OPERATING INSTRUCTIONS

COPY OF THE LIGHTING PLATE INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

This appliance must be installed in accordance with local codes, if any; if not, follow the current CAN1-B149/ANSI Z 223.1 (Australia: AS5601-2004, New Zealand: NZS 5261)

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss oflife.Improperinstallation,adjustment,alteration,serviceormaintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or gas supplier.

A)This appliance has a pilot which

C)Use only your hand to push in or turn

must be lighted by hand. When

the gas control knob. Never use tools.

lighting the pilot, follow these

If the knob will not push in or turn by

instructions exactly.

hand, don’t try to repair it, call a

 

qualified service technician. Force or

B)BEFORE LIGHTING smell all around

attempted repair may result in a fire

the appliance area for gas. Be sure

or explosion.

to smell next to the floor because

 

some gas is heavier than air and

D)Do not use this appliance if any part

will settle on the floor.

has been under water. Immediately

 

call a qualified service technician to

WHAT TO DO IF YOU SMELL GAS

inspect the appliance and to replace

- Do not try to light any appliance

any part of the control system and any

- Do not touch any electric switch, do

gas control which has been under

not use any phone in your building

water.

- Immediately call your gas supplier

 

from a neighbours phone. Follow

This appliance needs fresh air for safe

the gas supplier’s instructions.

operation and must be installed so there

-If you cannot reach your gas are provisions for adequate combustion supplier, call the fire department. and ventilation air.

CAUTION:Hotwhileinoperation.Donottouch.SevereBurnsmayresult.Due to high surface temperatures keep children, clothing and furniture, gasoline and other liquids having fammable vapors away. Keep burner and control compartment clean. See installation and operating instructions

accompanying appliance.

LIGHTING INSTRUCTIONS

STOP! Read the safety information above on this label.

1)Push in gas control knob slightly and turn to “PILOT” position.

2)Push in control knob all the way and hold in until the pilot lights up. Continue to hold the control knob in for about 20 seconds after the pilot is lit. Release knob.

3)Push in gas control knob slightly and

turn to "ON" position.

Gas Inlet

4) Turn ON the flame switch.

TO TURN OFF GAS APPLIANCE

You may shut off the pilot during prolonged non use periods to conserve fuel.

1)Turn OFF the flame switch.

2)Push in gas control knob slightly and turn to "OFF" position.

DO NOT REMOVE THIS INSTRUCTION PLATE

918-253a

MAINTENANCE

INSTRUCTIONS

1)Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacu- uming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged.

2)Clean appliance and door with a damp cloth (never when unit is hot). Never use an abrasive cleaner. The glass should be cleaned with a gas fireplace glass cleaner.

The glass should be cleaned when it starts looking cloudy.

3)The heater is finished in a heat resistant paint and should only be refinished with heat resistant paint. Regency uses Stove- Bright Paint - Metallic Black #6309.

4)Make a periodic check of burner for proper position and condition. Visually check the flame of the burner periodically, making sure the flames are steady; not lifting or floating. If there is a problem, call a author- ized service person.

5)The appliance and flueing system must be inspected before use, and at least annual- ly, by a authorized field service person, to ensure that the flow of combustion and ventilation air is not obstructed.

Note: Never operate the appliance with- out the glass properly secured in place.

6)Do not use this appliance if any part has been under water. Immediately call a au- thorized service technician to inspect the appliance and to replace nay part of the control system and any gas control which has been under water.

7)In the event this appliance has been serv- iced check that the flue-air system has been properly resealed & reinstalled in accordance with the manufacturer's in- structions.

8)Verify operation after servicing.

General Flue Maintenance

Conduct an inspection of the flueing system semi-annually. Recommended areas to inspect as follows:

1)Check the Flueing System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes. These com- ponents should be replaced immediately.

