Regency P121/P131-NG2, P121/P131-LP2 Regency Direct Vent System Flex, Snorkel Terminations

Page 3

Gas Fireplaces

Regency Direct Vent System (Flex)

Horizontal Terminations Only

These venting systems, in combination with the P121/P131 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram.

FPI Direct Vent (Flex) System Termination Kits include all the parts needed to install the P42 using a flexible vent.

FPI Kit #

Length

Contains:

#946-513

2 Feet

1)

6-5/8” fl exible liner (Kit length)

 

 

2)

4” fl exible liner (Kit length)

 

 

3)

spring spacers (3)

#946-515

4 Feet

4)

thimble (2)

 

 

5)

AstroCap termination cap (1)

 

 

6)

screws (12)

#946-516

10 Feet

7)

tube of Mill Pac (1)

 

 

8)

plated screws (8)

 

 

9)

S.S. screws #8 x 1-1/2” drill point, (4)

Notes:

1)Liner sections should be continuous without any joints or seams.

2)Only Flex pipe purchased from Regency may be used for Flex installations.

3)Horizontal sections must be supported every 3 feet.

P121-P131 Gas Fireplace

Snorkel Terminations

Snorkel Terminations:

For installations requiring a vertical rise on the exterior of the building, 14-inch and 36-inch tall Snorkel Terminations and the Riser Vent are available. Follow the same installation procedures as used for standard Horizontal Termination. NEVER install the snorkel upside down.

Riser Vent

Termination

Dura-Vent

Snorkel

Min. 12"*

(305mm)

Min. 6-1/4"*

(159mm)

Below Grade Snorkel Installation (Dura-Vent Only)

If the Snorkel Termination must be installed below grade, i.e. basement application, proper drainage must be provided to prevent water from entering the Snorkel Termination. Refer to Rigid Pipe Installation instructions for details. Do not attempt to enclose the Snorkel within the wall, or any other type of enclosure.

Gas Fireplaces

Alternate Horizontal

Termination Caps

Alternate:

Horizontal

Riser Vent

Terminal

Part# 640-530/P

June 2007 Regency Product Specifications Book

Dura-Vent

Snorkel

Min. 12"* (305mm)

Window

Well

Adequate drainage

Gravel

71

Image 3
Contents Model P121/P131-NG2 P121/P131-LP2 June 2007 Regency Product Specifications BookApproved Venting Systems Combustible Mantels Framing and FinishingClearance Requirements Parallel Wall ClearancesHorizontal Terminations Only Below Grade Snorkel Installation Dura-Vent OnlyRegency Direct Vent System Flex Snorkel TerminationsHorizontal or Vertical Terminations Rigid Pipe VentingVenting Arrangements Vertical Terminations Vertical Venting with One 1 90 ElbowOption + H1 Horizontal Venting with One 1 90 Elbow Venting Arrangements Horizontal TerminationsOption + H1 + H2