Regency P121RC-NG, P131-NG, P121LC-NG Framing and Finishing, P121 See Thru Framing Dimensions

Page 10

INSTALLATION

FRAMING AND FINISHING

1)For ease of installation, frame your fireplace after it is positioned and the flue system is installed. Remember to install the top standoffs. See page 11 for assembly. Use 2x4's and frame to local building codes.

CAUTION: Verify your fireplace dimensions, framing methods and finished wall facing details before framing. Determine the total thickness of facing material - drywall plus ceramic tiles, slate, etc. Allow the finish surface to be flush with the front or side of the unit. Total facing thickness can vary from 1/2" (13mm) to 1-1/4" (32mm) thick.

2)When locating your appliance on an exterior wall or in a chase, apply a vapour barrier and drywall, as per local building codes. DO NOT

INSULATE THE FIREPLACE ITSELF.

CAUTION: The unit does not have to be completely enclosed in a chase. The clearance on top of the unit is 0" to the standoffs so combustible building materials can be laid directly on top of the standoffs. You must maintain clearance from the flue to combustible materials for both rigid and flex, see Flue Clear- ances, page 9.

P121 - See Thru

Framing Dimensions

 

P121 (See Thru)

P131 (Pier)

P121LC / P121RC

 

 

 

(Corner Unit)

A

25"(635mm)

25"(635mm)

26-13/13"(660mm)

 

minus two times

minus two times

minus two times

 

the finishing

the finishing

the finishing

 

material thickness*

material thickness*

material thickness*

B

42-1/2"(1080mm)

42-1/2"(1080mm)

42-1/2"(1080mm)

C

46-3/4"(1187mm)

45" (1143mm)

45"(1143mm)

 

 

minus one time

minus one time

 

 

the finishing

the finishing

 

 

material thickness*

material thickness*

* Finish material thickness includes: drywall, ceramic tile, slate, etc.

P121LC - Corner Unit

P131 - Pier

P121RC - Corner Unit

C

A

B

Note: These units are non-load bearing.

10

Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace

Image 10
Contents Manual Please Keep These Instructions For Future ReferenceCongratulations To the New OwnerTable of Contents Safety Label Installation Checklist InstallationGeneral Safety Information Save These InstructionsSpecifications P121 See Thru P131 PierP121LC Left Corner Unit P121RC Right Corner Unit Locating Your GAS Fireplace Clearances Combustible MantelsFraming and Finishing P121 See Thru Framing DimensionsP121LC Corner Unit P131 Pier P121RC Corner Unit Facing & Finishing Requirements Unit Assembly Prior to InstallationTop Standoff Assembly Flueing IntroductionExterior Flue Termination Locations Clearance k in mmFlueing Arrangement Horizontal Terminations Simpson DURA-VENT Flueing Simpson DURA-VENT Flueing Components ListFlueing Arrangements Horizontal Terminations Simpson DURA-VENT Direct Vent GS System LPG & NGHorizontal Flueing with Two 2 90o Elbows Horizontal Flueing with Three 3 90o ElbowsFlueing Arrangements Vertical Terminations Vertical Flueing with Two 2 90o Elbows Vertical Flueing with Three 3 90o ElbowsHorizontal Installations Vent GS systemWhere the flue will pene Vertical TerminationOffset Chart Installation ProceduresFor Regency AstroCapTM Direct Flue System Flex Burner Orifice GAS Pipe Pressure Testing Pilot AdjustmentGAS Line Installation P121/P121LC/P121RC/P131-NG System DataLOG Installation 3-digit numbers ie are molded into the rear of each log327 Glass Door Removal Finishing Trim Louvers & Grills Slide Trim into Slot Push trim tight against magnetRemote Control Thermostat Wire TableWiring Diagram Terminal Block LocationOperating Instructions General Flue Maintenance Maintenance InstructionsCopy of the Lighting Plate Instructions Maintenance Installing Valve Parts List P121 see Thru Main AssemblyP131 Pier Main Assembly P121RC Right Corner Main Assembly P121LC Left Corner Main Assembly P121/P121LC/P121RC/P131 Burner Assembly & LOG SET Page Conditions WarrantyWarranty Lifetime Exclusions

P121RC-NG, P131-NG, P121LC-NG, P121-NG specifications

The Regency P131-NG, P121LC-NG, P121RC-NG, and P121-NG are a series of advanced communication devices designed to set new standards in the realm of radio technology, especially for industrial and commercial applications. These devices are engineered to provide reliable performance, exceptional clarity, and robust features that cater to the diverse needs of users in various sectors.

One of the standout features of the Regency P131-NG and its counterparts is their enhanced communication range. Utilizing advanced digital signal processing technology, these radios ensure clear audio transmission even in challenging environments. This capability is crucial for users operating in areas with significant interference or in remote locations, where traditional radios may fail to maintain a stable connection.

The devices also boast a rugged design, tailored for durability and resistance to environmental factors. With an IP67 rating, the P131-NG series is protected against dust and can withstand immersion in water, making it ideal for outdoor use. The robust build quality ensures that these radios can endure the rigors of everyday use in industrial settings.

In terms of user interface, the P121LC-NG and P121RC-NG are equipped with intuitive controls that facilitate ease of use. The large display screen offers clear visibility of channel information and battery status, while the customizable buttons allow users to quickly access their most-used functions. Additionally, these models feature programmable channels, enabling users to tailor their communication needs effectively.

Battery life is another key characteristic of these radios. The devices are designed with energy efficiency in mind, offering extended use between charges. This is complemented by rapid charging technology, which ensures that downtime is minimized, allowing users to stay connected when it matters most.

Additionally, the inclusion of advanced security features is noteworthy. The P131-NG series incorporates encryption capabilities that safeguard sensitive communications, making them an excellent choice for organizations concerned about data security.

Overall, the Regency P131-NG, P121LC-NG, P121RC-NG, and P121-NG stand out in the crowded market of communication devices by offering a combination of superior range, robust construction, user-friendly interfaces, long battery life, and enhanced security features. These radios are poised to meet the demands of a wide array of users, from industrial workers to commercial enterprises, providing reliable communication solutions in any environment.