Regency U37-NG1 Vertical Termination with CO-LINEAR Flex System, Required Parts Description

Page 15

INSTALLATION

VERTICAL TERMINATION WITH

CO-LINEAR FLEX SYSTEM

THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING

A SEPARATE SOLID FUEL BURNING APPLIANCE.

This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney. See the Venting Ar- rangements chart in the "Rigid Pipe Venting - Vertical Terminations" section for minimum and maximum fl ue lengths.See chart below for minimum distances from roof. Periodically check that the vent is unrestricted.

Masonry chimneys may take various contours which the fl exible liner will accommodate. However, keep the flexible liner as straight as possible, avoid unnecessary bending.

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

Required Parts:

 

 

Part #

Description

 

 

946-529

Co-linear DV Vertical Termination Cap

 

948-305

3" Flex - 35 ft.

 

 

640-994

U37 Rigid Pipe Adaptor

 

 

946-563

Co-Axial to Co-Linear Adapter Kit

 

 

which contains the following:

 

 

Co-linear Flex Adapter (270-585)

 

 

Outer Pipe (946-257)

 

 

 

Inner Pipe Adapter (946-219)

 

Alternate Approved Caps

Co-linear DV

 

980

Vertical Termination Cap

 

991

High Wind Cap

Vertical Termination

 

Cap # 946-529

 

923GK

3" Co-linear Adapter

 

 

with fl ashing

 

 

 

 

Check local

 

 

 

codes whether

 

 

 

a continuous

 

 

 

length is re-

 

 

 

quired or if

Flex Liner

 

 

certified joiner

 

 

 

kits may

 

 

 

be used.

 

 

 

#948-305

 

 

 

(35 ft)

 

 

 

Exhaust

 

 

 

Flue

 

U37 Rigid Pipe

Adaptor

Part # 640-994

Air Intake

 

Co-Linear

 

Flex

 

Adapter

 

with Kit#

 

946-563

Inner Pipe

 

Adapter

Outer

with Kit#

946-563

Pipe

 

with Kit#

 

946-563

U37-1 Regency® ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove

15

Image 15
Contents Ultimate U37 Rear Vent To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Label for U37 Safety LabelMA Code CO Detector RequirementsImportant Message Save These Instructions InstallationSpecifications General Safety InformationLocating Your GAS Stove Installation ChecklistManufactured Mobile Home Additional Requirements Clearances to CombustiblesExterior Vent Terminal Locations Venting Installation Precautions Safety Precautions For the InstallerPlanning Your Venting Installation Description 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Vent Restrictor Position Using Rigid Piping SystemsStraight Vertical Terminations Offset to Vertical TerminationsSnorkel Terminations Horizontal TerminationsOptional Components Alternate Snorkel Termination CapHint Apply sealant to female end Below Grade Snorkel InstallationVertical Termination with CO-LINEAR Flex System Required Parts DescriptionAlternate Approved Caps Approved for US Installations Only GeneralConverting a Factory Built Metal Chimney Converting Masonry Chimney Conversion Kit Contains Qty Conversion KIT# 514-969 from NG to LPGlow on logs High Elevation Aeration AdjustmentLOG SET Installation GAS ConnectionA02-65 Door Installation GAS Pipe Pressure Testing Valve DescriptionPorts on the valve Final Check Louver InstallationOptional Remote Control Wall ThermostatAway from sharp edges Wiring DiagramFirst Fire Lighting ProcedureOperating Instructions Operating InstructionsGas Control Valve Copy of the Lighting Plate InstructionsBlower Thermodisc Pilot FlameMaintenance Removing Glass Latch AdjustmentGlass Replacement Installing GlassFAN Maintenance Removing ValveReplacing Fan DC Sparker Battery Replacement Main Assembly Parts ListBurner & LOG Assembly Door Assemblies Page Conditions WarrantyInstaller Please complete the following information
Related manuals
Manual 36 pages 8.33 Kb

U37-LP1, U37-NG1 specifications

The Regency U37-NG1 and U37-LP1 are two innovative models that showcase advanced technology and superior engineering in the realm of HVAC (heating, ventilation, and air conditioning) systems. These units are designed to deliver optimal comfort while maximizing energy efficiency, making them ideal for both residential and commercial applications.

One of the standout features of the U37-NG1 is its use of a high-efficiency burner system, which ensures that every unit is capable of delivering substantial heating output while consuming minimal gas. This not only translates to lower utility bills for users but also aligns with sustainability goals by reducing carbon emissions. In terms of design, the U37-NG1 is compact and can be installed in a variety of settings, making it a versatile choice for many different environments.

The U37-LP1, on the other hand, is tailored for propane applications, making it perfect for areas where natural gas is inaccessible. It features a similar high-efficiency heating output, ensuring that it meets the demands of users without compromising on performance. The dual-fuel capability of the U37 series enhances its adaptability, allowing it to be used in a range of scenarios.

Both models are equipped with advanced control technologies, including programmable thermostats and smart connectivity features. Users can easily manage their heating systems through mobile apps, allowing for remote adjustments and real-time monitoring. This technology not only enhances user convenience but also promotes energy conservation by allowing users to adjust settings based on their lifestyle and preferences.

In terms of durability, the Regency U37 series boasts a robust construction designed to withstand various environmental conditions. With quality materials and expert craftsmanship, these units are built to last, reducing the need for frequent repairs or replacements.

Overall, the Regency U37-NG1 and U37-LP1 models combine cutting-edge technology with practical features to deliver an exceptional heating experience. Their commitment to energy efficiency, adaptability, and user-friendly controls positions them as leading options in the HVAC market, making comfortable living spaces more accessible while promoting environmentally responsible practices. Whether for home use or commercial properties, these systems offer reliability and performance tailored to the needs of modern users.