TheULTIMATERearVentDirectVentFreestand- ing Gas Stove must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the building authority having jurisdiction to deter- mine the need for a permit prior to starting the installation.

Note: Failure to follow the instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or prop- erty damage. Failure to follow these instructions may also void your fire insurance and/or warranty.

SPECIFICATIONS

Fuels: U37-NG1 is approved for use with natural gas.

U37-LP1 is approved for use with liq- uefi ed petroleum gases (propane).

Electrical: 120 V A.C. system.

Circulation Fan: Variable speed, 125/75.

Log Sets: Ceramic fi bre, 7 per set.

Vent System:

Axial (6-5/8" outer / 4" inner liner) rigid fl ue and Riser Vent Terminal.

BEFORE YOU START

Safe installation and operation of this appli- ance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

INSTALLATION AND REPAIRS SHOULD BE DONE BY A QUALI- FIEDSERVICEPERSON.THISAP- PLIANCESHOULDBEINSTALLED, REPAIRED, INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A QUALIFIED SERVICE PER- SON. MORE FREQUENT CLEAN- ING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPET- ING, ETC. IT IS IMPERATIVE THAT THE CONTROL COMPARTMENT, BURNERSANDCIRCULATINGAIR PASSAGEWAYS OF THE APPLI- ANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILLVOIDYOURWARRANTYAND MAY CAUSE A SERIOUS HOUSE FIRE.

CHILDRENANDADULTSSHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERA- TURES, ESPECIALLY THE FIRE- PLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEYAREINTHESAMEROOMAS THE APPLIANCE.

CLOTHING OR OTHER FLAM- MABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.

1)Provide adequate clearances for servicing, properoperationandaroundtheairopenings into the combustion chamber.

2)The appliance must be installed on a fl at, solid, continuous surface (e.g. wood, metal, concrete). This may be the fl oor, or it can be raised up on a platform to enhance its visual impact. The appliance may be installed on carpeting, tile, wood fl ooring or other com- bustible material, because the appliance's metal pedestal base extends the full width and depth of the appliance. The ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove can be installed in a wide variety of ways and will fi t nearly any room layout. It may be installed in a recessed position, framed out into the room, or across a cor- ner.

3)The ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove is approved for manufactured home installations, see "Clearances to Combustible" to "Rigid Pipe Venting - Vertical Terminations" section for the required vent arrangements. If installed

into a manufactured home the unit must be bolted down to the fl oor.

4)We recommend that you plan your instal- lation on paper using exact measurements for clearances and fl oor protection before actually installing this appliance. Have a qualifiedbuildinginspectorreviewyourplans before installation.

GENERAL SAFETY

INFORMATION

1)Theappliance installation mustconformwith local Canadian Electrical Code.

2)The appliance when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code.

3)The appliance should be inspected for shipping damage before use and serv- iced annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpet- ing, bedding material, etc. It is imperative that control compartments, and circulating air passageways of the appliance be kept clean and free from excessive lint from carpeting.

4)See general construction and assembly instructions. The appliance and vent should be enclosed when installed in or passing through a living area, where children may come in contact with it.

5)This appliance must be connected to the specifi ed vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fi tted as per the instruc- tions starting in the "Venting" section.

6)Inspect the venting system annually for blockage and any signs of deterioration.

7)Venting terminals shall not be recessed into a wall or siding.

8)Any safety glass removed for servicing must be replaced prior to operating the ap- pliance.

9)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fi replace.

Emissions from burning wood or gas could contain chemicals known to the State of Cali- fornia to cause cancer, birth defects or other reproductive harm.

6

U37-1 Regency® ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove

Image 6
Contents Ultimate U37 Rear Vent Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Copy of Safety Label for U37Requirements MA Code CO DetectorGeneral Safety Information InstallationSpecifications Important Message Save These InstructionsClearances to Combustibles Installation ChecklistManufactured Mobile Home Additional Requirements Locating Your GAS StoveExterior Vent Terminal Locations Venting Installation Precautions Safety Precautions For the InstallerPlanning Your Venting Installation 6-5/8 Rigid Pipe Cross Reference Chart Description6-5/8 Rigid Pipe Cross Reference Chart Offset to Vertical Terminations Using Rigid Piping SystemsStraight Vertical Terminations Vent Restrictor PositionAlternate Snorkel Termination Cap Horizontal TerminationsOptional Components Snorkel TerminationsBelow Grade Snorkel Installation Hint Apply sealant to female endVertical Termination with CO-LINEAR Flex System Required Parts DescriptionAlternate Approved Caps Approved for US Installations Only GeneralConverting a Factory Built Metal Chimney Converting Masonry Chimney Conversion KIT# 514-969 from NG to LP Conversion Kit Contains QtyGlow on logs GAS Connection Aeration AdjustmentLOG SET Installation High ElevationA02-65 Door Installation GAS Pipe Pressure Testing Valve DescriptionPorts on the valve Wall Thermostat Louver InstallationOptional Remote Control Final CheckWiring Diagram Away from sharp edgesOperating Instructions Lighting ProcedureOperating Instructions First FirePilot Flame Copy of the Lighting Plate InstructionsBlower Thermodisc Gas Control ValveMaintenance Installing Glass Latch AdjustmentGlass Replacement Removing GlassFAN Maintenance Removing ValveReplacing Fan DC Sparker Battery Replacement Parts List Main AssemblyBurner & LOG Assembly Door Assemblies Page Warranty ConditionsInstaller Please complete the following information
Related manuals
Manual 36 pages 8.33 Kb

U37-LP1, U37-NG1 specifications

The Regency U37-NG1 and U37-LP1 are two innovative models that showcase advanced technology and superior engineering in the realm of HVAC (heating, ventilation, and air conditioning) systems. These units are designed to deliver optimal comfort while maximizing energy efficiency, making them ideal for both residential and commercial applications.

One of the standout features of the U37-NG1 is its use of a high-efficiency burner system, which ensures that every unit is capable of delivering substantial heating output while consuming minimal gas. This not only translates to lower utility bills for users but also aligns with sustainability goals by reducing carbon emissions. In terms of design, the U37-NG1 is compact and can be installed in a variety of settings, making it a versatile choice for many different environments.

The U37-LP1, on the other hand, is tailored for propane applications, making it perfect for areas where natural gas is inaccessible. It features a similar high-efficiency heating output, ensuring that it meets the demands of users without compromising on performance. The dual-fuel capability of the U37 series enhances its adaptability, allowing it to be used in a range of scenarios.

Both models are equipped with advanced control technologies, including programmable thermostats and smart connectivity features. Users can easily manage their heating systems through mobile apps, allowing for remote adjustments and real-time monitoring. This technology not only enhances user convenience but also promotes energy conservation by allowing users to adjust settings based on their lifestyle and preferences.

In terms of durability, the Regency U37 series boasts a robust construction designed to withstand various environmental conditions. With quality materials and expert craftsmanship, these units are built to last, reducing the need for frequent repairs or replacements.

Overall, the Regency U37-NG1 and U37-LP1 models combine cutting-edge technology with practical features to deliver an exceptional heating experience. Their commitment to energy efficiency, adaptability, and user-friendly controls positions them as leading options in the HVAC market, making comfortable living spaces more accessible while promoting environmentally responsible practices. Whether for home use or commercial properties, these systems offer reliability and performance tailored to the needs of modern users.