Regency U37-NG1, U37-LP1 installation manual 6-5/8 Rigid Pipe Cross Reference Chart

Page 11

INSTALLATION

4” x 6-5/8” Rigid Pipe Cross Reference Chart (Cont.)

Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.

Description

Simpson

Simpson

Selkirk

American Metal

Metal-Fab®

Security

Direct Vent GS®

Products

®

Direct Vent Pro®

Discontinued

Direct-Temp™

 

Sure Seal

Secure Vent®

 

 

 

Amerivent Direct

 

 

Attic Insulation Shield 12”

46DVA-IS - N/A from FPI

N/A

N/A

4DAIS12

 

N/A

SV4RSA

Attic Insulation Shield - Cold Climates 36”

N/A

N/A

N/A

4DAIS36

 

N/A

N/A

Basic Horizontal Termination Kit (A)

Horizontal Termination Kit (B)

Vertical Termination Kit

DISC. 46DVA-KHA (Changed Components) DISC.

970

971

978

4DT-HKA

4DT-HKB

4DT-VKC

4DHTK2

4DHTK1

4DVTK

4DHTKA

4DHTKB

4DVTK

SV - SHK

SV - HK

SV - FK

High Wind Vertical Cap

High Wind Horizontal Cap

Horizontal Square Termination Cap

Vertical Termination Cap

Storm Collar

46DVA-VCH

46DVA-HC

Disc - See 46DVA-HC 46DVA-VC 46DVA-SC

991

985

984

980

953

N/A

N/A 4DT-HHC 4DT-HVC 4DT-SC

N/A

N/A

4DHC

4DVC

4DSC

N/A

N/A

4DHT

4DVT

4DSC

N/A

N/A SV4CHC-1 SV4CGV-1 SV4FC

Adjustable Flashing, 0/12-6/12 Adjustable Flashing, 6/12-12/12

46DVA-F6 46DVA-F12

943

943S

4DT-AF6 4DT-AF12

4DF

4DF12

4DF 4DF-12

SV4FA

SV4FB

Vinyl Siding Standoff Vinyl Siding Shield Plate

46DVA-VSS N/A

950

N/A

4DT-VS 4DT-VSP

N/A

N/A

4DVS

N/A

SV4VS

SV4VS

Snorkel Termination 14” Snorkel Termination 36”

46DVA-SNK14 N/A

982

981

4DT-ST14 4DT-ST36

4D12S

4D36S

4DST14

4DST36

SV4STC14

SV4STC36

Restrictor Disk

Extended Vertical Termination Cap

Chimney Conversion Kit A

Chimney Conversion Kit B

Chimney Conversion Kit C

Chimney Conversion Kit Masonry

Mansonry Chimney Conversion Kit

(includes: Cap Adapter 18”x18” Flashing)

Wall Firestop

Colinear Flex Connectors

46DVA-RD 46DVA-VCE 46DVA-KCA 46DVA-KCB 46DVA-KCC 46DVA-KMC

46DVA-KCT

46DVA-WFS 46DVA-ADF

929

930

931

932

933

934

935

947

923F

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

FPI

946-506/P

Vent Guard (Optional) for AstropCap

946-205

Vinyl Siding Shield for Riser Vent Terminal

510-994

Rigid Pipe Adapter (Must use with all Rigid Piping)

946-208/P

Vent Guard (Optional) for Riser Vent Terminal

640-530/P

Riser Vent Terminal

946-523/P

AstroCap Horizontal Cap

 

 

946-206

Vinyl Siding Standoff for AstroCap

 

 

 

 

*NOTE: When using Metal-Fab Sure Seal Rigid Piping please note that either the Adaptor (4DDA) or 90º Starter Elbow (4D90A) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).

Offset Pipe Selection:

Use this table to determine offset pipe lengths.

