Regency P48-2 Installation, Important Message Save These Instructions, Before YOU Start

Page 6

INSTALLATION

IMPORTANT MESSAGE

SAVE THESE

INSTRUCTIONS

The P48-NG2/P48-LP2 Direct Vent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fi replace is installed in compliance with manufacturers instructions and all applicable codes.

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE.

CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPE- CIALLY THE FIREPLACE GLASS, AND SHOULD STAYAWAYTOAVOIDBURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

CLOTHING OR OTHER FLAMMABLE MATERIALSHOULDNOTBEPLACED ON OR NEAR THE APPLIANCE.

GENERAL SAFETY

INFORMATION

1)The appliance installation must conform with local codes or, in the absence of local codes, with the current Canadian or National Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes.

2)The appliance when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code.

3)See general construction and assembly instructions. The appliance and vent should be enclosed.

4)This appliance must be connected to the specifi ed vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fi tted as per Venting instructions.

5)Inspect the venting system annually for blockage and any signs of deterioration.

6)Venting terminals shall not be recessed into a wall or siding.

7)Any safety glass removed for servicing must be replaced prior to operating the appliance.

8)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fi replace.

9)Wearglovesandsafetyglassesforprotection while doing required maintenance.

10)Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination.

11)Under no circumstances should this appliance be modifi ed. Parts that have to be removed for servicing should be replaced prior to operating this appliance.

12)Installation and any repairs to this appliance should be done by an authorized service person.Aprofessionalservicepersonshould be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.

13)Do not slam shut or strike the glass door.

14)Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

15)The appliance area must be kept clear and free of combustible materials, (gases and other fl ammable vapours and liquids).

Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

INSTALLATION

CHECKLIST

1)Locate appliance

a)Room location (Refer to "Locating Your Gas fi replace" section)

b)Clearances to Combustibles (Refer to "Clearances" section)

c)MantleClearances(Referto"Combustible Mantel Clearances" section)

d)Framing&FinishingRequirements(Refer to "Framing & Finishing" section)

e)Venting Requirements (Refer to "Venting" section)

2)Assemble Top Standoffs and Top Facing Support and Side Nailing Strips (Refer to "UnitAssembly Prior to Installation). NOTE: Must be done before installing unit into place.

3)Install vent (Refer to "Venting Arrangement" sections).

4)Make gas and electrical connections. Test the pilot. Must be as per diagram (Refer to "Pilot Adjustment " section).

Convert to propane if desired (Refer to "Conversion from NG to LPG" section).

5)Test Gas Pressure. (Refer to "Gas Pipe Pressure Testing" section)

6

Regency® P48-2 Zero Clearance Direct Vent Gas Fireplace

Image 6
Contents P48-2 Gas Fireplace Manufactured Mobile Home Requirements Table of Contents Safety Label Copy of Safety DecalRequirements MA Code CO DetectorInstallation Checklist InstallationGeneral Safety Information Important Message Save These InstructionsHeatwave Optional Duct System KIT Manufactured Mobile Home Additional RequirementsLocating Your GAS Fireplace Optional Heat Release KITClearances Mantels Mantel LEG ClearancesFraming & Finishing Simpson Dura-Vent terminationsVenting Unit AssemblyInstallation IntroductionExterior Vent Termination Requirements Venting Arrangements Horizontal TerminationSimpson DURA-VENT Venting Simpson DURA-VENT Venting Components ListDescription 8 Rigid Pipe Cross Reference Chart 58DVA-16ABL676 & L900 Direct Vent Fireplace Propane & Natural Gas Horizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90 o Elbows Vertical Venting with Three 3 90o Elbows Simpson DURA-VENT Direct Vent GS System Maximum two 45o elbows allowed Unit Installation with Horizontal Termination 36-5/8 930mm high frame openingMinimum Vent Unit Installation With Vertical TerminationDiagram FeetUnit Installation With Regency Direct Vent System FlexGAS Pipe Pressure Testing GAS Line InstallationPilot Adjustment High ElevationConversion KIT from NG to LPG LPG Conversion Kit Contains QtyInstallation of the DC Sparker Ground Wire from Kit Brick Panels Installation Bottom ClipsLOG SET Installation 02-8802-88 02-83 02-85 02-90 02-87 Standard Flush Door Flush LouversOptional Flush Trim Optional BAY Door Optional BAY TrimBAY Louvers Optional Finishing Trim Double Screen DoorOptional Remote Control Wall Switch Wall Thermostat But not both Can be used with Option 1 or 2 but not bothWiring Diagrams Do not cut the ground terminal off under any circumstancesFor Propane Units and Units Equipped with DC Spark Boxes Installing the Optional FAN Secure left side with 2 screws DiagramOperating Instructions Normal Operating Sounds GAS Appliances Maintenance Installing Valve Door GlassRemoving Valve Shut off the gas supplyParts List Main Assembly102 100 Burner & LOG Assembly Flush Door & Louvers BAY Front & Louvers Warranty ConditionsInstaller Please complete the following information

P48-2 specifications

The Regency P48-2 is an advanced handheld radio transceiver that has gained recognition among amateur radio enthusiasts for its remarkable features, performance, and cutting-edge technology. This compact device offers a perfect combination of versatility and ease of use, making it suitable for both beginners and experienced operators.

One of the standout characteristics of the P48-2 is its robust communication capabilities. Operating in the VHF and UHF frequency ranges, this transceiver can effortlessly handle a variety of communication modes including FM, SSB, and CW. This versatility allows users to engage in a wide range of activities, from casual chatting to serious emergency communications.

The P48-2 is equipped with a powerful microprocessor that facilitates efficient signal processing, resulting in clearer audio and reduced interference. This advanced technology enhances the user experience significantly, particularly in crowded bands. Additionally, the built-in Automatic Frequency Control (AFC) helps maintain frequency stability, especially important when operating in dynamic environments.

Another notable feature of the P48-2 is its ergonomic design. Weighing less than many competitors in its class, it boasts a lightweight yet durable construction. Its intuitive interface, complete with a large LCD screen, makes navigation seamless. Users can easily adjust settings, frequency selections, and access various functions without any hassle, even during field operations.

Battery life is also impressive, with the P48-2 designed to handle long operational hours without the need for frequent recharging. This is particularly beneficial for outdoor enthusiasts and those who require reliable communication during extended trips. The device is compatible with a range of rechargeable batteries, providing flexibility for users to choose their preferred power source.

In addition to its core functionalities, the Regency P48-2 comes with a range of accessories that enhance its overall usability. Optional external microphones, headsets, and antenna models can be integrated to optimize communication quality. This adaptability ensures that users can customize their experience to suit specific needs.

Finally, the P48-2 is backed by robust customer support and a thriving community of users. This network of fellow operators often shares tips, modifications, and troubleshooting advice, creating a collaborative environment for newcomers and experts alike.

In summary, the Regency P48-2 is a highly capable transceiver that offers exceptional performance, user-friendly design, and versatile communication options. Its advanced technologies and robust features make it a standout choice for anyone looking to explore the world of amateur radio. Whether for casual use or emergency situations, the Regency P48-2 proves to be a reliable companion.