability of calls. Additionally, the platform supports a variety of communication standards, making it compatible with existing infrastructure and third-party equipment.

Another significant characteristic of the EST-48 is its emphasis on security. The platform incorporates various security measures to protect sensitive data and prevent unauthorized access. This includes features such as encryption, secure access controls, and regular software updates to safeguard against potential vulnerabilities.

Moreover, the EST-48 comes with robust management tools that provide real-time monitoring and reporting capabilities. These tools enable administrators to track system performance, identify issues, and optimize the network for better efficiency.

In conclusion, Lucent Technologies EST-48 stands out as a versatile communications platform that combines advanced technology with user-friendly features. Its integration capabilities, modular design, emphasis on security, and management tools make it an ideal choice for organizations seeking to improve their communication systems in a cost-effective manner. As communication technology continues to evolve, platforms like the EST-48 will remain essential in meeting the needs of modern enterprises and service providers.