PARTS LIST

 

 

DOOR ASSEMBLIES

 

Part #

Description

 

730-923

Brush Nickel Mitred Door - Complete

 

730-924

Gold Mitred Door - Complete

 

730-926

Black Mitred Door - Complete

 

730-932

Gold Wrap Door - Complete

 

730-928

Gold Panel Door - Complete

101)

650-920

Door Gasket Kit

105)

*

Ceramic Paper

106)

940-323/P

Side Glass

107)

936-243

Glass Gasket

108)

940-322/P

Centre Glass

111)

*

Door Frame Fibre Paper

112)

750-015

Door Glass Extrusion

208)

940-325/P

Wrap Glass

*Not available as a replacement part.

U37-1 Regency® ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove

33

Image 33
Contents Ultimate U37 Rear Vent To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Label for U37 Safety LabelMA Code CO Detector RequirementsSpecifications InstallationGeneral Safety Information Important Message Save These InstructionsManufactured Mobile Home Additional Requirements Installation ChecklistClearances to Combustibles Locating Your GAS StoveExterior Vent Terminal Locations Venting Installation Precautions Safety Precautions For the InstallerPlanning Your Venting Installation Description 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Straight Vertical Terminations Using Rigid Piping SystemsOffset to Vertical Terminations Vent Restrictor PositionOptional Components Horizontal TerminationsAlternate Snorkel Termination Cap Snorkel TerminationsHint Apply sealant to female end Below Grade Snorkel InstallationVertical Termination with CO-LINEAR Flex System Required Parts DescriptionAlternate Approved Caps Approved for US Installations Only GeneralConverting a Factory Built Metal Chimney Converting Masonry Chimney Conversion Kit Contains Qty Conversion KIT# 514-969 from NG to LPGlow on logs LOG SET Installation Aeration AdjustmentGAS Connection High ElevationA02-65 Door Installation GAS Pipe Pressure Testing Valve DescriptionPorts on the valve Optional Remote Control Louver InstallationWall Thermostat Final CheckAway from sharp edges Wiring DiagramOperating Instructions Lighting ProcedureOperating Instructions First FireBlower Thermodisc Copy of the Lighting Plate InstructionsPilot Flame Gas Control ValveMaintenance Glass Replacement Latch AdjustmentInstalling Glass Removing GlassFAN Maintenance Removing ValveReplacing Fan DC Sparker Battery Replacement Main Assembly Parts ListBurner & LOG Assembly Door Assemblies Page Conditions WarrantyInstaller Please complete the following information
Related manuals
Manual 36 pages 8.33 Kb

U37-LP1, U37-NG1 specifications

The Regency U37-NG1 and U37-LP1 are two innovative models that showcase advanced technology and superior engineering in the realm of HVAC (heating, ventilation, and air conditioning) systems. These units are designed to deliver optimal comfort while maximizing energy efficiency, making them ideal for both residential and commercial applications.

One of the standout features of the U37-NG1 is its use of a high-efficiency burner system, which ensures that every unit is capable of delivering substantial heating output while consuming minimal gas. This not only translates to lower utility bills for users but also aligns with sustainability goals by reducing carbon emissions. In terms of design, the U37-NG1 is compact and can be installed in a variety of settings, making it a versatile choice for many different environments.

The U37-LP1, on the other hand, is tailored for propane applications, making it perfect for areas where natural gas is inaccessible. It features a similar high-efficiency heating output, ensuring that it meets the demands of users without compromising on performance. The dual-fuel capability of the U37 series enhances its adaptability, allowing it to be used in a range of scenarios.

Both models are equipped with advanced control technologies, including programmable thermostats and smart connectivity features. Users can easily manage their heating systems through mobile apps, allowing for remote adjustments and real-time monitoring. This technology not only enhances user convenience but also promotes energy conservation by allowing users to adjust settings based on their lifestyle and preferences.

In terms of durability, the Regency U37 series boasts a robust construction designed to withstand various environmental conditions. With quality materials and expert craftsmanship, these units are built to last, reducing the need for frequent repairs or replacements.

Overall, the Regency U37-NG1 and U37-LP1 models combine cutting-edge technology with practical features to deliver an exceptional heating experience. Their commitment to energy efficiency, adaptability, and user-friendly controls positions them as leading options in the HVAC market, making comfortable living spaces more accessible while promoting environmentally responsible practices. Whether for home use or commercial properties, these systems offer reliability and performance tailored to the needs of modern users.