Pipe Length

4” x 6-5/8” Venting

Run (X)

Rise (Y)

 

0”(0mm)

4-7/8”(124mm)

13-3/8”(340mm)

6”(152mm)

8”(203mm)

16-1/2”(419mm)

 

 

 

9”(229mm)

10-1/8”(257mm)

18-5/8”(473mm)

 

 

 

12”(305mm)

12-1/4”(311mm)

20-3/4”(527mm)

 

 

 

24”(610mm)

20-5/8”(524mm)

29-1/8”(740mm)

36”(914mm)

29”(737mm)

37-1/2”(953mm)

 

 

 

48”(1219mm)

37-7/16”(951mm)

45-15/16”(1167mm)

 

 

 

L

X

Y

For specifi c instructions or details on particular venting components please visit the following websites:

Simpson Direct Vent Pro: www.duravent.com

Selkirk Direct-Temp: www.selkirkcorp.com

American Metal Products Amerivent Direct: www.americanmetalproducts.com

Metal-Fab Sure Seal: www.mtlfab.com

Security Secure Vent: www.securitychimneys.com

NOTE: Horizontal runs of vent must be level, or have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present a possible fire hazard.

U37-1 Regency® ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove

11

Image 11
Contents Ultimate U37 Rear Vent To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Label for U37 Safety LabelMA Code CO Detector RequirementsImportant Message Save These Instructions InstallationSpecifications General Safety InformationLocating Your GAS Stove Installation ChecklistManufactured Mobile Home Additional Requirements Clearances to CombustiblesExterior Vent Terminal Locations Planning Your Venting Installation Venting Installation PrecautionsSafety Precautions For the Installer Description 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Vent Restrictor Position Using Rigid Piping SystemsStraight Vertical Terminations Offset to Vertical TerminationsSnorkel Terminations Horizontal TerminationsOptional Components Alternate Snorkel Termination CapHint Apply sealant to female end Below Grade Snorkel InstallationAlternate Approved Caps Vertical Termination with CO-LINEAR Flex SystemRequired Parts Description Converting a Factory Built Metal Chimney Approved for US Installations OnlyGeneral Converting Masonry Chimney Conversion Kit Contains Qty Conversion KIT# 514-969 from NG to LPGlow on logs High Elevation Aeration AdjustmentLOG SET Installation GAS ConnectionA02-65 Ports on the valve Door Installation GAS Pipe Pressure TestingValve Description Final Check Louver InstallationOptional Remote Control Wall ThermostatAway from sharp edges Wiring DiagramFirst Fire Lighting ProcedureOperating Instructions Operating InstructionsGas Control Valve Copy of the Lighting Plate InstructionsBlower Thermodisc Pilot FlameMaintenance Removing Glass Latch AdjustmentGlass Replacement Installing GlassReplacing Fan FAN MaintenanceRemoving Valve DC Sparker Battery Replacement Main Assembly Parts ListBurner & LOG Assembly Door Assemblies Page Conditions WarrantyInstaller Please complete the following information
Related manuals
Manual 36 pages 8.33 Kb

U37-LP1, U37-NG1 specifications

The Regency U37-NG1 and U37-LP1 are two innovative models that showcase advanced technology and superior engineering in the realm of HVAC (heating, ventilation, and air conditioning) systems. These units are designed to deliver optimal comfort while maximizing energy efficiency, making them ideal for both residential and commercial applications.

One of the standout features of the U37-NG1 is its use of a high-efficiency burner system, which ensures that every unit is capable of delivering substantial heating output while consuming minimal gas. This not only translates to lower utility bills for users but also aligns with sustainability goals by reducing carbon emissions. In terms of design, the U37-NG1 is compact and can be installed in a variety of settings, making it a versatile choice for many different environments.

The U37-LP1, on the other hand, is tailored for propane applications, making it perfect for areas where natural gas is inaccessible. It features a similar high-efficiency heating output, ensuring that it meets the demands of users without compromising on performance. The dual-fuel capability of the U37 series enhances its adaptability, allowing it to be used in a range of scenarios.

Both models are equipped with advanced control technologies, including programmable thermostats and smart connectivity features. Users can easily manage their heating systems through mobile apps, allowing for remote adjustments and real-time monitoring. This technology not only enhances user convenience but also promotes energy conservation by allowing users to adjust settings based on their lifestyle and preferences.

In terms of durability, the Regency U37 series boasts a robust construction designed to withstand various environmental conditions. With quality materials and expert craftsmanship, these units are built to last, reducing the need for frequent repairs or replacements.

Overall, the Regency U37-NG1 and U37-LP1 models combine cutting-edge technology with practical features to deliver an exceptional heating experience. Their commitment to energy efficiency, adaptability, and user-friendly controls positions them as leading options in the HVAC market, making comfortable living spaces more accessible while promoting environmentally responsible practices. Whether for home use or commercial properties, these systems offer reliability and performance tailored to the needs of modern users.