Regency P121-NG, P131-NG Facing & Finishing Requirements, Unit Assembly Prior to Installation

Page 11

INSTALLATION

FACING & FINISHING REQUIREMENTS

This fireplace is supplied with a 3" metal extension trim above the fireplace. The extension trim may be replaced if the framing is faced with a non- combustible material placed flush with the front and side face of the unit and extending from the top of the unit. (ie. tile, slate, etc.)

UNIT ASSEMBLY

PRIOR TO

INSTALLATION

The 4 Top Standoffs must be correctly positioned and attached to the top before unit is slipped into position.

Top Standoff Assembly

The top standoffs are shipped in a flat position and must be folded into shape and attached.

1) Remove the standoffs from the fireplace top.

2) Take each standoff and bend into the correct shape. Bend up at the bend lines until the screw holes in the standoff and the pre-punched screw holes on the fireplace top line up.

3) Attach the standoff securely to the top with

4 screws per standoff (on opposite cor- ners).

FLUEING

INTRODUCTION

The P121/P121LC/P121RC/P131 uses the "balanced flue" technology Co Axial system. The inner liner flue products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.

Note: These flue pipes must not be con- nected to any other appliance.

The gas appliance and flue system must be flueed directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct flue gas appliance must use it's own separate flue system. Common flue sys- tems are prohibited.

Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace

11

Image 11
Contents Please Keep These Instructions For Future Reference ManualTo the New Owner CongratulationsTable of Contents Safety Label Save These Instructions InstallationGeneral Safety Information Installation ChecklistP121 See Thru P131 Pier SpecificationsP121LC Left Corner Unit P121RC Right Corner Unit Locating Your GAS Fireplace Combustible Mantels ClearancesP121LC Corner Unit P131 Pier P121RC Corner Unit P121 See Thru Framing DimensionsFraming and Finishing Flueing Introduction Unit Assembly Prior to InstallationTop Standoff Assembly Facing & Finishing RequirementsClearance k in mm Exterior Flue Termination LocationsFlueing Arrangement Horizontal Terminations Simpson DURA-VENT Flueing Components List Simpson DURA-VENT FlueingSimpson DURA-VENT Direct Vent GS System LPG & NG Flueing Arrangements Horizontal TerminationsHorizontal Flueing with Three 3 90o Elbows Horizontal Flueing with Two 2 90o ElbowsFlueing Arrangements Vertical Terminations Vertical Flueing with Three 3 90o Elbows Vertical Flueing with Two 2 90o ElbowsVent GS system Horizontal InstallationsVertical Termination Where the flue will peneFor Regency AstroCapTM Direct Flue System Flex Installation ProceduresOffset Chart Burner Orifice P121/P121LC/P121RC/P131-NG System Data Pilot AdjustmentGAS Line Installation GAS Pipe Pressure Testing3-digit numbers ie are molded into the rear of each log LOG Installation327 Slide Trim into Slot Push trim tight against magnet Glass Door Removal Finishing Trim Louvers & GrillsThermostat Wire Table Remote ControlTerminal Block Location Wiring DiagramOperating Instructions Copy of the Lighting Plate Instructions Maintenance InstructionsGeneral Flue Maintenance Maintenance Installing Valve P121 see Thru Main Assembly Parts ListP131 Pier Main Assembly P121RC Right Corner Main Assembly P121LC Left Corner Main Assembly P121/P121LC/P121RC/P131 Burner Assembly & LOG SET Page Exclusions WarrantyWarranty Lifetime Conditions

P121RC-NG, P131-NG, P121LC-NG, P121-NG specifications

The Regency P131-NG, P121LC-NG, P121RC-NG, and P121-NG are a series of advanced communication devices designed to set new standards in the realm of radio technology, especially for industrial and commercial applications. These devices are engineered to provide reliable performance, exceptional clarity, and robust features that cater to the diverse needs of users in various sectors.

One of the standout features of the Regency P131-NG and its counterparts is their enhanced communication range. Utilizing advanced digital signal processing technology, these radios ensure clear audio transmission even in challenging environments. This capability is crucial for users operating in areas with significant interference or in remote locations, where traditional radios may fail to maintain a stable connection.

The devices also boast a rugged design, tailored for durability and resistance to environmental factors. With an IP67 rating, the P131-NG series is protected against dust and can withstand immersion in water, making it ideal for outdoor use. The robust build quality ensures that these radios can endure the rigors of everyday use in industrial settings.

In terms of user interface, the P121LC-NG and P121RC-NG are equipped with intuitive controls that facilitate ease of use. The large display screen offers clear visibility of channel information and battery status, while the customizable buttons allow users to quickly access their most-used functions. Additionally, these models feature programmable channels, enabling users to tailor their communication needs effectively.

Battery life is another key characteristic of these radios. The devices are designed with energy efficiency in mind, offering extended use between charges. This is complemented by rapid charging technology, which ensures that downtime is minimized, allowing users to stay connected when it matters most.

Additionally, the inclusion of advanced security features is noteworthy. The P131-NG series incorporates encryption capabilities that safeguard sensitive communications, making them an excellent choice for organizations concerned about data security.

Overall, the Regency P131-NG, P121LC-NG, P121RC-NG, and P121-NG stand out in the crowded market of communication devices by offering a combination of superior range, robust construction, user-friendly interfaces, long battery life, and enhanced security features. These radios are poised to meet the demands of a wide array of users, from industrial workers to commercial enterprises, providing reliable communication solutions in any environment.