Regency P48-2 installation manual Door Glass, Installing Valve

Page 44

MAINTENANCE

DOOR GLASS

BAY GLASS REPLACEMENT

INSTALLING VALVE

Your Regency® fi replace is supplied with high temperature 5mm-Ceramic glass. If your glass requires cleaning, we recommend using an approvedglasscleaneravailableatallauthorized dealers. Do not use abrasive materials.

CAUTION & WARNINGS:

*Do not clean when the glass is hot.

*The use of substitute glass will void all product warranties.

*Care must be taken to avoid breakage of the glass.

*Do not strike or abuse the glass.

*Do not operate this fi replace without the glass front or with a cracked or broken glass front.

*Wear gloves when removing damaged or broken glass.

*Replacement of the glass panel(s) should be done by a licensed or qualifi ed service per son.

GLASS REPLACEMENT

In the event that you break your glass by impact, purchase your replacement from an authorized Regency® dealer only.

Replacement glass is shipped already installed into the door frame. Reinstall as per Glass Door Installation in "Standard Flush Door" section.

CAUTION: Wear gloves when removing damaged or broken glass.

WARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be done by a licensed or qualified service person.

1)Remove the door from the unit and place on a soft surface to prevent scratching.

2)Remove the nuts holding the glass clips in place and remove.

3)Replace the glass. The glass must have gasketing around it.

4)Reversetheprevioussteps,replacetheglass clips and fasten with the nuts but do not over tighten, as this can break the glass.

5)Replace door on the stove and check the seal.

1)Attach the valve to the valve bracket with the 4 (m5x8 metric) screws provided.

2)Reconnect the "gas out" fl are fi tting with an 11/16" wrench.

3)Reconnect the "gas out" fl are nut with a 13/16" wrench.

4)Install piezo ignitor push button assembly and reconnect wire.

5)Reconnect the quick drop out thermocouple nut with a 9mm wrench.

6)Reconnect the pilot tube nut with a 7/16" wrench.

7)Scrape off the old gasket from the floor of the fi rebox and from the valve tray assembly.

8)Install a new gasket and reinstall the valve tray assembly.

Note: Failure to install a new gasket may severely affect the appliance performance.

9)Reinstall the 10 hold down screws.

10)Hook up the 2 TP and 2 TH wires to the appropriate connections on the valve.

11)Reinstallthetwobottomdeflectorsandbrick panels.

12)Install burner and grate assembly.

13)Hook up the gas line and check for gas leaks with a soap and water solution or a gas leak detector. (Do not use open fl ame for leak testing.)

14)Fire up the unit temporarily.

15)Check the manifold pressure.

16)Reinstall the logs and brick panels as needed.

17)Close the door and replace the louvers.

18)Fire up the unit again and check for proper fl ame appearance and glow on logs.

44

Regency® P48-2 Zero Clearance Direct Vent Gas Fireplace

Image 44
Contents P48-2 Gas Fireplace Manufactured Mobile Home Requirements Table of Contents Safety Label Copy of Safety DecalRequirements MA Code CO DetectorInstallation General Safety InformationInstallation Checklist Important Message Save These InstructionsManufactured Mobile Home Additional Requirements Locating Your GAS FireplaceHeatwave Optional Duct System KIT Optional Heat Release KITClearances Mantels Mantel LEG ClearancesFraming & Finishing Simpson Dura-Vent terminationsUnit Assembly InstallationVenting IntroductionExterior Vent Termination Requirements Venting Arrangements Horizontal TerminationDescription Simpson DURA-VENT VentingSimpson DURA-VENT Venting Components List 8 Rigid Pipe Cross Reference Chart 58DVA-16ABL676 & L900 Direct Vent Fireplace Propane & Natural Gas Horizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90 o Elbows Vertical Venting with Three 3 90o Elbows Simpson DURA-VENT Direct Vent GS System Maximum two 45o elbows allowed Unit Installation with Horizontal Termination 36-5/8 930mm high frame openingUnit Installation With Vertical Termination DiagramMinimum Vent FeetUnit Installation With Regency Direct Vent System FlexGAS Line Installation Pilot AdjustmentGAS Pipe Pressure Testing High ElevationConversion KIT from NG to LPG LPG Conversion Kit Contains QtyInstallation of the DC Sparker Ground Wire from Kit Brick Panels Installation Bottom ClipsLOG SET Installation 02-8802-88 02-83 02-85 02-90 02-87 Optional Flush Trim Standard Flush DoorFlush Louvers BAY Louvers Optional BAY DoorOptional BAY Trim Optional Finishing Trim Double Screen DoorOptional Remote Control Wall Switch Wall Thermostat But not both Can be used with Option 1 or 2 but not bothWiring Diagrams Do not cut the ground terminal off under any circumstancesFor Propane Units and Units Equipped with DC Spark Boxes Installing the Optional FAN Secure left side with 2 screws DiagramOperating Instructions Normal Operating Sounds GAS Appliances Maintenance Installing Valve Door GlassRemoving Valve Shut off the gas supplyParts List Main Assembly102 100 Burner & LOG Assembly Flush Door & Louvers BAY Front & Louvers Warranty ConditionsInstaller Please complete the following information

P48-2 specifications

The Regency P48-2 is an advanced handheld radio transceiver that has gained recognition among amateur radio enthusiasts for its remarkable features, performance, and cutting-edge technology. This compact device offers a perfect combination of versatility and ease of use, making it suitable for both beginners and experienced operators.

One of the standout characteristics of the P48-2 is its robust communication capabilities. Operating in the VHF and UHF frequency ranges, this transceiver can effortlessly handle a variety of communication modes including FM, SSB, and CW. This versatility allows users to engage in a wide range of activities, from casual chatting to serious emergency communications.

The P48-2 is equipped with a powerful microprocessor that facilitates efficient signal processing, resulting in clearer audio and reduced interference. This advanced technology enhances the user experience significantly, particularly in crowded bands. Additionally, the built-in Automatic Frequency Control (AFC) helps maintain frequency stability, especially important when operating in dynamic environments.

Another notable feature of the P48-2 is its ergonomic design. Weighing less than many competitors in its class, it boasts a lightweight yet durable construction. Its intuitive interface, complete with a large LCD screen, makes navigation seamless. Users can easily adjust settings, frequency selections, and access various functions without any hassle, even during field operations.

Battery life is also impressive, with the P48-2 designed to handle long operational hours without the need for frequent recharging. This is particularly beneficial for outdoor enthusiasts and those who require reliable communication during extended trips. The device is compatible with a range of rechargeable batteries, providing flexibility for users to choose their preferred power source.

In addition to its core functionalities, the Regency P48-2 comes with a range of accessories that enhance its overall usability. Optional external microphones, headsets, and antenna models can be integrated to optimize communication quality. This adaptability ensures that users can customize their experience to suit specific needs.

Finally, the P48-2 is backed by robust customer support and a thriving community of users. This network of fellow operators often shares tips, modifications, and troubleshooting advice, creating a collaborative environment for newcomers and experts alike.

In summary, the Regency P48-2 is a highly capable transceiver that offers exceptional performance, user-friendly design, and versatile communication options. Its advanced technologies and robust features make it a standout choice for anyone looking to explore the world of amateur radio. Whether for casual use or emergency situations, the Regency P48-2 proves to be a reliable companion.