30

Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace

Image 30
Contents Manual Please Keep These Instructions For Future ReferenceCongratulations To the New OwnerTable of Contents Safety Label Installation Checklist InstallationGeneral Safety Information Save These InstructionsSpecifications P121 See Thru P131 PierP121LC Left Corner Unit P121RC Right Corner Unit Locating Your GAS Fireplace Clearances Combustible MantelsP121 See Thru Framing Dimensions Framing and FinishingP121LC Corner Unit P131 Pier P121RC Corner Unit Facing & Finishing Requirements Unit Assembly Prior to InstallationTop Standoff Assembly Flueing IntroductionExterior Flue Termination Locations Clearance k in mmFlueing Arrangement Horizontal Terminations Simpson DURA-VENT Flueing Simpson DURA-VENT Flueing Components ListFlueing Arrangements Horizontal Terminations Simpson DURA-VENT Direct Vent GS System LPG & NGHorizontal Flueing with Two 2 90o Elbows Horizontal Flueing with Three 3 90o ElbowsFlueing Arrangements Vertical Terminations Vertical Flueing with Two 2 90o Elbows Vertical Flueing with Three 3 90o ElbowsHorizontal Installations Vent GS systemWhere the flue will pene Vertical TerminationInstallation Procedures Offset ChartFor Regency AstroCapTM Direct Flue System Flex Burner Orifice GAS Pipe Pressure Testing Pilot AdjustmentGAS Line Installation P121/P121LC/P121RC/P131-NG System DataLOG Installation 3-digit numbers ie are molded into the rear of each log327 Glass Door Removal Finishing Trim Louvers & Grills Slide Trim into Slot Push trim tight against magnetRemote Control Thermostat Wire TableWiring Diagram Terminal Block LocationOperating Instructions Maintenance Instructions General Flue MaintenanceCopy of the Lighting Plate Instructions Maintenance Installing Valve Parts List P121 see Thru Main AssemblyP131 Pier Main Assembly P121RC Right Corner Main Assembly P121LC Left Corner Main Assembly P121/P121LC/P121RC/P131 Burner Assembly & LOG SET Page Conditions WarrantyWarranty Lifetime Exclusions

P121RC-NG, P131-NG, P121LC-NG, P121-NG specifications

The Regency P131-NG, P121LC-NG, P121RC-NG, and P121-NG are a series of advanced communication devices designed to set new standards in the realm of radio technology, especially for industrial and commercial applications. These devices are engineered to provide reliable performance, exceptional clarity, and robust features that cater to the diverse needs of users in various sectors.

One of the standout features of the Regency P131-NG and its counterparts is their enhanced communication range. Utilizing advanced digital signal processing technology, these radios ensure clear audio transmission even in challenging environments. This capability is crucial for users operating in areas with significant interference or in remote locations, where traditional radios may fail to maintain a stable connection.

The devices also boast a rugged design, tailored for durability and resistance to environmental factors. With an IP67 rating, the P131-NG series is protected against dust and can withstand immersion in water, making it ideal for outdoor use. The robust build quality ensures that these radios can endure the rigors of everyday use in industrial settings.

In terms of user interface, the P121LC-NG and P121RC-NG are equipped with intuitive controls that facilitate ease of use. The large display screen offers clear visibility of channel information and battery status, while the customizable buttons allow users to quickly access their most-used functions. Additionally, these models feature programmable channels, enabling users to tailor their communication needs effectively.

Battery life is another key characteristic of these radios. The devices are designed with energy efficiency in mind, offering extended use between charges. This is complemented by rapid charging technology, which ensures that downtime is minimized, allowing users to stay connected when it matters most.

Additionally, the inclusion of advanced security features is noteworthy. The P131-NG series incorporates encryption capabilities that safeguard sensitive communications, making them an excellent choice for organizations concerned about data security.

Overall, the Regency P131-NG, P121LC-NG, P121RC-NG, and P121-NG stand out in the crowded market of communication devices by offering a combination of superior range, robust construction, user-friendly interfaces, long battery life, and enhanced security features. These radios are poised to meet the demands of a wide array of users, from industrial workers to commercial enterprises, providing reliable communication solutions in any environment.