Regency P48-2 installation manual Venting, Introduction, Unit Assembly, Prior to, Installation

Page 11

 

 

 

INSTALLATION

UNIT ASSEMBLY

TOP FACING SUPPORT AND

"C" Screw Position:

PRIOR TO

SIDE NAILING STRIPS

For a facing material depth of 1-1/4" (32mm),

 

 

Determine the total thickness of facing material

the top facing support must be reversed.

INSTALLATION

 

(e.g. drywall

plus ceramic tiles) to allow the

 

The Top Facing Support, the Side Nailing Strips

fi nished surface to be fl ush with the front of the

 

unit. Total facing thickness can vary from 1/2"

 

and the 2 Top Standoffs must be correctly

(13mm) to 1-1/4" (32mm) thick.

 

positioned and attached to the top before unit

 

 

 

is slipped into position.

TheTopFacingSupport&SideNailingStripscan

 

TOP STANDOFF ASSEMBLY

be mounted in 3 different positions depending

 

on the thickness of the facing material.

 

The top standoffs are shipped in a fl at position

 

 

 

and must be folded into shape and attached.

 

 

 

1) Remove the standoffs from the fi replace

Screw

Facing Material Depth

 

Position

 

 

top.

 

 

A

1/2" / 13mm

 

 

 

2) Take each standoff and bend into the correct

B

7/8" / 22mm

 

shape. Bend up at the bend lines until the

 

C*

1-1/4" / 32mm

2) Use the same screw hole position for the

screw holes in the standoff and the pre-

punched screw holes on the fi replace

top

 

 

Side Nailing Strips as was used for the Top

line up.

* For "C" screw position the top facing support

Facing Support. Attach each side nailing

is reversed.

 

strip using 3 screws.

 

 

3) Attach the standoff securely to the

top

 

 

 

with 2 screws per standoff (on opposite

 

 

 

corners).

1)

Mount Top Facing

Support using the 3

 

 

 

 

 

supplied screws into the three pre-punched

 

 

 

screw holes on the top front of the unit. Use

VENTING

 

 

hole positions A, B, or C depending on your

 

 

facing depth.

 

INTRODUCTION

 

 

 

 

 

 

 

 

The P48-2 uses the "balanced flue" technology

 

 

 

 

Co Axial system. The inner liner vents products

 

 

 

 

of combustion to the outside while the outer

 

 

 

 

liner draws outside combustion air into the

 

 

 

 

combustion chamber thereby eliminating the

 

 

 

 

need to use heated room air for combustion and

 

 

 

 

losing warm room air up the chimney.

 

 

 

 

Note: These flue pipes must not be

 

 

 

 

connected to any other appliance.

 

 

 

 

The gas appliance and vent system must be

 

 

 

 

vented directly to the outside of the building,

 

 

 

 

and never be attached to a chimney serving a

 

 

 

 

separate solid fuel or gas burning appliance.

 

 

 

 

Each direct vent gas appliance must use it's own

 

 

 

 

separate vent system. Common vent systems

 

 

 

 

are prohibited.

Regency® P48-2 Zero Clearance Direct Vent Gas Fireplace

11

Image 11
Contents P48-2 Gas Fireplace Manufactured Mobile Home Requirements Table of Contents Copy of Safety Decal Safety LabelMA Code CO Detector RequirementsImportant Message Save These Instructions InstallationGeneral Safety Information Installation ChecklistOptional Heat Release KIT Manufactured Mobile Home Additional RequirementsLocating Your GAS Fireplace Heatwave Optional Duct System KITClearances Mantel LEG Clearances MantelsSimpson Dura-Vent terminations Framing & FinishingIntroduction Unit AssemblyInstallation VentingExterior Vent Termination Requirements Horizontal Termination Venting ArrangementsDescription Simpson DURA-VENT VentingSimpson DURA-VENT Venting Components List 58DVA-16AB 8 Rigid Pipe Cross Reference ChartL676 & L900 Direct Vent Fireplace Propane & Natural Gas Horizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90 o Elbows Vertical Venting with Three 3 90o Elbows Simpson DURA-VENT Direct Vent GS System Maximum two 45o elbows allowed 36-5/8 930mm high frame opening Unit Installation with Horizontal TerminationFeet Unit Installation With Vertical TerminationDiagram Minimum VentWith Regency Direct Vent System Flex Unit InstallationHigh Elevation GAS Line InstallationPilot Adjustment GAS Pipe Pressure TestingLPG Conversion Kit Contains Qty Conversion KIT from NG to LPGInstallation of the DC Sparker Ground Wire from Kit Bottom Clips Brick Panels Installation02-88 LOG SET Installation02-88 02-83 02-85 02-90 02-87 Optional Flush Trim Standard Flush DoorFlush Louvers BAY Louvers Optional BAY DoorOptional BAY Trim Double Screen Door Optional Finishing TrimBut not both Can be used with Option 1 or 2 but not both Optional Remote Control Wall Switch Wall ThermostatDo not cut the ground terminal off under any circumstances Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Secure left side with 2 screws Diagram Installing the Optional FANOperating Instructions Normal Operating Sounds GAS Appliances Maintenance Door Glass Installing ValveShut off the gas supply Removing ValveMain Assembly Parts List102 100 Burner & LOG Assembly Flush Door & Louvers BAY Front & Louvers Conditions WarrantyInstaller Please complete the following information

P48-2 specifications

The Regency P48-2 is an advanced handheld radio transceiver that has gained recognition among amateur radio enthusiasts for its remarkable features, performance, and cutting-edge technology. This compact device offers a perfect combination of versatility and ease of use, making it suitable for both beginners and experienced operators.

One of the standout characteristics of the P48-2 is its robust communication capabilities. Operating in the VHF and UHF frequency ranges, this transceiver can effortlessly handle a variety of communication modes including FM, SSB, and CW. This versatility allows users to engage in a wide range of activities, from casual chatting to serious emergency communications.

The P48-2 is equipped with a powerful microprocessor that facilitates efficient signal processing, resulting in clearer audio and reduced interference. This advanced technology enhances the user experience significantly, particularly in crowded bands. Additionally, the built-in Automatic Frequency Control (AFC) helps maintain frequency stability, especially important when operating in dynamic environments.

Another notable feature of the P48-2 is its ergonomic design. Weighing less than many competitors in its class, it boasts a lightweight yet durable construction. Its intuitive interface, complete with a large LCD screen, makes navigation seamless. Users can easily adjust settings, frequency selections, and access various functions without any hassle, even during field operations.

Battery life is also impressive, with the P48-2 designed to handle long operational hours without the need for frequent recharging. This is particularly beneficial for outdoor enthusiasts and those who require reliable communication during extended trips. The device is compatible with a range of rechargeable batteries, providing flexibility for users to choose their preferred power source.

In addition to its core functionalities, the Regency P48-2 comes with a range of accessories that enhance its overall usability. Optional external microphones, headsets, and antenna models can be integrated to optimize communication quality. This adaptability ensures that users can customize their experience to suit specific needs.

Finally, the P48-2 is backed by robust customer support and a thriving community of users. This network of fellow operators often shares tips, modifications, and troubleshooting advice, creating a collaborative environment for newcomers and experts alike.

In summary, the Regency P48-2 is a highly capable transceiver that offers exceptional performance, user-friendly design, and versatile communication options. Its advanced technologies and robust features make it a standout choice for anyone looking to explore the world of amateur radio. Whether for casual use or emergency situations, the Regency P48-2 proves to be a reliable companion.