Page 5

REQUIREMENTS

MA Code - CO Detector

(for the State of Massachusetts only)

5.08: Modifications to NFPA-54, Chapter 10

(2) Revise 10.8.3 by adding the following additional requirements:

(a)For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

1.INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors

a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

2.APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

3.SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight

(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL

OBSTRUCTIONS".

4.INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

1.The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by the Board; and

2.Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.

(c)MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

1.Detailed instructions for the installation of the venting system design or the venting system components; and

2.A complete parts list for the venting system design or venting system.

(d)MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies "special venting systems", the following requirements shall be satisfied by the manufacturer:

1.The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and

2.The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.

(e)A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

Regency® P48-2 Zero Clearance Direct Vent Gas Fireplace

5

Image 5
Contents P48-2 Gas Fireplace Manufactured Mobile Home Requirements Table of Contents Copy of Safety Decal Safety LabelMA Code CO Detector RequirementsGeneral Safety Information InstallationInstallation Checklist Important Message Save These InstructionsLocating Your GAS Fireplace Manufactured Mobile Home Additional RequirementsHeatwave Optional Duct System KIT Optional Heat Release KITClearances Mantel LEG Clearances MantelsSimpson Dura-Vent terminations Framing & FinishingInstallation Unit AssemblyVenting IntroductionExterior Vent Termination Requirements Horizontal Termination Venting ArrangementsDescription Simpson DURA-VENT VentingSimpson DURA-VENT Venting Components List 58DVA-16AB 8 Rigid Pipe Cross Reference ChartL676 & L900 Direct Vent Fireplace Propane & Natural Gas Horizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90 o Elbows Vertical Venting with Three 3 90o Elbows Simpson DURA-VENT Direct Vent GS System Maximum two 45o elbows allowed 36-5/8 930mm high frame opening Unit Installation with Horizontal TerminationDiagram Unit Installation With Vertical TerminationMinimum Vent FeetWith Regency Direct Vent System Flex Unit InstallationPilot Adjustment GAS Line InstallationGAS Pipe Pressure Testing High ElevationLPG Conversion Kit Contains Qty Conversion KIT from NG to LPGInstallation of the DC Sparker Ground Wire from Kit Bottom Clips Brick Panels Installation02-88 LOG SET Installation02-88 02-83 02-85 02-90 02-87 Optional Flush Trim Standard Flush DoorFlush Louvers BAY Louvers Optional BAY DoorOptional BAY Trim Double Screen Door Optional Finishing TrimBut not both Can be used with Option 1 or 2 but not both Optional Remote Control Wall Switch Wall ThermostatDo not cut the ground terminal off under any circumstances Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Secure left side with 2 screws Diagram Installing the Optional FANOperating Instructions Normal Operating Sounds GAS Appliances Maintenance Door Glass Installing ValveShut off the gas supply Removing ValveMain Assembly Parts List102 100 Burner & LOG Assembly Flush Door & Louvers BAY Front & Louvers Conditions WarrantyInstaller Please complete the following information

P48-2 specifications

The Regency P48-2 is an advanced handheld radio transceiver that has gained recognition among amateur radio enthusiasts for its remarkable features, performance, and cutting-edge technology. This compact device offers a perfect combination of versatility and ease of use, making it suitable for both beginners and experienced operators.

One of the standout characteristics of the P48-2 is its robust communication capabilities. Operating in the VHF and UHF frequency ranges, this transceiver can effortlessly handle a variety of communication modes including FM, SSB, and CW. This versatility allows users to engage in a wide range of activities, from casual chatting to serious emergency communications.

The P48-2 is equipped with a powerful microprocessor that facilitates efficient signal processing, resulting in clearer audio and reduced interference. This advanced technology enhances the user experience significantly, particularly in crowded bands. Additionally, the built-in Automatic Frequency Control (AFC) helps maintain frequency stability, especially important when operating in dynamic environments.

Another notable feature of the P48-2 is its ergonomic design. Weighing less than many competitors in its class, it boasts a lightweight yet durable construction. Its intuitive interface, complete with a large LCD screen, makes navigation seamless. Users can easily adjust settings, frequency selections, and access various functions without any hassle, even during field operations.

Battery life is also impressive, with the P48-2 designed to handle long operational hours without the need for frequent recharging. This is particularly beneficial for outdoor enthusiasts and those who require reliable communication during extended trips. The device is compatible with a range of rechargeable batteries, providing flexibility for users to choose their preferred power source.

In addition to its core functionalities, the Regency P48-2 comes with a range of accessories that enhance its overall usability. Optional external microphones, headsets, and antenna models can be integrated to optimize communication quality. This adaptability ensures that users can customize their experience to suit specific needs.

Finally, the P48-2 is backed by robust customer support and a thriving community of users. This network of fellow operators often shares tips, modifications, and troubleshooting advice, creating a collaborative environment for newcomers and experts alike.

In summary, the Regency P48-2 is a highly capable transceiver that offers exceptional performance, user-friendly design, and versatile communication options. Its advanced technologies and robust features make it a standout choice for anyone looking to explore the world of amateur radio. Whether for casual use or emergency situations, the Regency P48-2 proves to be a reliable companion.